User manual SUB-ZERO PROWALLHOOD INSTALL GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SUB-ZERO PROWALLHOOD INSTALL GUIDE. We hope that this SUB-ZERO PROWALLHOOD INSTALL GUIDE user guide will be useful to you.


SUB-ZERO PROWALLHOOD INSTALL GUIDE : Download the complete user guide (1454 Ko)

Manual abstract: user guide SUB-ZERO PROWALLHOOD INSTALL GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] P R O W A L L V E N T I L AT I O N H O O D S INSTALLATION INSTRUCTIONS C O N TA C T I N F O R M AT I O N Wolf Customer Service: 800-332-9513 Website: wolfappliance. com As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equipment. There are two types of potential hazards that may occur during installation. signals a situation where minor injury or product damage may occur if you do not follow instructions. states a hazard that may cause serious injury or death if precautions are not followed. Another footnote we would like to identify is IMPORTANT NOTE: This highlights information that is especially relevant to a problemfree installation. WOLF ® is a registered trademark of Wolf Appliance Company, Inc. W O L F P R O WA L L V E N T I L AT I O N H O O D S I N S TA L L AT I O N R E Q U I R E M E N T S IMPORTANT NOTE: This installation must be completed by a qualified installer or Wolf authorized service center technician. Installer: Please read the entire Installation Instructions prior to installation. [. . . ] Pro wall hoods come standard with a backdraft damper included in the transition assembly. In cold weather installations a backdraft damper is necessary to minimize the backflow of cold air into the room. Consult your local HVAC professional for specific requirements in your area. SOFFIT OR CABINET OR DUCT COVER TRANSITION 22 1/4"W x 9"D TO 10" ROUND 10"H (INCLUDING FLANGES) VERTICAL DISCHARGE 18" (457) HEIGHT OF HOOD WALL HOOD 27" (686) DEPTH OF HOOD 30" TO 36" (762­914) COUNTERTOP TO BOTTOM OF VENTILATION HOOD 36" (914) STANDARD FLOOR TO COUNTERTOP HEIGHT VERTICAL DISCHARGE ONLY FOR 27" (686) DEEP WALL HOODS. Ducting options for 27" (686) deep wall hoods To reduce the risk of fire and electric shock, install this ventilation hood only with a blower manufactured by Wolf. Blower model numbers are listed on page 20. Dimensions in parentheses are in millimeters unless otherwise specified. 13 W O L F P R O WA L L V E N T I L AT I O N H O O D S 27" (686) DEEP WA L L H O O D S S T E P 2 : WA L L P R E PA R AT I O N ACCESSORIES Optional accessories are available through your Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance. com. Framing must be tied together and to ceiling joists to provide enough structural strength to support the weight of the hood and internal blower, if applicable. The hood assembly is shipped with the rough-in plate/transition attached. Remove the filters by pushing each filter up at the angle it is placed in, and rotate down. Then take out the grease cups placed on the bottom edge of the hood coinciding with the bottom edge of the filters. Gloves should be worn to provide the proper grip when removing filters. Detach the rough-in plate/transition assembly from the hood by removing the screws on the top and back of the assembly. Separate the transition from the rough-in plate by removing the four shipping screws. Do not discard the screws, they will be needed to reinstall the transition to the rough-in plate. Reattach the transition to the rough-in plate using the four shipping screws removed previously. Attach the transition to existing ductwork with sheet metal screws and duct sealing tape. Construct the wood wall framing flush with the wall studs and centered in the location that the hood will be mounted. Use the rough-in plate shipped with hood to determine the location of the framing. After the wall surface is finished, secure the rough-in plate to the wall surface. If wall framing is not available, wall anchors must be used. S T E P 3 : H O O D P R E PA R AT I O N IMPORTANT NOTE: If a duct cover is to be used, follow instructions on page 21 before installing the wall hood. Refer to the illustration below for the location of mounting holes for the 27" (686) wall hood. 91/2" (241) 21 1/4" (540) 10" (254) 41/2" (114) * 8 1/2" (216) 20" (508) 8" (203) * 41/2" (114) * * 41/2" (114) 13/16" (21) Shipping Screws Rough-In Plate Transition * * 41/2" (114) * * *Dimension is 2" (51) Mounting holes for 27" (686) hoods Rough-in plate installation 14 I N S TA L L AT I O N I N S T R U C T I O N S 27" (686) DEEP WA L L H O O D S If you are installing WBLOWER-90INT or WBLOWER-120INT, refer to the internal blower information on page 17 and follow installation instructions provided with the blower. If you are installing an in-line or remote blower, drill a 7/8" (22) hole through the wood framing for the conduit. Refer to the in-line and remote blower information on pages 18­19 and follow installation instructions provided with the blower. IMPORTANT NOTE: Do not run wiring for the remote blower through the ductwork. S T E P 4 : I N S TA L L R O U G H - I N P L AT E Use the rough-in plate assembly to determine the location of wall framing. Install the #10 x 1" (25) screws (included with the hood) through the rough-in plate into the wall framing. IMPORTANT NOTE: If additional support is required for the hood, drill supplementary mounting holes in the rough-in plate and use these holes to attach the hood assembly to the wall framing. S T E P 5 : I N S TA L L T H E H O O D IMPORTANT NOTE: If a backsplash is to be used, it should be installed before the wall hood is mounted. [. . . ] Position the top edge of the filter as shown in the illustration below. While pressing up against the spring, rotate the bottom edge of the filter into position next to the grease cup. Gloves should be worn to provide proper grip. ACCESSORIES Optional accessories are available through your Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance. com. IMPORTANT NOTE: If a duct cover is to be used, follow these instructions before installing the wall hood. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO PROWALLHOOD INSTALL GUIDE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO PROWALLHOOD INSTALL GUIDE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.