User manual SUB-ZERO DESIGN BROCHURE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SUB-ZERO DESIGN. We hope that this SUB-ZERO DESIGN user guide will be useful to you.


SUB-ZERO DESIGN BROCHURE: Download the complete user guide (4849 Ko)

Manual abstract: user guide SUB-ZERO DESIGNBROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] 92 Features and specifications are subject to change at any time without notice. Visit subzero. com/specs for the most up-to-date information. IMPORTANT NOTE: Throughout this guide, dimensions in parentheses are millimeters unless otherwise specified. MODELS BI-36RG AND BI-36F Built-In Refrigeration 3 subzero. com/specs Built-In Refrigeration. For the built-in line, Sub-Zero designers and engineers took a fresh look at everything, inside and out. Exterior refinements include redesigned grilles and lower-profile hinges. [. . . ] A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation. IMPORTANT NOTE: It is critical that the electrical outlet be located within the shaded area shown so it does not interfere with installation of the anti-tip bracket. It must be flush with the back wall and positioned with the grounding prong to the right of the thinner blades. Electrical Requirements Power Supply Circuit Breaker Receptacle 115 V AC, 60 Hz 15 amp 3-prong grounding-type LEFT SIDE OF OPENING LEFT SIDE OF OPENING 21/2" (64) 13" (330) 4 1/2" (114) 21/2" (64) 17 1/2" (445) 4 1/2" (114) 1/4" (6) FLOOR FRONT VIEW 1/4" (6) FLOOR FRONT VIEW 27" (686) models. 36" (914) models. Integrated Refrigeration 57 subzero. com/specs Plumbing Requirements For integrated models with an automatic ice maker, the water supply line should be located through the floor or back wall, within the shaded area shown in the illustrations. The water supply line should be connected to the house supply with an easily accessible shut-off valve between the supply and the unit. A saddle valve kit (4200880) is available through your authorized Sub-Zero dealer. IMPORTANT NOTE: It is critical that the water line be located within the shaded area shown so it does not interfere with installation of the anti-tip bracket. 13 1/2" (343) BACK WALL 6" (152) 11/2" (38) 21/2" (64) 13 1/2" (343) 21/2" (64) 3" (76) 3/4" FLOOR FRONT VIEW (19) TOP VIEW An in-line filter is required when water conditions have a high sediment content. The ice maker operates on constant water pressure between 20 psi (1. 4 bar) and 100 psi (6. 9 bar). IMPORTANT NOTE: In some cases, a reverse osmosis water filter system may not be able to maintain the minimum pressure consistently. 36" (914) models. Plumbing Requirements Water Supply Line Water Pressure Excess Water Line for Connection 1/4" OD copper line 20­100 psi (1. 4­6. 9 bar) 27" (686) 9" (229) BACK WALL 6" (152) 11/2" (38) 21/2" (64) 9" (229) 21/2" (64) 3" (76) 3/4" FLOOR FRONT VIEW (19) TOP VIEW 27" (686) models. Integrated Refrigeration 58 Cabinetry Applications FRAMELESS CABINETRY 26 3/4" (679) PANEL WIDTH A A 26 3/4" (679) PANEL WIDTH A 35 3/4" (908) PANEL WIDTH 76 7/8" (1953) 45 3/8" (1153) 45 3/8" (1153) 807/8" (2054) 79 7/8" (2029) 79 7/8" (2029) A A 13 9/16" (345) 13 9/16" (345) A A 34 1/2" (876) 16 11/16" (424) 16 11/16" (424) 4" (102) 27" (686) FINISHED OPENING 4" (102) 27" (686) FINISHED OPENING ALL REVEALS (A) ARE 1/8" (3). 4" (102) 36" (914) FINISHED OPENING COLUMN MODELS 27" (686) MODELS TALL AND DRAWER MODELS 36" (914) MODELS TALL MODELS Typical Panel Dimensions COLUMN MODELS W H Panel dimensions are based on a 1/8" (3) reveal. A reveal of up to 1/4" (6) is possible with adjustments to panel dimensions. Door 27" (686) MODELS 26 3/4" (679) W 76 7/8" (1953) H Door Top Drawer Bottom Drawer 36" (914) MODELS 26 3/4" (679) 26 3/4" (679) 26 3/4" (679) W 45 3/8" (1153) 13 9/16" (345) 16 11/16" (424) H Door Top Drawer Bottom Drawer 35 3/4" (908) 35 3/4" (908) 35 3/4" (908) 45 3/8" (1153) 13 9/16" (345) 16 11/16" (424) Integrated Refrigeration 59 subzero. com/specs Cabinetry Applications DOOR PANEL HEIGHT TOE KICK CLEARANCE The height of the door panel can extend beyond the typical panel height, provided you do not exceed the panel weight limit. The illustration below shows how the panel may be extended and what you need to consider to finish the area behind the door panel. IMPORTANT NOTE: The decorative valance used to finish the area behind the door panel must stay behind the front plane of the finished molding. The toe kick clearance can vary with the height of the panel. You must keep a minimum space of 4" (102) clear below the bottom edge of the panel for proper venting. In addition, any decorative base molding must be removable to clean the condenser and for service. 25" (635) TO WALL 11/2" (38) INTEGRATED UNIT (SIDE VIEW) 1/8"(3) DECORATIVE VALANCE CANNOT EXTEND BEYOND THE FRONT OF THE MOLDING OVERALL HEIGHT DOOR PANEL DECORATIVE VALANCE HEIGHT OF PANEL KICKPLATE/GRILLE CAN BE ADJUSTED FORWARD KICKPLATE/GRILLE 1/8"(3) REMOVABLE MOLDING HINGE BASE MOLDING MUST BE REMOVABLE MINIMUM HEIGHT 4" (102) TO 9" (229) TYPICAL HEIGHT OF DOOR PANEL FROM FLOOR INTEGRATED UNIT (SIDE VIEW) 25" (635) TO WALL 2 5/8" (67) TO 4" (102) UPPER VALANCE COLUMN AND TALL MODELS KICKPLATE / GRILLE AREA ALL INTEGRATED MODELS Integrated Refrigeration 60 Cabinetry Applications Integrated refrigeration is compatible with virtually any style and look of cabinetry. Because of the precise application and the look you may want to achieve, keep the following considerations in mind: The thickness of the front panels can vary. A minimum (16) thick panel is required, but the thickness can be increased provided the panel weight limit is not exceeded. 5/8" IMPORTANT NOTE: The inside edges of the rough opening as well as the sides and a portion of the backside of the decorative panels will need to be finished, as they will be exposed when the doors are open. D-style handles are recommended. For the cabinet door, handles must be located near the edge of the panel opposite the hinge, centered top to bottom. Illustrations on the following pages show typical applications of frameless and framed cabinetry. Also refer to the full-scale illustration at the end of this section for specifics on door openings. IMPORTANT NOTE: The depth of each integrated model is 24" (610) from the front of the unit to its back. You must allow for the thickness of the panel you are applying when planning for the finished rough opening depth if you want the front panel to be flush with surrounding cabinetry. You may have to move the unit back into drywall or bring the cabinets forward to achieve a flush fit. Panel Requirements COLUMN MODELS MAX WEIGHT Reveals between panels can vary. A reveal of 1/8" (3) is typical, but reveals can be increased to up to 1/4" (6). Door Panel TALL AND DRAWER MODELS 65 lbs (29 kg) MAX WEIGHT As reveals between cabinetry and the unit decrease, the potential exists for severe finger pinching while the door is closing. 27" (686) Door Panel 27" (686) Drawer Panel 36" (914) Door Panel 36" (914) Drawer Panel PANEL THICKNESS 40 lbs (18 kg) 12 lbs (5 kg) 53 lbs (24 kg) 16 lbs (7 kg) MINIMUM 5/8" All Panels (16) When 3/4" (19) or thicker panels are used with a reveal of less than 1/4" (6), door panels may cause damage to the unit when the door is opened to the maximum 105°. Use the built-in 90° door stop. Integrated Refrigeration 61 subzero. com/specs Cabinetry Applications The illustrations below show typical applications of framed and frameless cabinetry. Refer to the full-scale templates at the end of this section for specifics on door openings. Dual Installations Two integrated units may be placed side by side in a dual installation. Depending on the models specified, opening widths will be 54" (1372), 63" (1600) or 72" (1829). A reveal of up to 1/4" (6) is possible with adjustments to panel dimensions. CABINET INTEGRATED UNIT CABINET INTEGRATED UNIT Typical Panel Dimensions COLUMN MODELS W H Door 27" (686) MODELS DOOR 1/8" (3) REVEAL PANEL DOOR 1/8" (3) REVEAL PANEL 26 13/16" (681) W 76 7/8" (1953) H FINISHED OPENING FINISHED OPENING Door Top Drawer Bottom Drawer 36" (914) MODELS 26 13/16" (681) 26 13/16" (681) 26 13/16" (681) W 45 3/8" (1153) 13 9/16" (345) 16 11/16" (424) H Framed--full overlay. Framed--standard overlay. Door Top Drawer Bottom Drawer 35 13/16" (910) 35 13/16" (910) 35 13/16" (910) 45 3/8" (1153) 13 9/16" (345) 16 11/16" (424) CABINET UNIT CABINET INTEGRATED UNIT A dual installation kit is required for installations with 2" (51) or less space between the units. Dual installation kits are available through your authorized Sub-Zero dealer. IMPORTANT NOTE: If a 27" (686) unit is installed next to a 36" (914) tall unit, the decorative front panels will align, however, the face frames will not. [. . . ] Service will be provided in the home during the normal business hours. This warranty applies only to products installed for normal residential use. Details regarding a non-residential warranty are available upon request. The warranty applies only to products installed in any one of the fifty states of the United States, the District of Columbia or the ten provinces of Canada. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO DESIGN




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO DESIGN will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.