User manual SHERWOOD NEWCASTLE P-965

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SHERWOOD NEWCASTLE P-965. We hope that this SHERWOOD NEWCASTLE P-965 user guide will be useful to you.


SHERWOOD NEWCASTLE P-965 : Download the complete user guide (3416 Ko)

You may also download the following manuals related to this product:

   SHERWOOD NEWCASTLE P-965 PRODUCT BROCHURE (504 ko)

Manual abstract: user guide SHERWOOD NEWCASTLE P-965

Detailed instructions for use are in the User's Guide.

[. . . ] P-965 A/V Tuner Pre Amplifier Introduction READ THIS BEFORE OPERATING YOUR UNIT ENGLISH This symbol is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. CAUTION : TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. WARNING : TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. Note to CATV System Installer : This reminder is provided to call the CATV system installer's attention to Article 820-40 of the NEC that provides guidelines for proper grounding and, in particular, specifies that the cable ground shall be connected to the grounding system of the building, as close to the point of cable entry as pracitcal. FCC INFORMATION This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. [. . . ] · Each time this button is pressed, the mode changes as follows : STANDBY POWER ON PAGE MAIN FAV CH. SET VOL CH/ ADJUST or MUTE DECODE DSP DSP RETURN STEREO 1 4 7 DISP 2 5 8 0 M2 3 6 9 OSD/MENU ENT MI M3 RNC-510 DOLBY HEADPHONE 1: This simulates the soundfield as if you were in a relatively small room with less reverberations. DOLBY HEADPHONE 2: This simulates the soundfield as if you were in a typical listening room with moderate reverberations. DOLBY HEADPHONE 3: This simulates the soundfield as if you were in a large space like theater. Off : Depending on the signal format which is being input, either the stereo mode or the 2CH downmix mode is selected. · Combined with the current mode, the selected Dolby Headphone mode is activated. · The desired mode can be selected with pressing the CURSOR UP( ) button only when the OSD menu operation is not performed. Notes : · In case of that the original surround mode is "DOLBY DIGITAL EX" or "DTS ES" mode, it will be automatically changed to "DOLBY DIGITAL" or "DTS" mode. · Only when playing a stereo (2 channel) source in "PL IIx", "DOLBY VS" or "DOLBY HEADPHONE" mode, you can select the original surround mode to be combined with use of the MULTI CONTROL knob or the DSP MODE UP( )/DOWN( ) buttons. (However, in case of "PL IIx" mode, you cannot select "PL II"mode. ) · When "PL IIx" mode is selected while playing in "PL II" mode, it will be automatically changed to "DOLBY DIGITAL" or "BYPASS" mode depending on the signal format which is being input. Selecting the surround back channel mode as connected · You can set the surround back channel mode according to surround back speaker connection. · Each time this button is pressed, the mode changes as follows : STANDBY POWER ON 1 channel : When a surround back speaker is connected. (" SB AUD2 SLEEP DIMM ROOM2 T. TON OSD D/A S. A/B SUR. B PURE " lights up) 2 channel : When two surround back speakers are connected. (" SB PARA. PAGE1 " lights up) None : When surround back speakers are not connected. Note: · When the surround speaker is set to "None", the surround back channel is automatically set to None. 31 ENGLISH To listen in a Dolby Headphone mode · The Dolby Headphone function simulates 5. 1 channel surround sound, which allows you to enjoy 5. 1 channel surround sound through 2 channel headphones, just like listening from 5. 1 channel speakers. Note : Only when the HEADPHONE SELECTOR button is set to the speaker off mode, the Dolby Headphone mode can be selected. Adjusting each channel level with test tone · The volume level of each channel can be adjusted easily with the test tone function. Note: When speakers are switched off , the test tone function does not work. Enter the test tone mode. ENGLISH 1 STANDBY POWER ON · The test tone will be heard from the speaker of each channel for 2 seconds as follows: FL Front Left FC Center FR Front Right SR Surround Right SUB SUBwoofer SL ( SC) or ( BL BR) AUD2 SLEEP DIMM ROOM2 T. TON OSD D/A S. A/B SUR. B PURE Surround Left (Surround Center) (Surr. PAGE1 · Depending on the speaker setting(None or No), the test tone of the corresponding channel is not available. · ( ): possible depending on whether the surround back channel is set to 2 CH or 1 CH. Cancel the test tone function. 2 At each channel, adjust the level as desired until the sound level of each speaker is heard to be equally loud. STANDBY POWER ON 3 STANDBY POWER ON AUD2 SLEEP PAGE D/A S. A/B SUR. B PURE MAIN FAV DIMM CH. SET VOL CH/ ADJUST or DOWN UP MUTE DECODE DSP DSP CH/ ADJUST ROOM2 T. TON OSD PARA. PAGE1 RETURN STEREO 1 4 7 DISP 2 5 8 0 M2 3 6 9 OSD/MENU ENT MI M3 RNC-510 · You can select the desired channel and adjust its level with repeating the steps and in "Adjusting the current channel levels" procedure. Adjusting the current channel levels · After adjusting each channel level with test tone, adjust the channel levels either according to the program sources or to suit your tastes. · If you have performed the CH LEVEL SETUP procedure on the OSD menu, you can memorize the adjusted channel levels into preset memory(PRESET 1, PRESET 2) and recall the memorized whenever you want. (Refer to "SETTING THE CH LEVEL SETUP" on page 61. ) 1 Select the desired channel. · Each time this button is pressed, the corresponding channel is selected as follows: STANDBY POWER ON FRONT-L FRONT-C FRONT-R SURR-R SUBWOOFER PAGE SURR-L ( SURR-C) or ( BACK-L BACK-R) MAIN FAV CH. SEL or DECODE DSP DSP RETURN STEREO 1 4 7 DISP 2 5 8 0 M2 3 6 9 OSD/MENU ENT MI M3 RNC-510 · Depending on the speaker settings and surround mode, etc. , some channels cannot be selected. · ( ): possible depending on whether the surround back channel is set to 2 CH or 1 CH. [. . . ] Then the volume level will be fixed to the adjusted level. 64 When selecting the ROOM 2 FEED mode 1 STANDBY POWER ON STANDBY POWER ON PAGE MAIN FAV CH. SET VOL MUTE CH/ ADJUST DECODE DSP DSP PAGE MAIN FAV CH. SET RETURN STEREO CH/ ADJUST VOL MUTE 1 4 2 5 8 0 M2 3 6 9 OSD/MENU ENT DECODE DSP DSP 7 DISP MI M3 RETURN STEREO RNC-510 1 4 7 DISP 2 5 8 0 M2 3 6 9 OSD/MENU ENT MI M3 · Each time these buttons are pressed, the ROOM 2 FEED mode is changed to "On" or "Off". · When the ROOM 2 FEED mode is set to "Off", the ROOM 2 source cannot be selected. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHERWOOD NEWCASTLE P-965




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SHERWOOD NEWCASTLE P-965 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.