User manual SUB-ZERO PROLINER INSTALL GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SUB-ZERO PROLINER INSTALL GUIDE. We hope that this SUB-ZERO PROLINER INSTALL GUIDE user guide will be useful to you.


SUB-ZERO PROLINER INSTALL GUIDE : Download the complete user guide (931 Ko)

Manual abstract: user guide SUB-ZERO PROLINER INSTALL GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] Record the model and serial numbers before installing the Pro ventilation hood liner. Both numbers are listed on the rating plate, located on the left wall of the hood liner shell. Model Number Serial Number L I S T O F M AT E R I A L S The following is a list of materials shipped with the Wolf Pro ventilation hood liner. Pro Hood Liner Stainless steel hood liner Transition with backdraft damper (attached inside hood liner--needs to be removed) (2) Control knobs Filters (installed in hood liner) Grease cups (installed in hood liner-- Model L282212I only) (10) #10 x 2" (51) self-tapping hex head screws (10) 10-24 washer nuts Installation package (taped to filters) Installation Instructions Use & Care Information and product registration card Dimensions in parentheses are in millimeters unless otherwise specified. 3 W O L F P R O V E N T I L AT I O N H O O D L I N E R S I N S TA L L AT I O N C O N S I D E R A T I O N S IMPORTANT NOTE: Wolf Pro ventilation hood liners are recommended for use with all Wolf cooking appliances and are available to accommodate 30" (762), 36" (914), 42" (1067), 48" (1219), 54" (1372) and 60" (1524) wide hoods. ACCESSORIES Optional accessories are available through your Wolf dealer. [. . . ] Then take out the grease cups placed on the bottom edge of the hood liner coinciding with the bottom edge of the filters (Model L282212I only). Gloves should be worn to provide the proper grip when removing filters. Detach the rough-in plate/transition assembly from the hood liner by removing the screws on the top and back of the assembly. Separate the transition from the rough-in plate by removing the four shipping screws. Do not discard the screws, they will be needed to reinstall the transition to the rough-in plate. Construct the wood wall framing flush with the wall studs and centered in the location that the hood liner will be mounted. Use the rough-in plate shipped with hood liner to determine the location of the framing. After the wall surface is finished, secure the rough-in plate assembly to the wall. In addition, be aware of local codes and ordinances when installing your service. This ventilation hood liner must be properly grounded and should be installed by a qualified electrician in accordance with all applicable national and local electrical codes. Run a 120 V AC, 15 amp circuit (minimum) power cable from the service panel to the electrical box in the rough-in plate. Remove the knockout and install the conduit connector on the rough-in plate hole. Insert the conduit through the hole on top of the rough-in plate to the electrical box. Connect black wire to power supply black wire, white wire to power supply white wire and green wire to green wire or bare wire. Place all wiring connections inside the electrical box and reinstall on the rough-in plate. Make sure that the wires are secure and that no wires are pinched between the cover and box. Refer to the wiring diagram packaged with the hood liner for more information. Before servicing or cleaning, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 2 1/2" (64) 2" (51) 2 1/2" (64) Pro hood liner wiring location 10 I N S TA L L AT I O N I N S T R U C T I O N S INTERNAL B L OW E R IMPORTANT NOTE: Refer to the installation instructions provided with the internal blower for additional mounting and wiring instructions. IMPORTANT NOTE: Use wire connectors or wire nuts approved by UL or C/UL. IMPORTANT NOTE: Wolf recommends installing the internal blower to the rough-in plate assembly prior to installing the hood liner to the wall framing. L B L O W E R - 1 2 0 I N T I N S TA L L AT I O N Slide the blower mounting tab into the hood liner rough-in plate mounting slot. Make sure the blower tab and mounting slot are aligned properly front to back. Secure the blower with the weld stud at the back of the blower and hood liner rough-in plate with the nut (included with the blower). Verify that the blower discharge aligns with the rough-in plate discharge cut-out of the hood liner. Once the blower is attached to the hood liner rough-in plate, install the rough-in plate to the wall. Secure the power cord(s) without damaging or pinching while installing the hood liner shell. [. . . ] Check electrical connections to ensure that the installation has been completed correctly. Refer to the Troubleshooting Guide in the Wolf Pro Ventilation Hoods Use & Care Information. If the ventilation hood liner still does not work, contact a Wolf authorized service center. Wolf is not responsible for service required to correct a faulty installation. Maintain the quality built into your Pro ventilation hood liner by calling a Wolf authorized service center. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO PROLINER INSTALL GUIDE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO PROLINER INSTALL GUIDE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.