User manual SHARP ER-A170

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SHARP ER-A170. We hope that this SHARP ER-A170 user guide will be useful to you.


SHARP ER-A170 : Download the complete user guide (2014 Ko)

You may also download the following manuals related to this product:

   SHARP ER-A170 (2189 ko)
   SHARP ER-A170 (2318 ko)
   SHARP ER-A170 (2318 ko)
   SHARP ER-A170 (2209 ko)

Manual abstract: user guide SHARP ER-A170

Detailed instructions for use are in the User's Guide.

[. . . ] AVISO: El tomacorriente debe estar instalado cerca del equipo y debe quedar bien accesible. VARNING: Det matande vägguttaget skall placeras nära apparaten och vara lätt atkomligt. CAUTION: For a complete electrical disconnection pull out the mains plug. VORSICHT: Zur vollständigen elektrischen Trennung vom Netz den Netzstecker ziehen. [. . . ] Zero skip in clerk report Zero skip in cashier report Zero skip in transaction report Zero skip in department report Zero skip in PLU report Zero skip in hourly report Zero skip in daily net report Selection: Yes No Yes No Yes No Yes No Yes No Yes No Yes No Entry: 0 0 1 0 1 0 1 0 1 0 1 0 1 0 1 69 FOR THE MANAGER-2-A410/A420 02. 4. 20 6:49 PM Page 70 **P: 4 * Item: A B C D E F G H Always enter 0. VAT/tax amount printing on the receipt/journal Taxable amount printing on the receipt/journal Net amount printing on the receipt/journal Always enter 0. Automatic return timing for PLU level Selection: Print Do not print Print Do not print Print Do not print By one item By one receipt Entry: 0 0 0 1 0 1 0 1 0 0 0 1 **P: 5 * Item: A B C D E F G H Always enter 0. VAT shift method PLU price shift method Available mode for PLU price shift PLU price shift mode Automatic return timing for PLU price level Selection: By cashier By shift key By shift key By cashier REG and MGR modes MGR mode only Automatic return mode Lock shift mode By one item By one receipt Entry: 0 0 0 0 1 0 1 0 1 0 1 0 1 **P: 6 * Item: A B C D E F G H VAT/tax amount printing on the slip Taxable amount printing on the slip Net amount printing on the slip Time printing on the slip Always enter 0. Always enter 0. Selection: Print Do not print Print Do not print Print Do not print Print Do not print Entry: 0 1 0 1 0 1 0 1 0 0 0 0 70 FOR THE MANAGER-2-A410/A420 02. 4. 20 6:49 PM Page 71 **P: 7 * Item: A B C D E F G H Always enter 0. No sale in REG mode Finalization when the subtotal amount is zero in the REG mode Always enter 0. Always enter 0. Selection: Enable Disable Enable Disable Entry: 0 0 0 1 0 1 0 0 0 0 **P: 8 (ABCDEFGH: Always enter 0. ) **P: 9 * Item: A Always enter 0. B Exchange 1 calculation method (for EURO settings) C D E F G H Cheque/credit operation for exchange 1 Printing of the exchange 1 total amount and change amount on the receipt/journal Printing of the exchange 1 total amount at the total (payment) validation printing Always enter 0. Footer graphic logo printing Selection: Multiplication Division No Yes No Yes No Yes No Yes Entry: 0 0 1 0 1 0 1 0 1 0 0 0 1 Note The items B and D are automatically set by the operation of job #800 in the X2/Z2 mode. **P: 10 to 12 (ABCDEFGH: Always enter 0. ) **P: 13 * Item: A B C D E F G H Credit counting when RA/PO entry is finalized with the credit key Separator line in the report Link PLU printing format Always enter 0. Always enter 0. Selection: No Yes 1 line space Separator line Master PLU with total amount Each PLU Entry: 0 1 0 1 0 1 0 0 0 0 0 71 FOR THE MANAGER-2-A410/A420 02. 4. 20 6:49 PM Page 72 Programming alarm length of time with drawer opening Procedure To disable the alarm function 2617 PGM 2 2617 If the drawer still remains open when a specified length of time has elapsed, your machine gives the alarm. . Time 1 to 255 seconds ; Print Example Key operation 2617 . 30 ; Note Your machine starts to monitor how long the drawer is kept open the moment the drawer is opened at the end of a transaction in the REG/VOID mode. Up to 21 characters can be programmed per line. Procedure To keep the current setting 2646 . No. 1 NAME1 : ; 76 FOR THE MANAGER-2-A410/A420 02. 4. 20 6:49 PM Page 77 Selection of X1/Z1 and X2/Z2 reports to be printed in the stacked report sequence PGM 2 2620 Your register is equipped with the stacked report printing function that enables multiple X/Z reports to be printed in sequence with only a single request. Procedure 2620 . * 1 Job no. To cancel the stacked report sequence For full reporting (non-range report) For individual reporting * 2 Start range parameter * 2 End range parameter : ; To program for another Job no. Note · Maximum 70 steps are programmable. "1 step" means the memory size used for one no-range type job no. · When Z of stacked report is initiated, X only reports will be skipped. Job code numbers to be used are as follows. *1: Job no. 00 10 13 20 24 27 29 30 31 32 40 50 60 70 80 82 Report name General Full department Full department group PLU PLU stock PLU zero sales PLU price category Transaction Total in drawer Commission sales Full clerk Full cashier Hourly sales information Daily net report PBLU report Balance report *2: Start/End range parameter Note *3 Start PLU code/End PLU code (1 through 999999) *3 Start PLU code/End PLU code (1 through 999999) *3 Start price amount/End price amount *3 Start time/End time (0 through 2330) Range report is available only in the X1 mode. *3 Start PLU code/End PLU code (1 through 9999) *3: Both range setting and full setting are allowed. Example Key operation Print 2620 . 10 : 13 : ; 77 FOR THE MANAGER-2-A410/A420 02. 4. 20 6:49 PM Page 78 Setting the time range for hourly reports You can set the time range for an hourly report. PGM 2 2619 Procedure When A through C are all zeros 2619 . * ABC ; *A: Time range To set the time range to 30 minutes (in the 24-hour system), enter 0. BC: Starting time (hour = 00 to 23) Example Key operation Print 2619 . 107 ; Note To perform this setting, an hourly Z report (# 160) must be printed in advance. Programming of power saving mode Procedure 2689 PGM 2 2689 . * ABCD ; Selection: Enable Disable Entry: 0 1 1 through 254 (min. ) (999: the power save mode is inhibited. ) * Item: A BCD Entering power save mode when time is displayed. Time (min. ) to entering power save mode since no operation is made. Example Key operation Print 2689 . 0030 ; 78 FOR THE MANAGER-2-A410/A420 02. 4. 20 6:49 PM Page 79 Functional programming for the printer Procedure To program zero 2990 PGM 2 2990 . * AB ; *AB: Printing density (00 ­ 99) 00 = 80% for standard density 50 = 90% for standard density 99 = 100% for standard density Example Key operation Print 2990 . 50 ; Programming for EURO change job Functional programming Procedure To program zero 2681 PGM 2 2681 2682 2683 . * ABC ; Selection: Yes No Compulsory Non-compulsory Raising to unit Round off (4 - down, 5 - up) Entry: 0 1 0 1 0 1 * Item: A Automatic conversion of unit prices into EURO B C The EURO change job at programmed date/time (#2682, 2683) Fractional treatment of Exchange 1 Example Key operation Print 2681 . [. . . ] · Is the mode switch set properly at the "REG" position?· Is the paper roll properly installed? (4) No journal paper is taken up. 1 2 3 4 5 6 7 8 9 10 11 12 13 14-21 22 23 24-26 27 28-30 31 32 33 34 Description Registration error Misoperation error Desired code is not programmed yet. Compulsory pushing the subtotal key Compulsory tendering Compulsory PBAL (Reserved) Overlapped cashier error Cashier resetting over error (Reserved) Power off (Reserved) Compulsory non-add code The cashier/clerk is not assigned. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP ER-A170




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP ER-A170 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.