User manual SUB-ZERO DESIGN BROCHURE
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SUB-ZERO DESIGN. We hope that this SUB-ZERO DESIGN user guide will be useful to you.
Manual abstract: user guide SUB-ZERO DESIGNBROCHURE
Detailed instructions for use are in the User's Guide.
[. . . ] 92
Features and specifications are subject to change at any time without notice. Visit subzero. com/specs for the most up-to-date information.
IMPORTANT NOTE: Throughout this guide, dimensions in parentheses are millimeters unless otherwise specified.
MODELS BI-36RG AND BI-36F
Built-In Refrigeration
3 subzero. com/specs
Built-In Refrigeration. For the built-in line, Sub-Zero designers and engineers took a fresh look at everything, inside
and out. Exterior refinements include redesigned grilles and lower-profile hinges. [. . . ] A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
IMPORTANT NOTE: It is critical that the electrical outlet be located within the shaded area shown so it does not interfere with installation of the anti-tip bracket. It must be flush with the back wall and positioned with the grounding prong to the right of the thinner blades.
Electrical Requirements
Power Supply Circuit Breaker Receptacle 115 V AC, 60 Hz 15 amp 3-prong grounding-type
LEFT SIDE OF OPENING
LEFT SIDE OF OPENING
21/2" (64)
13" (330) 4 1/2"
(114)
21/2" (64)
17 1/2" (445) 4 1/2"
(114)
1/4" (6)
FLOOR FRONT VIEW
1/4" (6)
FLOOR FRONT VIEW
27" (686) models.
36" (914) models.
Integrated Refrigeration
57 subzero. com/specs
Plumbing Requirements
For integrated models with an automatic ice maker, the water supply line should be located through the floor or back wall, within the shaded area shown in the illustrations. The water supply line should be connected to the house supply with an easily accessible shut-off valve between the supply and the unit. A saddle valve kit (4200880) is available through your authorized Sub-Zero dealer.
IMPORTANT NOTE: It is critical that the water line be located within the shaded area shown so it does not interfere with installation of the anti-tip bracket.
13 1/2"
(343)
BACK WALL
6"
(152)
11/2"
(38)
21/2" (64) 13 1/2"
(343)
21/2"
(64)
3" (76)
3/4" FLOOR FRONT VIEW (19)
TOP VIEW
An in-line filter is required when water conditions have a high sediment content. The ice maker operates on constant water pressure between 20 psi (1. 4 bar) and 100 psi (6. 9 bar).
IMPORTANT NOTE: In some cases, a reverse osmosis water filter system may not be able to maintain the minimum pressure consistently.
36" (914) models.
Plumbing Requirements
Water Supply Line Water Pressure Excess Water Line for Connection
1/4"
OD copper line
20100 psi (1. 46. 9 bar) 27" (686)
9"
(229)
BACK WALL
6"
(152)
11/2"
(38)
21/2" (64) 9"
(229)
21/2"
(64)
3" (76)
3/4" FLOOR FRONT VIEW (19)
TOP VIEW
27" (686) models.
Integrated Refrigeration
58
Cabinetry Applications
FRAMELESS CABINETRY
26 3/4" (679) PANEL WIDTH
A A
26 3/4" (679) PANEL WIDTH
A
35 3/4" (908) PANEL WIDTH
76 7/8"
(1953)
45 3/8"
(1153)
45 3/8"
(1153)
807/8"
(2054)
79 7/8"
(2029)
79 7/8"
(2029)
A
A
13 9/16"
(345)
13 9/16"
(345)
A
A
34 1/2"
(876)
16 11/16"
(424)
16 11/16"
(424)
4" (102) 27" (686) FINISHED OPENING
4" (102) 27" (686) FINISHED OPENING
ALL REVEALS (A) ARE 1/8" (3).
4" (102) 36" (914) FINISHED OPENING
COLUMN MODELS
27" (686) MODELS
TALL AND DRAWER MODELS
36" (914) MODELS
TALL MODELS
Typical Panel Dimensions
COLUMN MODELS W H
Panel dimensions are based on a 1/8" (3) reveal. A reveal of up to 1/4" (6) is possible with adjustments to panel dimensions.
Door
27" (686) MODELS
26 3/4" (679)
W
76 7/8" (1953)
H
Door Top Drawer Bottom Drawer
36" (914) MODELS
26 3/4" (679) 26 3/4" (679) 26 3/4" (679)
W
45 3/8" (1153) 13 9/16" (345) 16 11/16" (424)
H
Door Top Drawer Bottom Drawer
35 3/4" (908) 35 3/4" (908) 35 3/4" (908)
45 3/8" (1153) 13 9/16" (345) 16 11/16" (424)
Integrated Refrigeration
59 subzero. com/specs
Cabinetry Applications
DOOR PANEL HEIGHT TOE KICK CLEARANCE
The height of the door panel can extend beyond the typical panel height, provided you do not exceed the panel weight limit. The illustration below shows how the panel may be extended and what you need to consider to finish the area behind the door panel.
IMPORTANT NOTE: The decorative valance used to finish the area behind the door panel must stay behind the front plane of the finished molding.
The toe kick clearance can vary with the height of the panel. You must keep a minimum space of 4" (102) clear below the bottom edge of the panel for proper venting. In addition, any decorative base molding must be removable to clean the condenser and for service.
25" (635) TO WALL
11/2"
(38)
INTEGRATED UNIT (SIDE VIEW)
1/8"(3)
DECORATIVE VALANCE CANNOT EXTEND BEYOND THE FRONT OF THE MOLDING
OVERALL HEIGHT
DOOR PANEL
DECORATIVE VALANCE
HEIGHT OF PANEL
KICKPLATE/GRILLE CAN BE ADJUSTED FORWARD KICKPLATE/GRILLE
1/8"(3) REMOVABLE MOLDING HINGE
BASE MOLDING MUST BE REMOVABLE
MINIMUM HEIGHT
4" (102) TO 9" (229)
TYPICAL HEIGHT OF DOOR PANEL
FROM FLOOR INTEGRATED UNIT (SIDE VIEW)
25" (635) TO WALL
2 5/8" (67) TO 4" (102)
UPPER VALANCE
COLUMN AND TALL MODELS
KICKPLATE / GRILLE AREA
ALL INTEGRATED MODELS
Integrated Refrigeration
60
Cabinetry Applications
Integrated refrigeration is compatible with virtually any style and look of cabinetry. Because of the precise application and the look you may want to achieve, keep the following considerations in mind: The thickness of the front panels can vary. A minimum (16) thick panel is required, but the thickness can be increased provided the panel weight limit is not exceeded.
5/8"
IMPORTANT NOTE: The inside edges of the rough opening as well as the sides and a portion of the backside of the decorative panels will need to be finished, as they will be exposed when the doors are open.
D-style handles are recommended. For the cabinet door, handles must be located near the edge of the panel opposite the hinge, centered top to bottom. Illustrations on the following pages show typical applications of frameless and framed cabinetry. Also refer to the full-scale illustration at the end of this section for specifics on door openings.
IMPORTANT NOTE: The depth of each integrated model is 24" (610) from the front of the unit to its back. You must allow for the thickness of the panel you are applying when planning for the finished rough opening depth if you want the front panel to be flush with surrounding cabinetry. You may have to move the unit back into drywall or bring the cabinets forward to achieve a flush fit.
Panel Requirements
COLUMN MODELS MAX WEIGHT
Reveals between panels can vary. A reveal of 1/8" (3) is typical, but reveals can be increased to up to 1/4" (6).
Door Panel
TALL AND DRAWER MODELS
65 lbs (29 kg)
MAX WEIGHT
As reveals between cabinetry and the unit decrease, the potential exists for severe finger pinching while the door is closing.
27" (686) Door Panel 27" (686) Drawer Panel 36" (914) Door Panel 36" (914) Drawer Panel
PANEL THICKNESS
40 lbs (18 kg) 12 lbs (5 kg) 53 lbs (24 kg) 16 lbs (7 kg)
MINIMUM
5/8"
All Panels
(16)
When 3/4" (19) or thicker panels are used with a reveal of less than 1/4" (6), door panels may cause damage to the unit when the door is opened to the maximum 105°. Use the built-in 90° door stop.
Integrated Refrigeration
61 subzero. com/specs
Cabinetry Applications
The illustrations below show typical applications of framed and frameless cabinetry. Refer to the full-scale templates at the end of this section for specifics on door openings.
Dual Installations
Two integrated units may be placed side by side in a dual installation. Depending on the models specified, opening widths will be 54" (1372), 63" (1600) or 72" (1829). A reveal of up to 1/4" (6) is possible with adjustments to panel dimensions.
CABINET
INTEGRATED UNIT
CABINET
INTEGRATED UNIT
Typical Panel Dimensions
COLUMN MODELS W H
Door
27" (686) MODELS
DOOR 1/8" (3) REVEAL PANEL DOOR 1/8" (3) REVEAL PANEL
26 13/16" (681)
W
76 7/8" (1953)
H
FINISHED OPENING
FINISHED OPENING
Door Top Drawer Bottom Drawer
36" (914) MODELS
26 13/16" (681) 26 13/16" (681) 26 13/16" (681)
W
45 3/8" (1153) 13 9/16" (345) 16 11/16" (424)
H
Framed--full overlay.
Framed--standard overlay.
Door Top Drawer Bottom Drawer
35 13/16" (910) 35 13/16" (910) 35 13/16" (910)
45 3/8" (1153) 13 9/16" (345) 16 11/16" (424)
CABINET
UNIT
CABINET
INTEGRATED UNIT
A dual installation kit is required for installations with 2" (51) or less space between the units. Dual installation kits are available through your authorized Sub-Zero dealer.
IMPORTANT NOTE: If a 27" (686) unit is installed next to a 36" (914) tall unit, the decorative front panels will align, however, the face frames will not. [. . . ] Service will be provided in the home during the normal business hours. This warranty applies only to products installed for normal residential use. Details regarding a non-residential warranty are available upon request. The warranty applies only to products installed in any one of the fifty states of the United States, the District of Columbia or the ten provinces of Canada. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO DESIGN
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO DESIGN will begin.