User manual SIMPSON CS901S

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SIMPSON CS901S. We hope that this SIMPSON CS901S user guide will be useful to you.


SIMPSON CS901S : Download the complete user guide (947 Ko)

Manual abstract: user guide SIMPSON CS901S

Detailed instructions for use are in the User's Guide.

[. . . ] installation guide canopy rangehoods Models: CS601S, CS901S 222mm 165mm 470mm (max. )* 1240mm (max. ) 540mm 230mm 20mm 500mm 600/900mm *1100mm extension flue cover is available if required where high ceilings are present. [. . . ] SRANIDCANOPY 05/06 page 2 of 3 ducting accessories canopy rangehoods Models: CS601S, CS901S AR125R C AR125F Flashing not supplied AR500FS AR125FJ/AR125FJD AR125WV AR125B AR125F D Alternative flue connection AR500RK AR500CF Part Numbers AR125RC AR125B AR125F AR125FD AR125WV AR500FS AR500RK AR500CF AR125FJ AR125FJD Description Roof Cowl 90° Bend Flue 1200mm Long Flexible Duct ­ 1 metre long when expanded Wall Vent Kit Extra Length Flue Cover 1100mm length brushed stainless steel Recirculating Kit (includes AR500CF x 2) Replacement Carbon Filters Flue Joiner without damper Flue Joiner with damper Current as at May 2006. SRANIDCANOPY 05/06 page 3 of 3 installation guide fixed rangehoods Models: RHN6W, RHN6S, RHN9W, RHN9S 300mm 25mm 25mm 30mm 30mm ø119mm 79mm 60mm 100mm 500mm 160mm Minimum distance of hood above hob 25mm 35mm 105mm 143mm 598/898mm GAS: 650mm ELECTRIC: 600mm Rear Exhaust to atmosphere Top Exhaust to atmosphere Side Exhaust to atmosphere Front Recirculating Exhaust* * In recirculating mode you must use carbon filters to eliminate cooking smells. SRANIDFIXED 05/06 page 1 of 2 ducting accessories fixed rangehoods Models: RHN6W, RHN6S, RHN9W, RHN9S AR125RC AR125F Flashing Not Supplied AR125B AR125FD Alternative flue connection AR125FJ/AR125FJD AR125WV Part Numbers AR125RC AR125B AR125F AR125FD AR125WV AR125FJ AR125FJD ARCFD (not illustrated) Description Roof Cowl 90° Bend Flue 1200mm Long Flexible Duct ­ 1 metre long when expanded Wall Vent Kit Flue Joiner without damper Flue Joiner with damper Replacement Carbon Filters Current as at May 2006. SRANIDFIXED 05/06 page 2 of 2 installation guide slideout rangehoods Models: REHR6W, REHR6S 80mm 34mm 121 210mm 100mm 20mm 470mm 158mm 550mm 599mm 42mm 175mm 280mm 458mm 40mm Minimum distance of hood above hob GAS: 650mm ELECTRIC: 600mm Rear Exhaust to atmosphere Top Exhaust to atmosphere Side Exhaust to atmosphere Top Recirculating Exhaust* * In recirculating mode you must use carbon filters to eliminate cooking smells. SRANIDSLIDE60 05/06 page 1 of 2 ducting accessories slideout rangehoods Models: REHR6W, REHR6S AR125RC Flashing Not Supplied AR125F AR125FD (Alternative flue connection) AR125B AR125FJ/AR125FJD AR125WV Part Numbers AR125RC AR125B AR125F AR125FD AR125WV AR125FJ AR125FJD ARCFD (not illustrated) Description Roof Cowl 90° Bend Flue 1200mm Long Flexible Duct ­ 1 metre long when expanded Wall Vent Kit Flue Joiner without damper Flue Joiner with damper Replacement Carbon Filters Current as at May 2006. SRANIDSLIDE60 05/06 page 2 of 2 installation guide slideout rangehoods Models: REHR9W, REHR9S 80mm 34mm 121 100mm 770mm 40mm 20mm 210mm 899. 5mm 850. 5mm 175mm 158mm Minimum distance of hood above hob 280mm 458mm 42mm GAS: 650mm ELECTRIC: 600mm Rear Exhaust to atmosphere Top Exhaust to atmosphere Side Exhaust to atmosphere Top Recirculating Exhaust* * In recirculating mode you must use carbon filters to eliminate cooking smells. [. . . ] SRANIDSLIDE90 05/06 page 1 of 2 ducting accessories slideout rangehoods Models: REHR9W, REHR9S AR125RC Flashing Not Supplied AR125F AR125FD (Alternative flue connection) AR125B AR125FJ/AR125FJD AR125WV Part Numbers AR125RC AR125B AR125F AR125FD AR125WV AR125FJ AR125FJD ARCFD (not illustrated) Description Roof Cowl 90° Bend Flue 1200mm Long Flexible Duct ­ 1 metre long when expanded Wall Vent Kit Flue Joiner without damper Flue Joiner with damper Replacement Carbon Filters Current as at May 2006. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SIMPSON CS901S




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SIMPSON CS901S will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.