User manual SHARP AL-1217/1457

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SHARP AL-1217/1457. We hope that this SHARP AL-1217/1457 user guide will be useful to you.


SHARP AL-1217/1457 : Download the complete user guide (2300 Ko)

Manual abstract: user guide SHARP AL-1217/1457

Detailed instructions for use are in the User's Guide.

[. . . ] AL-1217 AL-1457 DIGITAL MULTIFUNCTIONAL SYSTEM OPERATION MANUAL CLASS 1 LASER PRODUCT LASER KLASSE 1 LUKOAN 1 LASERLAITE KLASS 1 LASERAPPARAT VAROITUS!LAITTEEN KÄYTTÄMINEN MUULLA KUIN TÄSSÄ KÄYTTÖOHJEESSA MAINITULLA TAVALLA SAATTAA ALTISTAA KÄYTTÄJÄN TURVALLISUUSLUOKAN 1 YLITTÄVÄLLE NÄKYMÄTTÖMÄLLE LASERSÄTEILYLLE. VARNING OM APPARATEN ANVÄNDS PÅ ANNAT SÄTT ÄN I DENNA BRUKSANVISNING SPECIFICERATS, KAN ANVÄNDAREN UTSÄTTAS FÖR OSYNLIG LASERSTRÅLNING, SOM ÖVERSKRIDER GRÄNSEN FÖR LASERKLASS 1. Laserstrahl LASERSTRÅLING CAUTION INVISIBLE LASER RADIATION WHEN OPEN AND INTERLOCKS DEFEATED. ADVERSEL USYNLIGEKSPONERING FORNÅR DEKSEL ÅPNES OG SIKKERHEDSLÅS BRYTES. [. . . ] (p. 22) Connecting the USB interface cable 1 2 Obtain a shielded USB interface cable. Insert the cable into the USB interface connector located on the rear of the unit. 4 3 Insert the other end of the cable into the interface connector of your computer, or the USB hub connected to your computer. Connecting the parallel interface cable 1 2 3 Obtain an IEEE1284 shielded parallel interface cable. Insert the cable into the parallel interface connector located on the rear of the unit, and fasten with clasps. 4 Insert the other end of the cable into the interface connector of your computer. 45 5 MAKING COPIES This chapter explains basic and other copying functions. This memory allows the unit to scan an original once only and make up to 99 copies. This feature improves workflow, reduces operation noise from the copier, and provides higher reliability by reducing wear and tear on the scanning mechanism. If the unit does not function properly during use, or if a function cannot be used, see "TROUBLESHOOTING THE UNIT" (p. 59). COPY FLOW 1 Make sure that paper has been loaded in the paper tray (p. 15) or multi-bypass tray (p. 17), and check the paper size (p. 14). If paper is not loaded, see page 15. If you are using the single bypass, check the paper size and then proceed to the next step without loading paper. 2 Place the original. If you are using the original table, see "Using the original table" (p. 47). When copying onto paper larger than A4, pull out the paper output tray extension. 3 Select the copy settings. If you wish to copy using the initial settings (p. 13), proceed to the next step. (AL-1457) 4 Start copying. Press the start ( ) key. If you are using the single bypass Do not press the start ( ) key. (Page 18) Multiple copies are not possible using the single bypass. 46 Do not insert paper in the single bypass when a copy job from the paper tray is in progress. · If you start a print job while a copy job is in progress, the print job will begin when the copy job is completed. · The scanning function cannot be used while a copy job is in progress. About interrupt copying If you press the start ( ) key to begin a copy job while a print job using the paper tray or multi-bypass tray is in progress, the copy job will begin automatically after the print data in the unit's memory is printed (interrupt copying). When this is done, the print data remaining in the computer is not sent to the unit. When the copy job ends, press the clear ( ) key twice, or press the ON LINE key once to change the unit to the online state (p. 32), or wait until the set auto clear time (p. 53) elapses. The remaining print data will be sent to the unit and printing will resume. Interrupt copying is not possible during a print job using the single bypass. ORIGINAL PLACEMENT Using the original table · The original table can read up to A4 original. · Image loss 4mm can occur at the leading and trailing edges of the copies. Also image loss 4. 5mm in total can occur along the other edges of the copies. · When copying a book or an original which has been folded or a crumpled original, press down the original cover lightly. If the original cover is not securely closed, the copies may be striped or blurred. 5 1 2 Open the original cover/SPF, and place the original. Gently close the original cover/SPF. Original scale mark 47 Setting a large original (AL-1217) The original cover can be removed to allow copying of bulky objects. 1 Simply lift the original cover straight up. 2 To reattach the original cover, reverse the above procedure. Using the SPF The SPF is designed to hold up to 30 originals measuring from A5 to A4 and weighting from 52g/m2 to 90g/m2. · Before feeding originals in the original feeder tray, be sure to remove any staples or paper clips from them. [. . . ] This classification is given to chemicals for which there is inadequate human evidence, but sufficient animal evidence on which to base an opinion of carcinogenicity. The classification is based upon the development of lung tumors in rats receiving chronic inhalation exposures to free carbon black at levels that induce particle overload of the lung. Studies performed in animal models other than rats did not show any association between carbon black and lung tumors. Moreover, a two-year cancer bioassay using a typical toner preparation containing carbon black demonstrated no association between toner exposure and tumor development in rats. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP AL-1217/1457




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP AL-1217/1457 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.