User manual SUB-ZERO 30SEALEDRANGETOP

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SUB-ZERO 30SEALEDRANGETOP. We hope that this SUB-ZERO 30SEALEDRANGETOP user guide will be useful to you.


SUB-ZERO 30SEALEDRANGETOP : Download the complete user guide (217 Ko)

Manual abstract: user guide SUB-ZERO 30SEALEDRANGETOP

Detailed instructions for use are in the User's Guide.

[. . . ] Planning Information 30" (762) Sealed Burner Rangetop Low-profile island trim Continuous, cast iron top grates Model SRT304 Dual-stacked, sealed burners Stainless steel exterior finish Control knobs with platinum bezels Location of rating plate This appliance is certified by Star-K to meet strict religious regulations in conjunction with specific instructions found on www. star-k. org. The Wolf 30" (762) sealed burner rangetop is available in natural or LP gas with a top configuration of four surface burners. The model number followed by (-LP) denotes an LP gas model. There's a good reason why professional chefs choose gas cooking; control. [. . . ] To obtain local dealer information, visit the Locator section of our website, wolfappliance. com. Specifications are subject to change without notice. Dimensions in parentheses are in millimeters unless otherwise specified. 3 Planning Information 30" (762) Sealed Burner Rangetop I N S TA L L AT I O N S P E C I F I C AT I O N S VENTILATION HOOD 30"min (762) COUNTERTOP TO COMBUSTIBLE MATERIALS 6"min (152) TO COMBUSTIBLE MATERIALS (BOTH SIDES) 30"min (762) TO 36" max (914) TO BOTTOM OF VENTILATION HOOD 13" max (330) 18"min (457) TO COUNTERTOP COOKING SURFACE 30" (762) OPENING WIDTH 3/4" (19) PLATFORM LOCATION OF GAS AND ELECTRICAL SUPPLY CUT-OUT WITHIN SHADED AREA THROUGH BOTTOM OF PLATFORM 8 1/2" (216) 3/4" (19) PLATFORM 7 1/2" (191) 16" (406) TOP VIEW OF PLATFORM 36" (914) 24" (610) 4" (102) E 16" (406) BACK WALL G ISLAND INSTALLATIONS: 12" (305) MINIMUM CLEARANCE FROM BACK OF RANGETOP TO COMBUSTIBLE REAR WALL ABOVE COUNTERTOP­ 0" (0) TO NON-COMBUSTIBLE MATERIALS DIMENSIONS Rough Opening Width Rough Opening Height Rough Opening Depth Location of Electrical and Gas Supply See Installation Instructions shipped with unit for detailed specifications. 30" (762) 7 1/2" (191) 24" (610) Within shaded area Dimensions in parentheses are in millimeters unless otherwise specified. 4 Planning Information 30" (762) Sealed Burner Rangetop I N S TA L L AT I O N N OT E S Refer to the illustrations and specifications for overall dimensions, finished rough opening dimensions and installation specifics. IMPORTANT NOTE: Caution must be used in planning the proper installation of the Wolf sealed burner rangetop to avoid any fires or damage to adjacent cabinetry or kitchen equipment. Follow the minimum clearances established in the finished rough opening dimensions as shown in the Installation illustration. The platform for the rangetop must be 3/4" (19) thick and include a cut-out at the right rear for gas supply and electrical connections. The platform must be level to ensure that the cooking surface is level. It is recommended that you use a Wolf Pro wall or island ventilation hood or hood liner with the Wolf sealed burner rangetop. Refer to the Pro Ventilation section of our website, wolfappliance. com. The Wolf sealed burner rangetop requires a 110/120 V AC, 50/60 Hz electrical supply to operate the electronic ignition system. The power supply cord is equipped with a 3-prong, grounded plug for protection against shock hazard. Locate electrical and gas supply within the shaded area shown in the Installation illustration. IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation. Wolf sealed burner rangetops are designed to operate on natural gas at 5" (12. 5 mb) WC (water column) pressure or LP (propane) gas at 10" (25 mb) WC pressure. The minimum line pressure for natural gas is 7" (17. 5 mb) WC and 11" (27. 4 mb) WC for LP gas. [. . . ] In addition, be aware of local codes and ordinances when installing your services. Refer to the installation instructions shipped with each Wolf product for detailed specifications. Dimensions in parentheses are in millimeters unless otherwise specified. 5 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO 30SEALEDRANGETOP




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO 30SEALEDRANGETOP will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.