Manual abstract: user guide SHARP ER-A170
Detailed instructions for use are in the User's Guide.
[. . . ] AVISO: El tomacorriente debe estar instalado cerca del equipo y debe quedar bien accesible. VARNING: Det matande vägguttaget skall placeras nära apparaten och vara lätt atkomligt. CAUTION: For a complete electrical disconnection pull out the mains plug. VORSICHT: Zur vollständigen elektrischen Trennung vom Netz den Netzstecker ziehen. [. . . ] Zero skip in clerk report Zero skip in cashier report Zero skip in transaction report Zero skip in department report Zero skip in PLU report Zero skip in hourly report Zero skip in daily net report
Selection: Yes No Yes No Yes No Yes No Yes No Yes No Yes No
Entry: 0 0 1 0 1 0 1 0 1 0 1 0 1 0 1
69
FOR THE MANAGER-2-A410/A420
02. 4. 20 6:49 PM
Page 70
**P: 4 * Item:
A B C D E F G H Always enter 0. VAT/tax amount printing on the receipt/journal Taxable amount printing on the receipt/journal Net amount printing on the receipt/journal Always enter 0. Automatic return timing for PLU level
Selection:
Print Do not print Print Do not print Print Do not print
By one item By one receipt
Entry: 0 0 0 1 0 1 0 1 0 0 0 1
**P: 5 * Item:
A B C D E F G H Always enter 0. VAT shift method PLU price shift method Available mode for PLU price shift PLU price shift mode Automatic return timing for PLU price level
Selection:
By cashier By shift key By shift key By cashier REG and MGR modes MGR mode only Automatic return mode Lock shift mode By one item By one receipt
Entry: 0 0 0 0 1 0 1 0 1 0 1 0 1
**P: 6 * Item:
A B C D E F G H VAT/tax amount printing on the slip Taxable amount printing on the slip Net amount printing on the slip Time printing on the slip Always enter 0. Always enter 0.
Selection: Print Do not print Print Do not print Print Do not print Print Do not print
Entry: 0 1 0 1 0 1 0 1 0 0 0 0
70
FOR THE MANAGER-2-A410/A420
02. 4. 20 6:49 PM
Page 71
**P: 7 * Item:
A B C D E F G H Always enter 0. No sale in REG mode Finalization when the subtotal amount is zero in the REG mode Always enter 0. Always enter 0.
Selection:
Enable Disable Enable Disable
Entry: 0 0 0 1 0 1 0 0 0 0
**P: 8 (ABCDEFGH: Always enter 0. )
**P: 9 * Item: A Always enter 0. B Exchange 1 calculation method (for EURO settings) C D E F G H Cheque/credit operation for exchange 1 Printing of the exchange 1 total amount and change amount on the receipt/journal Printing of the exchange 1 total amount at the total (payment) validation printing Always enter 0. Footer graphic logo printing
Selection: Multiplication Division No Yes No Yes No Yes
No Yes
Entry: 0 0 1 0 1 0 1 0 1 0 0 0 1
Note
The items B and D are automatically set by the operation of job #800 in the X2/Z2 mode.
**P: 10 to 12 (ABCDEFGH: Always enter 0. ) **P: 13 * Item:
A B C D E F G H Credit counting when RA/PO entry is finalized with the credit key Separator line in the report Link PLU printing format Always enter 0. Always enter 0.
Selection: No Yes 1 line space Separator line Master PLU with total amount Each PLU
Entry: 0 1 0 1 0 1 0 0 0 0 0
71
FOR THE MANAGER-2-A410/A420
02. 4. 20 6:49 PM
Page 72
Programming alarm length of time with drawer opening
Procedure
To disable the alarm function 2617
PGM 2
2617
If the drawer still remains open when a specified length of time has elapsed, your machine gives the alarm.
.
Time 1 to 255 seconds
;
Print
Example
Key operation
2617 . 30 ;
Note
Your machine starts to monitor how long the drawer is kept open the moment the drawer is opened at the end of a transaction in the REG/VOID mode. Up to 21 characters can be programmed per line.
Procedure
To keep the current setting 2646
.
No. 1 NAME1 :
;
76
FOR THE MANAGER-2-A410/A420
02. 4. 20 6:49 PM
Page 77
Selection of X1/Z1 and X2/Z2 reports to be printed in the stacked report sequence PGM 2 2620
Your register is equipped with the stacked report printing function that enables multiple X/Z reports to be printed in sequence with only a single request.
Procedure
2620
.
* 1 Job no.
To cancel the stacked report sequence For full reporting (non-range report) For individual reporting
* 2 Start range parameter
* 2 End range parameter
:
;
To program for another Job no.
Note
· Maximum 70 steps are programmable. "1 step" means the memory size used for one no-range type job no. · When Z of stacked report is initiated, X only reports will be skipped.
Job code numbers to be used are as follows.
*1: Job no. 00 10 13 20 24 27 29 30 31 32 40 50 60 70 80 82 Report name General Full department Full department group PLU PLU stock PLU zero sales PLU price category Transaction Total in drawer Commission sales Full clerk Full cashier Hourly sales information Daily net report PBLU report Balance report *2: Start/End range parameter Note
*3 Start PLU code/End PLU code (1 through 999999) *3 Start PLU code/End PLU code (1 through 999999) *3 Start price amount/End price amount
*3 Start time/End time (0 through 2330)
Range report is available only in the X1 mode.
*3 Start PLU code/End PLU code (1 through 9999)
*3: Both range setting and full setting are allowed.
Example
Key operation
Print
2620 . 10 : 13 :
;
77
FOR THE MANAGER-2-A410/A420
02. 4. 20 6:49 PM
Page 78
Setting the time range for hourly reports
You can set the time range for an hourly report.
PGM 2
2619
Procedure
When A through C are all zeros 2619
.
* ABC
;
*A: Time range To set the time range to 30 minutes (in the 24-hour system), enter 0. BC: Starting time (hour = 00 to 23)
Example
Key operation
Print
2619 . 107 ;
Note
To perform this setting, an hourly Z report (# 160) must be printed in advance.
Programming of power saving mode
Procedure
2689
PGM 2
2689
.
* ABCD
;
Selection: Enable Disable Entry: 0 1 1 through 254 (min. ) (999: the power save mode is inhibited. )
*
Item: A BCD
Entering power save mode when time is displayed. Time (min. ) to entering power save mode since no operation is made.
Example
Key operation
Print
2689 . 0030 ;
78
FOR THE MANAGER-2-A410/A420
02. 4. 20 6:49 PM
Page 79
Functional programming for the printer
Procedure
To program zero 2990
PGM 2
2990
.
* AB
;
*AB: Printing density (00 99) 00 = 80% for standard density 50 = 90% for standard density 99 = 100% for standard density
Example
Key operation
Print
2990 . 50 ;
Programming for EURO change job
Functional programming
Procedure
To program zero 2681
PGM 2
2681
2682
2683
.
* ABC
;
Selection: Yes No Compulsory Non-compulsory Raising to unit Round off (4 - down, 5 - up) Entry: 0 1 0 1 0 1
*
Item: A Automatic conversion of unit prices into EURO B C The EURO change job at programmed date/time (#2682, 2683) Fractional treatment of Exchange 1
Example
Key operation
Print
2681 . [. . . ] · Is the mode switch set properly at the "REG" position?· Is the paper roll properly installed?
(4) No journal paper is taken up. 1 2 3 4 5 6 7 8 9 10 11 12 13 14-21 22 23 24-26 27 28-30 31 32 33 34 Description Registration error Misoperation error Desired code is not programmed yet. Compulsory pushing the subtotal key Compulsory tendering Compulsory PBAL (Reserved) Overlapped cashier error Cashier resetting over error (Reserved) Power off (Reserved) Compulsory non-add code The cashier/clerk is not assigned. [. . . ]