If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SUB-ZERO 36DUALFUELRANGE. We hope that this SUB-ZERO 36DUALFUELRANGE user guide will be useful to you.
Manual abstract: user guide SUB-ZERO 36DUALFUELRANGE
Detailed instructions for use are in the User's Guide.
[. . . ] Planning Information
36" (914) Dual Fuel Ranges
MODELS DF366 / DF364C / DF364G
Dual-stacked, sealed burners Model DF366
Infrared griddle (optional)
Continuous cast iron top grates
Stainless steel island trim
Model DF364C Griddle indicator light
Control knobs with platinum bezels Location of rating plate
Model DF364G
Pivoting hidden control panel
Coaxial oven selector knob
Dual halogen oven lighting
Stainless steel exterior finish
Blue porcelain oven interior
Spring / damper door system
Adjustable front legs and rear casters
Dual convection oven
Model DF364G shown
The Wolf 36" (914) dual fuel range is available in natural or LP gas, with your choice of three top configurations. The model number followed by (-LP) denotes an LP gas model.
With Wolf's dual fuel ranges you have state-of-the-art
cooking expertise in any number of sizes to meet the discriminating consumers' precise needs. [. . . ] Dimensions in parentheses are in millimeters unless otherwise specified.
2
Planning Information
36" (914) Dual Fuel Ranges
MODELS DF366 / DF364C / DF364G MODEL OPTIONS S P E C I F I C AT I O N S
Six Burners Four Burners / Charbroiler Four Burners / Griddle
DF366 DF364C DF364G
Overall Range Width Overall Range Height (to cooking surface) Overall Range Depth
35 7/8" (911) 36 7/8" (937) 29 1/2" (749)
Natural gas models listed, for LP gas add (-LP) to the model number.
V E N T I L AT I O N O P T I O N S
36" (914) Pro wall hood or liner 42" (1067) Pro wall or island hood
Refer to the Wolf Pro Ventilation section for additional information.
Dual-Stacked Sealed Surface Burners 15, 000 Btu/hr (4. 4 kW) burners with 950 Btu/hr (. 3 kW) delivered at simmer Single 9, 200 Btu/hr (2. 7 kW) burner with 325 Btu/hr (. 1 kW) delivered at simmer Infrared Charbroiler Infrared Griddle Natural Gas LP Gas Usable Oven Interior Capacity* 16, 000 Btu/hr (4. 7 kW) 15, 000 Btu/hr (4. 4 kW) 13, 000 Btu/hr (3. 8 kW) 3. 4 cu ft (96 L) x 16 1/2" H x 16 3/8" D (673 x 419 x 416)
ACCESSORIES
Oven Interior Dimensions
26 1/2" W
5" (127) and 10" (254) classic stainless steel risers 20" (508) classic stainless steel riser with shelf Red or black control knobs-- must be ordered with the range Chrome or brass bezels One-piece wok grate and single burner grate Porcelain-coated, cast iron two burner S-grate Hardwood cutting board--griddle model only Two-piece broiler pan and temperature probe Set of three 36" (914) oven racks Bake stone accessory Dehydration accessory Front leg extension covers and rear leg caster covers in various heights High altitude conversion kit
Accessories are available through your Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance. com.
Electrical Supply Requirements Electric Rating Total Amps Shipping Weight
240 / 208 V AC, 60 Hz 30 amp dedicated circuit 5. 2 kW at 240 V 4. 5 kW at 208 V 21. 7
445 (202 kg) 470 lbs (213 kg)
*Oven capacity is calculated using new AHAM standards (AHAM OV-1-2005). IMPORTANT NOTE: A minimum 10" (254) riser is required when installing a 36" (914) dual fuel range with a charbroiler or griddle against a combustible surface.
Dimensions in parentheses are in millimeters unless otherwise specified.
3
Planning Information
36" (914) Dual Fuel Ranges
MODELS DF366 / DF364C / DF364G I N S TA L L AT I O N S P E C I F I C AT I O N S
VENTILATION HOOD
36"min (914) COUNTERTOP TO COMBUSTIBLE MATERIALS 6"min (152) 44"min (1118)
FOR CHARBROILER TO COMBUSTIBLE MATERIALS (BOTH SIDES)
30"min (762) TO 36"max (914)
TO BOTTOM OF VENTILATION HOOD
13" max
(330)
18"min (457)
TO COUNTERTOP
36" (914) FINISHED ROUGH OPENING WIDTH
36"
(914)
36 7/8" 15" (381) LOCATION OF GAS SUPPLY
(937) TO COOKING SURFACE
81/2"
(216)
31/4"
(83)
LOCATION OF GAS AND ELECTRICAL EXTENDS 3" (76) ON FLOOR FROM BACK WALL
19" (483) LOCATION OF ELECTRICAL
ISLAND INSTALLATIONS: 12" (305) MINIMUM CLEARANCE FROM BACK OF RANGE TO COMBUSTIBLE REAR WALL ABOVE COUNTERTOP 0" (0) TO NON-COMBUSTIBLE MATERIALS
DIMENSIONS
Overall Width of Range Finished Rough Opening Width Location of Gas Supply Location of Electrical
See Installation Instructions shipped with unit for detailed specifications.
35 7/8" (911) 36" (914) Within shaded area Within shaded area
Dimensions in parentheses are in millimeters unless otherwise specified.
4
Planning Information
36" (914) Dual Fuel Ranges
MODELS DF366 / DF364C / DF364G I N S TA L L AT I O N N OT E S
Refer to the illustrations and specifications for overall dimensions, finished rough opening dimensions and installation specifics. IMPORTANT NOTE: Caution must be used in planning the proper installation of the Wolf dual fuel range to avoid any fires or damage to adjacent cabinetry or kitchen equipment. Please follow the minimum clearances established in the finished rough opening dimensions as shown in the installation illustration. IMPORTANT NOTE: A minimum 10" (254) riser is required when installing a 36" (914) dual fuel range with a charbroiler or griddle against a combustible surface. It is recommended that you use a Wolf Pro wall or island ventilation hood or hood liner with the Wolf dual fuel range. Pro Ventilation information can be found on our website, wolfappliance. com. Also refer to the Wolf Design Guide for Pro ventilation recommendations. Wolf dual fuel ranges are designed to operate on natural gas at 5" (12. 5 mb) WC (water column) pressure or LP (propane) gas at 10" (25 mb) WC pressure. The minimum line pressure for natural gas is 7" (17. 5 mb) WC and 11" (27. 4 mb) WC for LP gas. The maximum gas supply pressure to the regulator should never exceed 14" (34. 9 mb) WC; . 5 psi (3. 5 kPa). IMPORTANT NOTE: A separate external gas shut-off valve must be located near the range in an accessible location.
Wolf dual fuel ranges using natural gas function up to an altitude of 8, 000' (2438 m) without any adjustment. Natural gas and LP gas installations from 8, 000' (2438 m) to 11, 000' (3353 m) need the high altitude kit. [. . . ] In addition, be aware of local codes and ordinances when installing your services. Refer to the installation instructions shipped with each Wolf product for detailed specifications.
Dimensions in parentheses are in millimeters unless otherwise specified.