User manual SUB-ZERO 36DUALFUELRANGE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SUB-ZERO 36DUALFUELRANGE. We hope that this SUB-ZERO 36DUALFUELRANGE user guide will be useful to you.


SUB-ZERO 36DUALFUELRANGE : Download the complete user guide (224 Ko)

Manual abstract: user guide SUB-ZERO 36DUALFUELRANGE

Detailed instructions for use are in the User's Guide.

[. . . ] Planning Information 36" (914) Dual Fuel Ranges MODELS DF366 / DF364C / DF364G Dual-stacked, sealed burners Model DF366 Infrared griddle (optional) Continuous cast iron top grates Stainless steel island trim Model DF364C Griddle indicator light Control knobs with platinum bezels Location of rating plate Model DF364G Pivoting hidden control panel Coaxial oven selector knob Dual halogen oven lighting Stainless steel exterior finish Blue porcelain oven interior Spring / damper door system Adjustable front legs and rear casters Dual convection oven Model DF364G shown The Wolf 36" (914) dual fuel range is available in natural or LP gas, with your choice of three top configurations. The model number followed by (-LP) denotes an LP gas model. With Wolf's dual fuel ranges you have state-of-the-art cooking expertise in any number of sizes to meet the discriminating consumers' precise needs. [. . . ] Dimensions in parentheses are in millimeters unless otherwise specified. 2 Planning Information 36" (914) Dual Fuel Ranges MODELS DF366 / DF364C / DF364G MODEL OPTIONS S P E C I F I C AT I O N S Six Burners Four Burners / Charbroiler Four Burners / Griddle DF366 DF364C DF364G Overall Range Width Overall Range Height (to cooking surface) Overall Range Depth 35 7/8" (911) 36 7/8" (937) 29 1/2" (749) Natural gas models listed, for LP gas add (-LP) to the model number. V E N T I L AT I O N O P T I O N S 36" (914) Pro wall hood or liner 42" (1067) Pro wall or island hood Refer to the Wolf Pro Ventilation section for additional information. Dual-Stacked Sealed Surface Burners 15, 000 Btu/hr (4. 4 kW) burners with 950 Btu/hr (. 3 kW) delivered at simmer Single 9, 200 Btu/hr (2. 7 kW) burner with 325 Btu/hr (. 1 kW) delivered at simmer Infrared Charbroiler Infrared Griddle ­ Natural Gas LP Gas Usable Oven Interior Capacity* 16, 000 Btu/hr (4. 7 kW) 15, 000 Btu/hr (4. 4 kW) 13, 000 Btu/hr (3. 8 kW) 3. 4 cu ft (96 L) x 16 1/2" H x 16 3/8" D (673 x 419 x 416) ACCESSORIES Oven Interior Dimensions 26 1/2" W 5" (127) and 10" (254) classic stainless steel risers 20" (508) classic stainless steel riser with shelf Red or black control knobs-- must be ordered with the range Chrome or brass bezels One-piece wok grate and single burner grate Porcelain-coated, cast iron two burner S-grate Hardwood cutting board--griddle model only Two-piece broiler pan and temperature probe Set of three 36" (914) oven racks Bake stone accessory Dehydration accessory Front leg extension covers and rear leg caster covers in various heights High altitude conversion kit Accessories are available through your Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance. com. Electrical Supply Requirements Electric Rating Total Amps Shipping Weight 240 / 208 V AC, 60 Hz 30 amp dedicated circuit 5. 2 kW at 240 V 4. 5 kW at 208 V 21. 7 445 (202 kg) ­ 470 lbs (213 kg) *Oven capacity is calculated using new AHAM standards (AHAM OV-1-2005). IMPORTANT NOTE: A minimum 10" (254) riser is required when installing a 36" (914) dual fuel range with a charbroiler or griddle against a combustible surface. Dimensions in parentheses are in millimeters unless otherwise specified. 3 Planning Information 36" (914) Dual Fuel Ranges MODELS DF366 / DF364C / DF364G I N S TA L L AT I O N S P E C I F I C AT I O N S VENTILATION HOOD 36"min (914) COUNTERTOP TO COMBUSTIBLE MATERIALS 6"min (152) 44"min (1118) FOR CHARBROILER TO COMBUSTIBLE MATERIALS (BOTH SIDES) 30"min (762) TO 36"max (914) TO BOTTOM OF VENTILATION HOOD 13" max (330) 18"min (457) TO COUNTERTOP 36" (914) FINISHED ROUGH OPENING WIDTH 36" (914) 36 7/8" 15" (381) LOCATION OF GAS SUPPLY (937) TO COOKING SURFACE 81/2" (216) 31/4" (83) LOCATION OF GAS AND ELECTRICAL EXTENDS 3" (76) ON FLOOR FROM BACK WALL 19" (483) LOCATION OF ELECTRICAL ISLAND INSTALLATIONS: 12" (305) MINIMUM CLEARANCE FROM BACK OF RANGE TO COMBUSTIBLE REAR WALL ABOVE COUNTERTOP­ 0" (0) TO NON-COMBUSTIBLE MATERIALS DIMENSIONS Overall Width of Range Finished Rough Opening Width Location of Gas Supply Location of Electrical See Installation Instructions shipped with unit for detailed specifications. 35 7/8" (911) 36" (914) Within shaded area Within shaded area Dimensions in parentheses are in millimeters unless otherwise specified. 4 Planning Information 36" (914) Dual Fuel Ranges MODELS DF366 / DF364C / DF364G I N S TA L L AT I O N N OT E S Refer to the illustrations and specifications for overall dimensions, finished rough opening dimensions and installation specifics. IMPORTANT NOTE: Caution must be used in planning the proper installation of the Wolf dual fuel range to avoid any fires or damage to adjacent cabinetry or kitchen equipment. Please follow the minimum clearances established in the finished rough opening dimensions as shown in the installation illustration. IMPORTANT NOTE: A minimum 10" (254) riser is required when installing a 36" (914) dual fuel range with a charbroiler or griddle against a combustible surface. It is recommended that you use a Wolf Pro wall or island ventilation hood or hood liner with the Wolf dual fuel range. Pro Ventilation information can be found on our website, wolfappliance. com. Also refer to the Wolf Design Guide for Pro ventilation recommendations. Wolf dual fuel ranges are designed to operate on natural gas at 5" (12. 5 mb) WC (water column) pressure or LP (propane) gas at 10" (25 mb) WC pressure. The minimum line pressure for natural gas is 7" (17. 5 mb) WC and 11" (27. 4 mb) WC for LP gas. The maximum gas supply pressure to the regulator should never exceed 14" (34. 9 mb) WC; . 5 psi (3. 5 kPa). IMPORTANT NOTE: A separate external gas shut-off valve must be located near the range in an accessible location. Wolf dual fuel ranges using natural gas function up to an altitude of 8, 000' (2438 m) without any adjustment. Natural gas and LP gas installations from 8, 000' (2438 m) to 11, 000' (3353 m) need the high altitude kit. [. . . ] In addition, be aware of local codes and ordinances when installing your services. Refer to the installation instructions shipped with each Wolf product for detailed specifications. Dimensions in parentheses are in millimeters unless otherwise specified. 5 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO 36DUALFUELRANGE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO 36DUALFUELRANGE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.