User manual SUB-ZERO INDUCTION INSTALL GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SUB-ZERO INDUCTION INSTALL GUIDE. We hope that this SUB-ZERO INDUCTION INSTALL GUIDE user guide will be useful to you.


SUB-ZERO INDUCTION INSTALL GUIDE : Download the complete user guide (203 Ko)

Manual abstract: user guide SUB-ZERO INDUCTION INSTALL GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] Model Number CT15I/S Serial Number Proper installation is your responsibility. You must also assure that electrical installation is adequate and in compliance with all local codes and ordinances. Installations and repairs must be performed by a qualified or licensed contractor or electrician qualified or licensed by the state, province, or region where this appliance is being installed. It is the responsibility of the installer to comply with the installation clearances specified on the model/ serial rating plate. [. . . ] IMPORTANT NOTE: A minimum height clearance of 6" (152) is required. If a shelf is installed below the unit, a 1" (25) gap at the rear of the cabinet shelf is necessary to allow for proper ventilation. Failure to do so could result in decreased performance or product damage. MODEL CT15I/S DIMENSIONS Overall Width Overall Height Overall Depth Minimum Cabinet Depth Minimum Height Clearance Cut-Out Width* Cut-Out Depth 15" (381) 2 1/2" (64) 21" (533) 22 3/4" (578) 6" (152) 13 3/8" (340) 19 1/4" (489) *If the induction cooktop is to be used with any combination of additional cooktops or modules with a filler strip, the cut-out width increases to 14" (356). 21" (533) OVERALL DEPTH 15" (381) OVERALL WIDTH 19 1/4" (489) COOKTOP CUT-OUT DEPTH 24" OR 30"* (610 or 762) TO COOKING SURFACE 18" (457) 33" (838) RECOMMENDED CABINET WIDTH 13 3/8" (340) CUT-OUT WIDTH 18" (457) 2 1/2" (64) 2 1/2"min (64) 2"** (51) 2"** (51) 6" Overall Dimensions 36" (914) STANDARD FLOOR TO COUNTER HEIGHT E (152) 15" (381) 15" (381) NOTE: Application shown allows for installation of two 15" (381) modules side-by-side. *Minimum 24" (610) from protected cabinet or 30" (762) from unprotected cabinet to cooking surface. **Minimum clearance from side edge of cooktop cut-out to combustible surface up to 18" (457) above cooking surface. Installation Specifications and Countertop Cut-Out Dimensions 13 3/8" (340) COOKTOP CUT-OUT WIDTH 19 1/4" (489) 2 1/2"min (64) COOKTOP CUT-OUT DEPTH Dimensions in parentheses are in millimeters unless otherwise specified. FRONT OF COUNTERTOP 5 W O L F I N D U C T I O N C O O K TO P I N S TA L L AT I O N S P E C I F I C A T I O N S C O U N T E R T O P C U T- O U T The induction cooktop is designed to fit a standard 24" (610) deep base cabinet with 25" (635) deep countertop. Before making the cooktop cut-out, verify that the cooktop will clear the side walls of the base cabinet below. There should be at least 5 1/2" (140) clearance between the top countertop surface and any combustible surface directly below the unit. IMPORTANT NOTE: When multiple cooktops and/or modules are installed side by side, refer to the illustration below for countertop cut-out dimensions. IMPORTANT NOTE: Plastic or other utensils with low melting temperatures should not be located in drawers directly below unit. M U LT I P L E C O O K T O P I N S T A L L AT I O N IMPORTANT NOTE: If the induction cooktop is to be used with any combination of additional cooktop units or modules with a filler strip, the cut-out width is calculated by adding the corresponding units' cut-out dimensions plus 1 1/4" (32) for each additional unit. If multiple modules are to be installed, the cutout width of the induction cooktop should be increased from 13 3/8" (340) to 14" (356). IMPORTANT NOTE: When multiple units are installed side by side, each unit must have its own separate recommended electrical circuit. IMPORTANT NOTE: When two or more modules are installed together, an integrated module filler strip (IFILLER/S) is required. If a downdraft ventilation system is also installed, an integrated module support for downdraft ventilation (ISUPPORT) is required. Contact your Wolf dealer for information on these accessory components. 593/4" (1518) FOUR MODULES WIDTH OR 591/2" (1511) 30" COOKTOP AND TWO MODULES OR 501/4" (1276) 36" COOKTOP AND ONE MODULE 441/2" (1130) THREE MODULES WIDTH OR 441/4" (1124) 30" COOKTOP AND ONE MODULE 291/4" (743) TWO MODULES WIDTH 14" 21/2"min (64) (356) CUT-OUT WIDTH 191/4" (489) CUT-OUT DEPTH FRONT OF COUNTERTOP Countertop cut-out dimensions for installation of multiple cooktops 6 I N S TA L L AT I O N I N S T R U C T I O N S V E N T I L AT I O N O P T I O N S IMPORTANT NOTE: It is recommended that you operate the Wolf induction cooktop with either a Wolf cooktop hood, downdraft system or Pro ventilation hood. Cooktop Wall Hood ­ 30" (762) or 36" (914) widths in classic stainless steel. Cooktop Island Hood ­ 42" (1067) width in classic stainless steel. Downdraft Ventilation System ­ 30" (762) or 36" (914) widths, with top cover and control panel in classic, platinum and carbon stainless steel finishes (adequate countertop depth is required). Pro Wall Hood ­ 22" (559), 24" (610) or 27" (686) depths and 30" (762) to 66" (1676) widths in classic stainless steel. Pro Island Hood ­ 36" (914) to 66" (1676) widths in classic stainless steel. Pro Hood Liner ­ available in widths to accommodate 30" (762) to 60" (1524) hood shells. All hoods have welded seams, sealed halogen lighting and removable dishwasher safe stainless steel filters. [. . . ] Improper connection can result in a fire hazard! 8 Dimensions in parentheses are in millimeters unless otherwise specified. I N S TA L L AT I O N I N S T R U C T I O N S C O O K T O P I N S TA L L AT I O N B E F O R E O P E R AT I N G T H E C O O K T O P L O C AT I N G U N I T I N C O U N T E R T O P Attach the foam strip to the underside of the cooktop frame. Gently lower the unit into the cut-out area in the countertop and center. Wolf is not responsible for service required to correct a faulty installation. This product must be repaired only by a Wolf Factory Authorized Service Center technician. The cooktop must be disconnected from power prior to service. 10 Dimensions in parentheses are in millimeters unless otherwise specified. I N S TA L L AT I O N I N S T R U C T I O N S I F Y O U N E E D S E RV I C E Maintain the quality built into your induction cooktop by calling a Wolf Factory Authorized Service Center. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO INDUCTION INSTALL GUIDE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO INDUCTION INSTALL GUIDE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.