User manual SHERWOOD PM-9805

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SHERWOOD PM-9805. We hope that this SHERWOOD PM-9805 user guide will be useful to you.


SHERWOOD PM-9805 : Download the complete user guide (662 Ko)

You may also download the following manuals related to this product:

   SHERWOOD PM-9805 (6377 ko)
   SHERWOOD PM-9805 (5402 ko)
   SHERWOOD PM-9805 (6022 ko)
   SHERWOOD PM-9805 (6234 ko)

Manual abstract: user guide SHERWOOD PM-9805

Detailed instructions for use are in the User's Guide.

[. . . ] · The legs have functions for adjusting the height of the unit itself. The model may not be able to perform at its best in an extremely cold envirnment. The optimum ambient temperature range is 0 oC to 35 oC. OPERATION PRECAUTIONS 1. Always clean the stylus both before and after playing a record with a soft brush, and try to make it a rule to clean the record with a soft brush and try to make it a rule to clean the records with a good quality cleaner. [. . . ] Set the [14] anti-skating control knob to the same value as the stylus. 3 ADJUSTING THE TONEARM Level Balance Adjustment 1. Release the arm clamp and move the tonearm to the space between the arm rest and the platter, taking care not to damage the stylus. Support the headshell's finger-lift with one hand and attain the level balance by turning the counterweight either clockwise or counter-clock wise. "Level balance" means that the tonearm is parallel to the record on the platter, and that the tonearm pipe, therefore, should not tilt toward the counterweight side or the headshell side. Since the tracking force is zero when the tonearm is balanced level, turn just the tracking-foce scale ring in front of the counter-weight, and set the "0" on the scale to the index line on the shaft. When doing so, be sure to hold the counterweight with the other hand so that it does not turn together with the scale ring. NOTE: The MG-2831 cartridge that comes with the set has a tracking force of 2g. Turn the counterweight to the 2 mark. Tracking Force Adjustment Turning the counterweight, set the correct tracking force opposite the index line on the counterweight shaft. The tracking-force scale ring has 0. 25g steps and one full turn of the counterweight will yield a tracking force of 3g. Scale ring Anti-Skating Adjustment To adjust the Anti-skating mechanism, turn the Anti-Skate Knob so that the number corresponding to the required tracking force is opposite the index line. The numbers on the Anti-Skate Knob correspond to 1g of tracking force. 4 CONTROLS AND OPERATION 1. Turn the (On/Off Switch) clockwise to turn on the power, the speed indicator and the strobeilluminator, which is located beneath the On/Off switch, will light up. When playing a 45rpm record with a large center hole, place the 45rpm adapter on the center spindle. Remove the stylus protector from the Headshell Stylus, release the Tonearm clamp. Press the Start/Stop Button, the turntable platter will start to rotate. 7. Set the cueing lever to the down position, the tonearm will descend slowly onto the record and begin playing. When play is finished, raise the cueing lever, move the tonearm onto the Tonearm clamp. Turn the On/Off Switch counterclockwise to turn off the power. SUSPEND PLAY Set the cueing lever to "UP" position during play, the stylus tip of the cartridge will be lifted from the record. 5 CONNECTIONS This set's phono cables and ground lead are attached to the rear panel of the turntable. The phono cable with the white plug is for the left channel and the one with the red plug is for the right channel. The thin wire with the Y-shaped connector at the end is the ground lead. This should be firmly connected to the ground terminal on the mixer. The way in which the phono cables are attached will depend on the type of cartridge used. Read the instructions in the booklet that comes with the cartridge as well as the operating instructions of the mixer and connect the phono cables properly. Finally, plus the power cord into the power consent. 6 8 STYLUS REPLACEMENT CONNECTIONS The life expectancy of the stylus tip is 500 hours. [. . . ] GENERAL SECTION: 5-1 Power Supply 5-2 Power consumption 5-3 Dimensions 5-4 Weight 6. SPECIFICATION: DESCRIPTIONS (1) Output Difference (2) Output Level (3) Speed (Speed range) (4) Speed (Center Range) (5) Wow and Flutter (6) Channel separtion UNIT dB mv Hz Hz % dB AC 230V ~ 50Hz 8 Watts 450(W) 350(D) 4. 38Kgs 139(H) mm NOMINAL 2. 3 1. 7~3. 5 2. 7K , 3. 3K 2970~3030 0. 23 16 LIMIT 2. 5 1. 5~3. 5 2. 7K , 3. 27K 2965~3030 0. 25 15 8 TROUBLE SHOOTING Sometimes, an operational fault can be mistaken for a malfunction or failure. Check the following points and see if you can find the symptoms of the trouble below before you get in touch with the serviceman. If you cannot locate the symptoms, contact your nearest dealer. Symptom Platter does not rotate. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHERWOOD PM-9805




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SHERWOOD PM-9805 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.