User manual SPEEDOTRON BLACK LINE EQUIPMENT

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SPEEDOTRON BLACK LINE EQUIPMENT. We hope that this SPEEDOTRON BLACK LINE EQUIPMENT user guide will be useful to you.


SPEEDOTRON BLACK LINE EQUIPMENT : Download the complete user guide (1110 Ko)

Manual abstract: user guide SPEEDOTRON BLACK LINE EQUIPMENT

Detailed instructions for use are in the User's Guide.

[. . . ] Welcome to Speedotron Thank you for purchasing Speedotron Black Line equipment. The name Speedotron is synonymous with professional workmanship and the finest electronic flash equipment available. Backed by years of experience, our engineers have developed the Black Line system to take the rigors of daily professional use with consistently outstanding results. For more than 50 years, Speedotron's reputation has grown without much fanfare or advertising. [. . . ] (The beep will not be produced when a very small power change is made. Changing the power level by a third f-stop or so is done very rapidly with the 2403CX; the Ready light will usually remain on) The power supply is now charged to the selected level, and ready to fire. Do not immediately fire the unit on the first use or when the unit has been idle for periods over 3 weeks. Push to Flash button may be depressed to verify proper system operation. When Power is on, be sure Ready indicator is illuminated before switching Power or Fast/Slow. The 2403CX power supply will automatically discharge its storage capacitors. Unplug power cord from outlet, then disconnect light units from power supply. 5 6 3 2 4 1 2403CX Description of Controls 1) Power -- turns power supply on and off. 3) 800Ws Isolate/Combine -- when in isolate, this switch isolates the 800Ws channel from the 1200Ws channel and provides two Light Unit Outlets per channel. 4) 400Ws Isolate/Combine -- when in isolate, this switch isolates the 400Ws channel from the 1200Ws channel and provides two Light Unit Outlets per channel. (With both 800Ws and the 400Ws switches in combine, 2400Ws is available through any of the six Light Unit Outlets, divided equally. See diagrams on the side of the power supply and page 15 for detailed examples of the ratio system). 5) Variable Power Control -- simultaneously controls power of all three channels, with ten positions down to -3 stops (1/8 power). Power ratios among the light units are unaffected since there is a proportional change in all power levels. 7)Charge/Ready/Push to Flash -- red Charge light is illuminated whenever the power supply is charging up or down to the selected level. Green Ready light is lit whenever the 2403CX is fully charged to the selected power level. Push to Flash button is for manual triggering of flash for testing or open flash application. 8) Remote -- for use with optional Remote Variable Power Control (#11237) to allow exposure bracketing from the camera position. The Variable Power Control must be in the full position for the power levels to be correctly indicated by the remote control. 16 2403CX Power Ratios Power ratio information for the 2403CX Power supply can be found on page 15 under 2401CX/SX & 2403CX Power Ratios. 17 2403CX · power supply 7 4803CX · power supply 9 5 6 3 8 11 10 4803CX Operating Instructions The following sequence of operation should be utilized for maximum life and dependability of the 4803CX power supply. 2 4 1 Make sure that the Model and Power switches are in the off position and the Reset button (circuit breaker) is fully depressed into its socket. Connect light unit cable(s) to the Light Unit Outlet(s) on the power supply, selecting the appropriate outlet(s) for the desired power level. Any Black Line Universal Light Unit may be attached to the left and center Light Unit Outlets. Only Model 206VF light units may be attached to the right Light Unit Outlets. (See Universal Light Units section of this manual for information on assembling light units. ) Set Isolate/Combine switches and Variable Power Control as desired. [. . . ] Service under this agreement will be performed only at the Speedotron factory in Chicago. Service performed at any other service station, including those authorized by Speedotron, is not covered and any service so performed is at the customers expense. Shipping charges, both to and from the Chicago factory, are also the responsibility of the customer, and are not covered by this agreement. Shipping charges to cover the return of your equipment by what-ever means you choose may be included with requests for service, or equipment can be returned C. O. D. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SPEEDOTRON BLACK LINE EQUIPMENT




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SPEEDOTRON BLACK LINE EQUIPMENT will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.