User manual STUV 16-IN ASSEMBLY OF A FAN

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual STUV 16-IN. We hope that this STUV 16-IN user guide will be useful to you.


STUV 16-IN ASSEMBLY OF A FAN: Download the complete user guide (1491 Ko)

You may also download the following manuals related to this product:

   STUV 16-IN (1581 ko)
   STUV 16-IN INSTALLATION (3325 ko)

Manual abstract: user guide STUV 16-INASSEMBLY OF A FAN

Detailed instructions for use are in the User's Guide.

[. . . ] Stûv 16-in or 16-cube version QA1 the serial number of which is higher than 73074 - production date: June 2009. There are two different fan kits ­ the 12017008 kit for the Stûv 16-cube installed on a Stûv base [photo 1] ­ the 12017006 kit in all other cases. These kits are only intended for Stûv 16 fires whose serial number is higher than 73074 ­ production date: June 2009. [. . . ] If installing on a Stûv base, cable guides are provided (one already assembled, another in the fittings packet). Attach the electronic circuit under the front part of the fan access cover using 2 M4 x 8 screws with hexagonal heads [photo 3]. Attach the back cover at the same time as the side parts [a] forming the mouth of the fan using the 2 M4 x 12 screws. Connection of the power supply and earth Connect the cables to the circuit; the terminal blocks can be disconnected from the electronic circuit [photo 5]. The connection indications are marked on the underside of the terminal blocks (power supply, earth, speed 1, 2, ). Connect the power supply [photo 6-a] and the earth to the circuit's metal support [photo 7]. Strip the cable with 4 wires and clean the sheath of each wire; you will see that each of the wires is numbered. Connect to the terminal block [photo 9-c] by following the indications of the wiring scheme [8]. If the pressure loss in the fan circuit [diagram 10] is low (A + B < 3m)*, the factory settings are correct: The "jumper" [photo 11 and diagram 12] is properly positioned (J2 side, on the left). If, on the other hand, the ducts are longer (A + B > 3m)*, the fan will require more power to overcome the pressure loss: Remove the jumper and put it onto the 2 straight pointers (C17 side). The thermal switch only allows power to the fan when the temperature of the reheated air is high enough. Therefore, when lighting, the fan will only start after a few minutes to prevent unpleasant currents of cold air. With installation on a Stûv base, attach all the cables together using the brackets provided to the right lug of the support [photos 14 and 15] to keep them away from the fan. Close the side openings using the 2 corresponding sealing plates and attach them (size 2. [. . . ] Cut it by 10 cm for the 16/68 to a length of 50cm - and by 20 cm for the 16/58 to a length of 40cm Put the metal wire into the seal to make it easier to position [photo 2]. Insert the seal behind the valve mechanism between the stove and the plate [photo 3]. However, we do not accept responsibility for any errors that may have been made. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE STUV 16-IN




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual STUV 16-IN will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.