User manual SOMFY 5012940

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SOMFY 5012940. We hope that this SOMFY 5012940 user guide will be useful to you.


SOMFY 5012940 : Download the complete user guide (1984 Ko)

You may also download the following manuals related to this product:

   SOMFY 5012940 (876 ko)

Manual abstract: user guide SOMFY 5012940

Detailed instructions for use are in the User's Guide.

[. . . ] This box is used to bring into compliance the doors fitted on industrial, commercial premises and garages in relation to the new European standards (NF EN 12445, NEF EN 12453, EN 12978, EN 13241) and French standards (NF P25 362). Hereby, SOMFY, declares that this equipment is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. The 24V control box is intended to control one or two DC motor(s) to open and close gates. [. . . ] The 24V control box is intended to control one or two DC motor(s) to open and close gates. It may be equipped with other safety devices, such as photoelectric cells. Any detection during closure causes stopping then reopening (total or partial, depending on parameter A1). Any detection during opening causes stopping then closue (total or partial, depending on parameter A0). Parameter settings activate the following safety devices: - Detection before opening the gate excludes all movement. Correct operation of the safety devices can be checked (parameter A2 to A6) at the end of each opening/closing cycle. When the gate is in movement, 2 outputs control the following devices: Control Area lighting Orange light Contact Dry contact Vmax: 230Vac - Pmax: 150Va Output 2 x 15 w (sequence control) According to the parameter settings (parameter Po), the 24V control box has several operating modes: Modes Automatic/Blockage/Senquenced+timed: Compulsory installation of safety accessorie. Blockage After the gate is opened, passage in front of the closing security cells closes the gate after a SEC. After parameter setting, check the good fonctionning of safety accessories. To be taken into account, all modified values must be validated by pressing this key. Auto learning is used to measure the stroke, the opening angles of the leaves, to assign the speeds and offsets so that the dor can operate after auto learning. Need (except value 05 which is prohibited) and the auto learning `P3' to `01'. Generate an opening command via the outer command or the radio (after programming it). The door leaf(ves) should open and check the covering leaf (cable on M1) starts first, otherwise, · When the display indicates ` H1', generate a new command to close. All these parameters may be modified after learning to make the door movement more precise. 2 · For very fragile doors, it is possible to perform auto learning at a reduced torque by reducing the value of parameters `P4 and P5' immediately after setting the auto learning parameter ` P3' to `01' and before executing the opening command. [. . . ] All these parameters may be modified after learning to make the door movement more precise. 2 · For very fragile doors, it is possible to perform auto learning at a reduced torque by reducing the value of parameters `P4 and P5' immediately after setting the auto learning parameter ` P3' to `01' and before executing the opening command. 3 · Learning will only be completed after a complete closing movement. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SOMFY 5012940




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SOMFY 5012940 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.