User manual SUB-ZERO 700BC-PS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SUB-ZERO 700BC-PS. We hope that this SUB-ZERO 700BC-PS user guide will be useful to you.


SUB-ZERO 700BC-PS : Download the complete user guide (156 Ko)

Manual abstract: user guide SUB-ZERO 700BC-PS

Detailed instructions for use are in the User's Guide.

[. . . ] IMPORTANT NOTE: The depth of Model 700BC(I) is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. The anti-tip bracket must be installed to prevent the unit from tipping forward. [. . . ] Refer to the installation illustration on page 4 for placement of the water line. Regardless of the routing, allow for 27" (686) of excess copper tubing to remain outside the wall or floor for easy connection to the unit, as shown in the installation illustration on page 4. A 115 volt, 6OHz, 15 amp circuit breaker and electrical supply are required. All Integrated models are equipped with a power supply cord with a 3-prong grounding plug, which must be plugged into a mating 3-prong grounding type wall receptacle. The electrical outlet must be placed so the grounding prong is to the right of the thinner blades. Locate electrical within the shaded area shown in the installation illustration on page 4. Do not under any circumstances remove the power supply cord ground prong. In addition, be aware of local codes and ordinances when installing your service. The Integrated Refrigeration Installation Instructions packed with the appliance will give you step-by-step procedures for making sure the unit is installed properly. Dimensions in parentheses are in millimeters unless otherwise specified. 5 Planning Information Integrated Model 700BC(I) C A B I N E T RY A P P L I C AT I O N S Integrated refrigeration is compatible with virtually any style and look of cabinetry. Because of the precise application and the look you may want to achieve, there are important questions you need to answer before ordering panels for the drawers. As you look at styles of cabinets, keep some important facts in mind: IMPORTANT NOTE: The depth of each Integrated unit is 24" (610) from the front of the unit to its back. You must allow for the thickness of the panel you are applying when planning for the finished rough opening depth if you want the front panel to be flush with surrounding cabinetry. You may have to move the unit back into drywall or bring the cabinets forward to achieve a flush fit. Weight Limitations ­ The weight of each drawer panel cannot exceed 12 lbs (5 kg). Panel Thickness ­ Drawer panels must be a minimum of 5/8" (16) thick. The toe kick clearance can vary with the height of the lower drawer panel; the maximum panel height is 16 11/16" (424). You must keep a minimum space of 4" (102) clear below the bottom edge of the lower drawer panel so the unit can be properly vented. IMPORTANT NOTE: The inside edges of the rough opening, as well as the sides and a portion of the backside of the decorative panels will need to be finished, as they will be exposed when the drawers are open. [. . . ] Refer to the illustrations. C CABINETS 25 (635) 2 27 (686) MINIMUM 5/8" (16) SIDE PANELS D UA L I N S TA L L AT I O N S Installation with side panels. CABINETS 25 (635) If two or more Integrated models are installed side by side where there is 2" (51) or less of space between the units, a heater kit is recommended-- BBDUAL for two drawer units installed side by side or a drawer unit and a tall unit installed side by side. To obtain local dealer information, visit the Locator section of our website, subzero. com. T 54 (1372) TOP VIEW Installation of two units side by side. C CABINETS 25 (635) 2 M 27 (686) MINIMUM 5/8" (16) SIDE PANELS Installation at end of run. Dimensions in parentheses are in millimeters unless otherwise specified. 10 Planning Information Integrated Model 700BC(I) TOE KICK CLEARANCE The toe kick clearance can vary with the height of the lower drawer panel; the maximum panel height is 16 11/16" (424). IMPORTANT NOTE: You must keep a minimum space of 4" (102) clear below the bottom edge of the lower drawer panel so the unit can be properly vented. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO 700BC-PS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO 700BC-PS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.