User manual SHARP AL-1457D

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SHARP AL-1457D. We hope that this SHARP AL-1457D user guide will be useful to you.


SHARP AL-1457D : Download the complete user guide (3114 Ko)

You may also download the following manuals related to this product:

   SHARP AL-1457D (5110 ko)
   SHARP AL-1457D (5018 ko)
   SHARP AL-1457D (4132 ko)
   SHARP AL-1457D (5110 ko)
   SHARP AL-1457D (1977 ko)
   SHARP AL-1457D (7632 ko)
   SHARP AL-1457D (36519 ko)

Manual abstract: user guide SHARP AL-1457D

Detailed instructions for use are in the User's Guide.

[. . . ] AL-1217D AL-1457D AL-1555 DIGITAL MULTIFUNCTIONAL SYSTEM OPERATION MANUAL CLASS 1 LASER PRODUCT LASER KLASSE 1 LUKOAN 1 LASERLAITE KLASS 1 LASERAPPARAT VAROITUS!LAITTEEN KÄYTTÄMINEN MUULLA KUIN TÄSSÄ KÄYTTÖOHJEESSA MAINITULLA TAVALLA SAATTAA ALTISTAA KÄYTTÄJÄN TURVALLISUUSLUOKAN 1 YLITTÄVÄLLE NÄKYMÄTTÖMÄLLE LASERSÄTEILYLLE. VARNING OM APPARATEN ANVÄNDS PÅ ANNAT SÄTT ÄN I DENNA BRUKSANVISNING SPECIFICERATS, KAN ANVÄNDAREN UTSÄTTAS FÖR OSYNLIG LASERSTRÅLNING, SOM ÖVERSKRIDER GRÄNSEN FÖR LASERKLASS 1. Laserstrahl LASERSTRÅLING CAUTION INVISIBLE LASER RADIATION WHEN OPEN AND INTERLOCKS DEFEATED. ADVERSEL USYNLIGEKSPONERING FORNÅR DEKSEL ÅPNES OG SIKKERHEDSLÅS BRYTES. [. . . ] This feature improves workflow, reduces operation noise from the copier, and provides higher reliability by reducing wear and tear on the scanning mechanism. If the unit does not function properly during use, or if a function cannot be used, see "TROUBLESHOOTING THE UNIT" (p. 61). COPY FLOW 1 Make sure that paper has been loaded in the paper tray (p. 15) or multi-bypass tray (p. 17), and check the paper size (p. 14). If paper is not loaded, see page 15. If you are using the single bypass, check the paper size and then proceed to the next step without loading paper. 2 Place the original. If you are using the original table, see "Using the original table" (p. 47). When copying onto paper larger than A4, pull out the paper output tray extension. 3 Select the copy settings. If you wish to copy using the initial settings (p. 13), proceed to the next step. (AL-1457D, AL-1555) To print on both sides of the paper, see page 52. 4 Start copying. Press the start ( ) key. If you are using the single bypass Do not press the start ( ) key. (Page 18) Multiple copies are not possible using the single bypass. 46 Do not insert paper in the single bypass when a copy job from the paper tray is in progress. · If you start a print job while a copy job is in progress, the print job will begin when the copy job is completed. · The scanning function cannot be used while a copy job is in progress. About interrupt copying If you press the start ( ) key to begin a copy job while a print job using the paper tray or multi-bypass tray is in progress, the copy job will begin automatically after the print data in the unit's memory is printed (interrupt copying). When this is done, the print data remaining in the computer is not sent to the unit. When the copy job ends, press the clear ( ) key twice, or press the ON LINE key once to change the unit to the online state (p. 32), or wait until the set auto clear time (p. 55) elapses. The remaining print data will be sent to the unit and printing will resume. Interrupt copying is not possible during a print job using the single bypass. ORIGINAL PLACEMENT Using the original table · The original table can read up to A4 original. · Image loss 4mm can occur at the leading and trailing edges of the copies. Also image loss 4. 5mm in total can occur along the other edges of the copies. It can be 6 mm (max. ) at the trailing edge of the second copy of two-sided copying. · When copying a book or an original which has been folded or a crumpled original, press down the original cover lightly. If the original cover is not securely closed, the copies may be striped or blurred. · The original cover can be simply lifted straight up and reattached to allow copying of a large original (AL-1217D) 5 1 2 Open the original cover/SPF/RSPF, and place the original. Gently close the original cover/SPF/RSPF. Original scale mark 47 Setting a large original (AL-1217D) The original cover can be removed to allow copying of bulky objects. 1 Simply lift the original cover straight up. 2 To reattach the original cover, reverse the above procedure. Using the SPF/RSPF The SPF is designed to hold up to 30 originals measuring from A5 to A4 and weighting from 52g/m2 to 90g/m2. · Before feeding originals in the original feeder tray, be sure to remove any staples or paper clips from them. · Before placing curled or wavy originals into the original feeder tray, be sure to flatten them. · The SPF/RSPF ( ) indicator on the operation panel will light up. [. . . ] Other Protective Equipment : Use of a dust mask and goggles are recommended when handling a large quantity of toner or during long term exposure, as with any non-toxic dust. MATERIAL SAFETY DATA SHEET Page: 3/4 Date Revised: Jul. F-30831 9. PHYSICAL AND CHEMICAL PROPERTIES Appearance Physical State : Solid Form : Powder Color : Black Ph : Not applicable Boiling / Melting Point : Not applicable Flash Point(°C) : Not applicable lgnition Point(°C ) : No data Explosion Properties : No data Density(g/cm³) : 5. 4 (bulk density : 2. 09) Solubility in Water : Negligible Odor : odorless 10. STABILITY AND REACTIVITY Stability Hazardous Reactions Conditions to Avoid Materials to Avoid Hazardous Decomposition Products Further Information : Stable : Dust explosion, like most finely divided organic powders. : Oxidizing Materials : CO, CO2 and NOX : None 11. TOXICOLOGICAL INFORMATION Acute Toxicity Ingestion(oral) : LD50 > 2000mg/kg (Rats) Inhalation : No data Dermal : LD50>2000mg/kg(Rats) Eye irritation : Not an irritant (Rabbits) Skin irritation : Not an irritant (Rabbits) Skin sensitizer : No sensitization Mutagenicity : Negative (Ames Test) Carcinogenicity : In 1996 the IARC reevaluated carbon black as a Group 2B carcinogen (possible human carcinogen). This classification is given to chemicals for which there is inadequate human evidence, but sufficient animal evidence on which to base an opinion of carcinogenicity. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP AL-1457D




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP AL-1457D will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.