User manual SUB-ZERO 15GASCOOKTOP

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SUB-ZERO 15GASCOOKTOP. We hope that this SUB-ZERO 15GASCOOKTOP user guide will be useful to you.


SUB-ZERO 15GASCOOKTOP : Download the complete user guide (292 Ko)

Manual abstract: user guide SUB-ZERO 15GASCOOKTOP

Detailed instructions for use are in the User's Guide.

[. . . ] Merely turn down the illuminated knob and the lower-tier burners delivers finetuning control and True Simmer. This patented feature allows you to have the slightest of flame and enjoy a simmer with no boiling or scorching. The sealed burners and deep recess of the seamless drawn pan area make clean up of any of those previously unsightly spills a snap. [. . . ] A Wolf downdraft system, Cooktop or Pro ventilation hood is recommended. When installing a ventilation hood, refer to the specific requirements of the hood for the minimum dimension to the countertop. Also refer to Ventilation Recommendations in the Cooktop Ventilation or Pro Ventilation sections of our website, wolfappliance. com. The Wolf 15" (381) gas cooktop requires a separate 120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker and a grounded 3-prong receptacle should be located within the reach of the 6' (1. 8 m) power cord. Locate electrical within the shaded area shown in the Installation Specifications illustration on page 4. iIMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation. For the 15" (381) gas cooktop, the gas service may be supplied through the floor if the cooktop is not installed above an oven. Refer to the Installation Specifications illustration on page 4 for placement of electrical and gas supply. Wolf gas cooktops are designed to operate on natural gas at 5" (12. 5 mb) WC (water column) pressure or LP (propane) gas at 10" (25 mb) WC pressure. The minimum line pressure for natural gas is 7" (17. 5 mb) WC and 11" (27. 4 mb) WC for LP gas. The maximum gas supply pressure to the regulator should never exceed 14" (34. 9 mb) WC; . 5 psi (3. 5 kPa). The cooktops are supplied with a 1/2" NPT male gas connection at the right rear bottom corner of the cooktop. The male connector exits the unit straight down and you are supplied with a regulator with two female connectors. Wolf gas cooktops using natural gas function up to an altitude of 8, 000' (2438 m) without any adjustment. Natural gas installations from 8, 000' (2438 m) to 10, 000' (3048 m) need the high altitude conversion kit. LP gas installations will operate up to 10, 000' (3048 m) without adjustment. [. . . ] When multiple gas cooktops and/or modules are installed next to one another, they can receive their gas supply from a common line. However, each unit must have its own regulator installed between the mainline and the cooktop or module. When two or more cooktops or modules are installed together, an integrated module filler strip is recommended. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO 15GASCOOKTOP




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO 15GASCOOKTOP will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.