User manual SUB-ZERO GASCT INSTALL GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SUB-ZERO GASCT INSTALL GUIDE. We hope that this SUB-ZERO GASCT INSTALL GUIDE user guide will be useful to you.


SUB-ZERO GASCT INSTALL GUIDE : Download the complete user guide (260 Ko)

Manual abstract: user guide SUB-ZERO GASCT INSTALL GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] G AS C OOKTOPS INSTALLATION INSTRUCTIONS As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equipment. There are two types of potential hazards that may occur during installation. signals a situation where minor injury or product damage may occur if you do not follow instructions. states a hazard that may cause serious injury or death if precautions are not followed. Another footnote we would like to identify is IMPORTANT NOTE: This highlights information that is especially relevant to a problemfree installation. WOLF ® is a registered trademark of Wolf Appliance Company, Inc. W O L F G A S C O O K TO P S I N S TA L L AT I O N R E Q U I R E M E N T S IMPORTANT NOTE: This installation must be completed by a qualified installer, service agency or gas supplier. IMPORTANT NOTE: Save these Installation Instructions for the local inspector's use. [. . . ] When a 36" (914) built-in oven is installed below Model CT36G, it is recommended that the rough opening for the oven be 7 3/4" (197) from the floor to ease the use of the oven door. IMPORTANT NOTE: When multiple units are installed side by side, each unit must have its own separate recommended electrical circuit. When multiple gas units are installed next to one another, they can receive their gas supply from a common line. However, each unit MUST have its own regulator installed between the mainline and the gas cooktop. When two or more modules are installed together, an integrated module filler strip (IFILLER/S) is recommended. If a downdraft ventilation system is also installed, an integrated module support for downdraft ventilation (ISUPPORT) is also required (Model DD30 only). Contact your Wolf dealer for information on these accessory components. OPTIONAL I N S TA L L AT I O N S Dimensions will vary according to the specific installation. 593/4" (1518) FOUR MODULES WIDTH OR 591/2" (1511) 30" COOKTOP AND TWO MODULES OR 501/4" (1276) 36" COOKTOP AND ONE MODULE 441/2" (1130) THREE MODULES WIDTH OR 441/4" (1124) 30" COOKTOP AND ONE MODULE 291/4" (743) TWO MODULES WIDTH 14" 21/2"min (64) (356) CUT-OUT WIDTH 191/4" (489) CUT-OUT DEPTH FRONT OF COUNTERTOP Countertop cut-out dimensions for installation of multiple cooktops Dimensions in parentheses are in millimeters unless otherwise specified. 9 W O L F G A S C O O K TO P S G A S S U P P LY R E Q U I R E M E N T S EXPLOSION HAZARD -- Use a new CSA approved gas supply line and install a gas shut-off valve. I M P O R TA N T N OT E This installation must conform with local codes and ordinances. In the absence of local codes, installations must conform with the American National Standard, National Fuel Gas Code and National Electrical Code regulations. Securely tighten all gas connections. For LP gas, have a qualified technician make sure the gas pressure does not exceed 14" (34. 9 mb) WC (water column). Failure to do so can result in explosion, fire or death. If local codes permit, a new CSA designcertified, 4­5' (1. 2­1. 5 m) long, 1/2" or 3/4" ID, flexible metal appliance connector is recommended for connecting this cooktop to the gas supply line. You will need to determine the fittings required, depending on the size of your gas supply line, flexible metal connector and shutoff valve. If rigid pipe is used as a gas supply line, a combination of pipe fittings must be used to obtain an in-line connection to the cooktop. All strains must be removed from the supply and gas lines so the cooktop will be level and in line. IMPORTANT NOTE: The supply line must be equipped with an approved external gas shut-off valve located near the cooktop in an accessible location. The inlet pressure to the regulator should be as follows for operation and checking the regulator setting: Natural Gas: Set pressure 5" (12. 5 mb) WC, supply pressure 7­14" (17. 5­34. 9 mb) max. LP Gas: Set pressure 10" (25 mb) WC, supply pressure 11­14" (27. 4­34. 9 mb) WC. IMPORTANT NOTE: The gas cooktop must be connected to a regulated gas supply. IMPORTANT NOTE: This installation must conform with local codes and ordinances. In the absence of local codes, installations must conform with American National Standard, National Fuel Gas Code ANSI Z223. 1 ­ latest edition or CANI ­ B149. 1 or 2. IMPORTANT NOTE: The natural gas cooktop is rated for elevations up to 8, 000' (2438 m) without adjustment. Install a high altitude kit for elevations from 8, 000' (2438 m) to 10, 000' (3084 m). It is design certified by the Canadian Standards Association (CSA) for natural or LP gases. The rating plate, located on the underside of the burner box, has information on the type of gas that should be used. [. . . ] You will need to determine the fittings required, depending on the size of your gas supply line, flexible metal connector and shutoff valve. If a flexible metal connector is used, be sure the tubing is not kinked. GAS LEAK TESTING Use a brush and liquid detergent to test all gas connections for leaks. If a leak appears, shut off gas valve controls and adjust connections. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO GASCT INSTALL GUIDE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO GASCT INSTALL GUIDE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.