User manual SUB-ZERO OUTDOOR GAS GRILLS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SUB-ZERO OUTDOOR GAS GRILLS. We hope that this SUB-ZERO OUTDOOR GAS GRILLS user guide will be useful to you.


SUB-ZERO OUTDOOR GAS GRILLS : Download the complete user guide (198 Ko)

You may also download the following manuals related to this product:

   SUB-ZERO OUTDOOR GAS GRILLS DATASHEET (538 ko)

Manual abstract: user guide SUB-ZERO OUTDOOR GAS GRILLS

Detailed instructions for use are in the User's Guide.

[. . . ] The correct voltage, frequency and amperage must be supplied to the appliance from a dedicated, grounded circuit which is protected by a properly sized circuit breaker or time delay fuse. The proper voltage, frequency, and amperage ratings are listed on the product rating plate. Record the model and serial numbers before installing the outdoor grill. Both numbers are listed on the product rating plate, located behind the drip tray, below the logo. [. . . ] It should be plugged directly into a properly grounded 3-prong outlet. DO NOT use an extension cord or two-prong adapter. Outdoor Grill Installation 11 wolfappliance. com Gas Supply Requirements Connect the grill to the gas supply line. The gas supply line must be of adequate size to properly service all gas appliances. commercial type flex hose from the gas supply line to the grill connection. The units will operate on 1/2" (13) pipe to a maximum run of 30' (9 m). pipe. IMPORTANT NOTE: For complete gas shutdown, an external gas shut-off valve must be located near the appliance in an accessible location. Any LP gas cylinder used with this appliance must be constructed and marked in accordance with the specifications for LP gas cylinders of the U. S. Department of Transportation (D. O. T. ) or the National Standards of Canada CAN/CSA-B339, Cylinders, Spheres and Tubes for the Transportation of Dangerous Goods, and Commission, as applicable. Provided with a listed overfilling prevention device and a cylinder connection device compatible with the connection for outdoor cooking appliances. The LP gas cylinder must be provided with a shut-off valve terminating in the cylinder valve outlet. Do not use a cylinder that is dented, rusted or has a damaged valve. IMPORTANT NOTE: Do not operate the gas grill indoors or in any enclosed area. If the gas grill is not in use, the gas must be turned off at the LP gas cylinder. If the grill is to be stored indoors, disconnect the cylinder and leave it outdoors. Outdoor Grill Installation 13 wolfappliance. com LP Gas Installations PORTABLE LP CONNECTION LP GAS CONNECTION One of the many features of the Wolf grill cart is the pull-out shelf for easy access to the LP gas cylinder. 1) To install the LP gas cylinder, pull out the shelf and place the cylinder on it. 2) Check to ensure that the gas valve on top of the cylinder is closed. 3) Connect the LP gas regulator to the cylinder and hand-tighten only. Check for leaks according to the gas leak testing procedure on page 12. 4) Tighten the thumb screw to secure the cylinder to the shelf. Install the pressure regulator and hose assembly supplied with the grill as shown in the illustrations below. Connect the 3/8" flare end of the hose to the grill coupling using a 3/4" open wrench. Connect the regulator to the LP cylinder hand-tighten, do not use a wrench. The LP pressure regulator and hose supplied with the grill must be used without alteration. Do not place more than one LP gas cylinder in an enclosure at one time. Always check for gas leaks after changing the LP gas cylinder. REGULATOR COUPLING NUT GRILL COUPLING TO GRILL REGULATOR HOSE ASSEMBLY LP GAS CYLINDER VENT VENT VENT LP GAS CYLINDER LP gas connection. LP gas regulator. Grill cart pull-out shelf. Outdoor Grill Installation 14 Gas Leak Testing IMPORTANT NOTE: Never use the outdoor grill without first testing the gas line connections for gas leaks. GAS LEAK TESTING PROCEDURE Perform a gas leak test each time the LP gas cylinder is connected to the regulator and any time part of the gas system is disconnected or replaced. Perform a leak test at least once each year whether the LP gas cylinder has been disconnected or not. IMPORTANT NOTE: To prevent fire or explosion hazard, do not smoke or permit sources of ignition in the area while performing a leak test. [. . . ] The correct pressure regulator is connected for natural or LP gas and set for 4" (10 mb) WC for natural gas or 10" (25 mb) WC for LP gas. The LP gas cylinder is in an upright position and the hose is not kinked. The homeowner has been informed of the gas supply shut-off valve location. Be sure to disconnect the electrical and gas supply before servicing. Service Information 17 wolfappliance. com Service Information If service is necessary, maintain the quality built into your outdoor grill by calling a Wolf authorized service center. To obtain the name and number of a Wolf authorized service center, check the contact & support section of our website, wolfappliance. com or call Wolf customer service at 800-332-9513. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO OUTDOOR GAS GRILLS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO OUTDOOR GAS GRILLS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.