User manual SUB-ZERO DUALFUEL INSTALL GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SUB-ZERO DUALFUEL INSTALL GUIDE. We hope that this SUB-ZERO DUALFUEL INSTALL GUIDE user guide will be useful to you.


SUB-ZERO DUALFUEL INSTALL GUIDE : Download the complete user guide (289 Ko)

Manual abstract: user guide SUB-ZERO DUALFUEL INSTALL GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] D UAL F UEL R ANGES INSTALLATION INSTRUCTIONS As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equipment. There are two types of potential hazards that may occur during installation. signals a situation where minor injury or product damage may occur if you do not follow instructions. states a hazard that may cause serious injury or death if precautions are not followed. Another footnote we would like to identify is IMPORTANT NOTE: This highlights information that is especially relevant to a problemfree installation. WOLF ® is a registered trademark of Wolf Appliance Company, LLC W O L F D UA L F U E L R A N G E S I N S TA L L AT I O N R E Q U I R E M E N T S IMPORTANT NOTE: This installation must be completed by a qualified installer, service agency or gas supplier. IMPORTANT NOTE: Save these Installation Instructions for the local inspector's use. [. . . ] If removal of the oven door(s) is necessary, a hinge pin, supplied with the range, will need to be inserted in the appropriate hinge arm. For each oven door, only one hinge arm is spring loaded, requiring use of the hinge pin for removal of the oven door. For 30" (762) and 36" (914) ranges, the hinge pin will be inserted through the hole in the right hinge arm (facing the unit). On 48" (1219) and 60" (1524) ranges, the spring hinges are located on the outer edges of the unit. On these units, the left oven door will have the spring hinge on the left side and the right oven door will have the spring hinge on the right side. Refer to the illustrations below for the location of the spring hinge(s) for your model. Do not lift or carry the oven door by the door handle. Hinge Retainer Plate Hinge Pin Upper Mounting Screw Place Hinge Pin on Spring Hinge Side of Door Place Hinge Pins on Spring Hinge Side of Door Kickplate Spring hinge location for 30" (762) and 36" (914) ranges. 12 Spring hinge locations for 48" (1219) and 60" (1524) ranges. Oven door removal I N S TA L L AT I O N I N S T R U C T I O N S G A S S U P P LY R E Q U I R E M E N T S Provide a gas supply line of 3/4" rigid pipe to the range location. A smaller size pipe on long runs may result in insufficient gas supply. LP gas suppliers usually determine the size and materials used on the system. If local codes permit, a new CSA design certified, 3' (. 9 m) long, 1/2" or 3/4" ID flexible metal appliance connector is recommended for connecting this range to the gas supply line. The pipe coming out the bottom of the unit has 1/2" male threads. You will need to determine the fittings required, depending on the size of your gas supply line, flexible metal connector and shut-off valve. If rigid pipe is used as a gas supply line, a combination of pipe fittings must be used to obtain an in-line connection to the range. All strains must be removed from the supply and gas lines so the range will be level and in line. IMPORTANT NOTE: The supply line must be equipped with an approved external gas shut-off valve located near the range in an accessible location. Refer to the illustration below. EXPLOSION HAZARD -- Use a new CSA approved gas supply line and install a gas shut-off valve. For LP gas, have a qualified technician make sure the gas pressure does not exceed 14" (34. 9 mb) WC (water column). Failure to do so can result in explosion, fire or death. I M P O R TA N T N OT E This installation must conform with local codes and ordinances. In the absence of local codes, installations must conform with the American National Standard, National Fuel Gas Code. IMPORTANT NOTE: The dual fuel range must be connected to a regulated gas supply. IMPORTANT NOTE: This installation must conform with local codes and ordinances. In the absence of local codes, installations must conform with American National Standard, National Fuel Gas Code ANSI Z223. 1 ­ latest edition or CANI ­ B149. 1 or 2. It is design certified by the Canadian Standards Association (CSA) for natural or LP gases. [. . . ] Check that the power supply cord is plugged in and that the circuit breaker or house fuse has not blown. Check operation again; if the burners do not light properly at this point, contact a Wolf authorized service center. IMPORTANT NOTE: Initial lighting of the surface burners may take slightly longer, as air in the system must be purged before gas can be supplied to the burner. Do not lift or carry the oven door by the door handle. Dimensions in parentheses are in millimeters unless otherwise specified. 17 W O L F D UA L F U E L R A N G E S V E R I F Y R A N G E O P E R AT I O N R E M OV I N G T H E R A N G E IMPORTANT NOTE: Prior to operating the range, be sure to read the entire Wolf Dual Fuel Ranges Use & Care Information included with the range for important safety, service and warranty information. Install the oven rack guides onto the shoulder screws located on the interior side walls of the oven. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO DUALFUEL INSTALL GUIDE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO DUALFUEL INSTALL GUIDE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.