User manual SLANT FIN GF-300

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SLANT FIN GF-300. We hope that this SLANT FIN GF-300 user guide will be useful to you.


SLANT FIN GF-300 : Download the complete user guide (71 Ko)

Manual abstract: user guide SLANT FIN GF-300

Detailed instructions for use are in the User's Guide.

[. . . ] DO NOT clean the product or service the UV germicidal bulb without disconnecting the power cord. Before connecting to electric power outlet, check your electrical power supply. The circuit must be of adequate size and must be protected by fuse or circuit breaker. 2 16. As a safety feature, this plug will fit in a polarized electrical receptacle (outlet) only one way. [. . . ] The useful life of the mineral absorption pad will vary, depending on the mineral content of the water used. In areas of moderate mineral content water supply, the mineral absorption pad should be changed after approximately (3) weeks of continuous use. If the water is "Hard Water", the pad should be changed more frequently. The best way to tell when the pad should be changed is to examine it AFTER the water has cooled down, to see if it is still soft and pliable. When the pad is near the end of its life, it becomes stiff and hard and should be replaced with a new pad. Another sign to change pad is when scale begins to buildup on interior of hot water reservoir. 5. 6. CLEANING AND MAINTENANCE Water contains minerals and other particles. During operation most of these minerals will remain in the water reservoir. Gradual buildup of deposits will coat the hot water reservoir and reduce its efficiency. The importance of routine cleaning and care cannot be over-emphasized. Hard water contains more minerals and other particles. 7. CLEANING INSTRUCTIONS Failure to perform the necessary cleaning steps will damage unit. Before cleaning, set CONTROLS to "OFF" position and unplug unit. Allow at least 15 minutes after shutting unit "OFF" before moving base. 6 8. 9. Rotate steam diffuser counterclockwise until steam diffuser slots line up with tabs in base, and lift up. Rotate steam dome until steam dome slots line up with tabs in base and lift out. Remove mineral absorption pad from hot water reservoir using tweezers or tongs to prevent burns from hot water. When the cleaning procedure is completed, replace mineral absorption pad. To drain water from humidifier base, grasp with both hands and tilt to the side, draining water into the sink. BE CAREFUL NOT TO HAVE DRAINING WATER FALL INTO CONTROLS OR VENT OPENINGS. Turn the base upside down and remove the drain tube cap by turning it counterclockwise. Clean out any foreign matter that has accumulated inside the fitting from which the cap was removed. Pour a small amount of water into the hot water reservoir and check for leaks from this cap under the base. [. . . ] UV bulb replacement is a normal maintenance procedure and is therefore not covered under this warranty unless the bulb is found to be defective. For repairs, return humidifier to address shown below with dated sales receipt. Return to: Consumer Service Dept. , Slant/Fin Corporation, 40 Garvies Point Road, Glen Cove, NY 11542. In Canada: Slant/Fin LTD/LTEE, 6450 Northam Drive, Mississauga, Ontario L4V 1H9. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SLANT FIN GF-300




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SLANT FIN GF-300 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.