User manual SUB-ZERO SRT INSTALL GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SUB-ZERO SRT INSTALL GUIDE. We hope that this SUB-ZERO SRT INSTALL GUIDE user guide will be useful to you.


SUB-ZERO SRT INSTALL GUIDE : Download the complete user guide (249 Ko)

Manual abstract: user guide SUB-ZERO SRT INSTALL GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] S EALED B URNER R ANGETOPS INSTALLATION INSTRUCTIONS As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equipment. There are two types of potential hazards that may occur during installation. signals a situation where minor injury or product damage may occur if you do not follow instructions. states a hazard that may cause serious injury or death if precautions are not followed. Another footnote we would like to identify is IMPORTANT NOTE: This highlights information that is especially relevant to a problemfree installation. WOLF ® is a registered trademark of Wolf Appliance Company, LLC W O L F S E A L E D B U R N E R R A N G E TO P I N S TA L L AT I O N R E Q U I R E M E N T S IMPORTANT NOTE: This installation must be completed by a qualified installer, service agency or gas supplier. IMPORTANT NOTE: Save these Installation Instructions for the local inspector's use. [. . . ] Charbroiler (C) Models: 44" (1118) minimum vertical distance from countertop to combustible materials above the rangetop. I S L A N D | P E N I N S U L A I N S T A L L AT I O N S Minimum clearances to combustible surfaces: Island Installations: Minimum 12" (305) clearance to rear wall that rises above the countertop. Peninsula Installations: Minimum 6" (152) clearance to side walls and minimum 12" (305) clearance to rear wall that rises above the countertop. Refer to the Installation Specifications illustration for your model on pages 7­ 9 for the exact rough opening dimensions. Failure to locate the rangetop without the proper clearances will result in a fire hazard. RISER REQUIREMENTS Installations against a combustible surface: Model SRT304: No riser requirements. 36" (914) Sealed Burner Rangetops: A minimum 5" (127) riser is required when installing Model SRT366 against a combustible surface. A minimum 10" (254) riser is required for all charbroiler (C) or griddle (G) models installed against a combustible surface. 48" (1219) Sealed Burner Rangetops: A minimum 10" (254) riser is required for all charbroiler (C) or griddle (G) models installed against a combustible surface. 6 I N S TA L L AT I O N I N S T R U C T I O N S 30" (762) S E A L E D B U R N E R R A N G E TO P 28 1/2" (724) OVERALL DEPTH 9 1/4" (235) 27 1/2" (699) WITH 20" RISER (445) (318) WITH 10" WITH 5" RISER RISER OVERALL DIMENSIONS Overall Width Overall Height (to cooking surface) Overall Depth 29 7/8" (759) 8 1/2" (216) 28 1/2" (724) 30" (762) COOKING SURFACE 12 1/2" 17 1/2" 8 1/2" (216) OVERALL HEIGHT 7 1/2" (191) 29 7/8" (759) OVERALL WIDTH 24 1/4" (616) Opening Width Dimensions may vary to ± 1/8" (3). I N S TA L L A T I O N S P E C I F I C A T I O N S VENTILATION HOOD 30"min (762) COUNTERTOP TO COMBUSTIBLE MATERIALS 30"min (762) TO 36"max (914) TO BOTTOM OF VENTILATION HOOD 18"min (457) TO COUNTERTOP COOKING SURFACE 13" max (330) 6"min (152) TO COMBUSTIBLE MATERIALS 30" (762) OPENING WIDTH 3/4" (19) PLATFORM LOCATION OF GAS AND ELECTRICAL SUPPLY CUT-OUT WITHIN SHADED AREA THROUGH BOTTOM OF PLATFORM 8 1/2" (216) 3/4" (19) PLATFORM 7 1/2" (191) 16" (406) TOP VIEW OF PLATFORM 36" (914) 24" (610) 4" (102) E 16" (406) BACK WALL G ISLAND INSTALLATIONS: 12" (305) MINIMUM CLEARANCE FROM BACK OF RANGETOP TO COMBUSTIBLE REAR WALL ABOVE COUNTERTOP­ 0" (0) TO NON-COMBUSTIBLE MATERIALS Dimensions in parentheses are in millimeters unless otherwise specified. 7 W O L F S E A L E D B U R N E R R A N G E TO P 36" (914) S E A L E D B U R N E R R A N G E TO P 28 1/2" (724) OVERALL DEPTH OVERALL DIMENSIONS Overall Width Overall Height (to cooking surface) Overall Depth Opening Width 35 7/8" (911) COOKING SURFACE 9 1/4" (235) 27 1/2" (699) WITH 20" RISER (445) (318) WITH 10" WITH 5" RISER RISER 12 1/2" 17 1/2" 8 1/2" (216) 28 1/2" (724) 36" (914) 35 7/8" (911) OVERALL WIDTH 8 1/2" (216) OVERALL HEIGHT 7 1/2" (191) 24 1/4" (616) Dimensions may vary to ± 1/8" (3). I N S TA L L A T I O N S P E C I F I C A T I O N S IMPORTANT NOTE: For 36" (914) sealed burner rangetops, a minimum 5" (127) riser is required when installing Model SRT366 against a combustible surface. Remove and discard all packing materials, including cardboard and tape on the outside of the rangetop. Be sure to remove the burner caps packaged in styrofoam below the burner grates. If your installation requires a riser, it must be attached to the rangetop before installation. Gas supply and electrical connections should be made before the rangetop is placed in its final position. EXPLOSION HAZARD -- Use a certified gas supply line and install a gas shut-off valve. The maximum gas supply pressure to the regulator should never exceed 14" (34. 9 mb) WC (water column); . 5 psi (3. 5 kPa). Failure to do so can result in explosion, fire or death. TYPES OF GAS There are two types of gas, natural and liquid propane (LP). Conversions are required in order for appliances designed for one gas to be operated with the other gas. Such conversions must be performed by a Wolf authorized service center. Make sure your Wolf sealed burner rangetop is correctly adjusted for the type of gas being used. The product rating plate has information on the type of gas that should be used. If this information does not agree with the type of gas available, contact your Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance. com. Wolf sealed burner rangetops using natural gas will operate up to an altitude of 8, 000' (2438 m) without any adjustment. Natural gas and LP gas installations from 8, 000' (2438 m) to 11, 000' (3353 m) need the high altitude conversion kit. Contact your Wolf dealer for details. 10 I N S TA L L AT I O N I N S T R U C T I O N S G A S S U P P LY R E Q U I R E M E N T S Before connecting the gas supply, make sure all valves are in a closed position. Do not connect the gas supply to an appliance that shows any sign of physical damage. If rigid pipe is used as a gas supply line, a combination of pipe fittings must be used to obtain an in-line connection to the rangetop. [. . . ] The 6' (1. 8 m) power supply cord provided with the rangetop is equipped with a 3-prong, grounded plug for protection against shock hazard. IMPORTANT NOTE: You must follow all National Electrical Code and gas regulations. In addition, be aware of local codes and ordinances when installing your services. Grounding Plug Grounding-Type Electrical Outlet Electrical ground Dimensions in parentheses are in millimeters unless otherwise specified. 13 W O L F S E A L E D B U R N E R R A N G E TO P S U R FAC E B U R N E R S R E M OV I N G T H E R A N G E T O P INITIAL LIGHTING The surface burners use electronic igniters in place of standing pilots. When the rangetop control knob is pushed in and turned to the HIGH position, the system creates a spark to light the burner. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO SRT INSTALL GUIDE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO SRT INSTALL GUIDE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.