User manual SEIKO V182 SOLAR

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SEIKO V182 SOLAR. We hope that this SEIKO V182 SOLAR user guide will be useful to you.


SEIKO V182 SOLAR : Download the complete user guide (499 Ko)

You may also download the following manuals related to this product:

   SEIKO V182 SOLAR (2497 ko)
   SEIKO V182 SOLAR (1011 ko)
   SEIKO V182 SOLAR (309 ko)
   SEIKO V182 SOLAR (312 ko)
   SEIKO V182 SOLAR (310 ko)
   SEIKO V182 SOLAR (313 ko)

Manual abstract: user guide SEIKO V182 SOLAR

Detailed instructions for use are in the User's Guide.

[. . . ] GUIDELINEOFCHARGINGTIME/ACCURACY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 ENERGYDEPLETIONFOREWARNINGFUNCTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 NOTEONPOWERSUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] l While charging the watch, make sure the watch temperature does not exceed 50 °C. V110, V145, V181 and V182) l While charging the watch, make sure the watch temperature does not exceed 60 °C. Keep the watch exposed to the light until the second hand moves at 1-second intervals. W h e n t h e w a t c h i s c h a r g e d a f t e r i t h a s completely stopped, set the date and time before wearing the watch. 6 · See"GUIDELINEOFCHARGINGTIME/ACCURACY". English TIME/CALENDAR SETTING l Models with two/three hands 1. Push back the crown completely (in accordance with a time signal for a three-hand model. ) Hourhand Secondhand Minutehand l Models with date 1. Pull out the crown to the first click and set the previous day's date. Pull out the crown to the second click w he n the s e c on d hand i s a t the 12 o'clock position. Donotsetthedatebetween9:00p. m. and1:00a. m. Otherwise, itmaynot changeproperly. · Ifitisnecessarytosetthedateduringthattimeperiod, firstchangethetime toanytimeoutsideit, setthedateandthenresetthecorrecttime. · Thewatchissodesignedthatthedatechangesoncein24hours. Turnthe handspastthe12o'clockmarkertodeterminewhetherthewatchissetforthe A. M. orP. M. period. Ifthedatechanges, thetimeissetfortheA. M. period. Whensettingtheminutehand, firstadvanceit4to5minutesaheadofthedesired timeandthenturnitbacktotheexactminute. ItisnecessarytoadjustthedateattheendofFebruaryand30-daymonths. English English GUIDELINE OF CHARGING TIME/ACCURACY V110 Environment/Lightsource(lux) A(minutes) B(hours) C(hours) A (minutes) B(hours) C(hours) Generaloffices/Fluorescentlight(700) 30W20cm/Fluorescentlight(3000) Cloudyweather/Sunlight(10000) Fairweather/Sunlight(100000) Expected life per charge from full charge to stoppage Loss/gain (monthly rate) Operational temperature range A:Timetocharge1dayofpower B:Timerequiredforsteadyoperation C:Timerequiredforfullcharge 50 11 3 1 16 3. 5 0. 9 0. 3 5months 140 30 8 2 180 35 12 2 60 10 4 0. 5 6months 180 60 10 A(minutes) B(hours) C(hours) A (minutes) B(hours) C(hours) 50 10 3 1 11 2 0. 5 0. 2 6months 175 40 10 3 75 18 5 2 6 1. 3 0. 3 0. 2 2months 82 20 5 2. 1 V111 V145 V181/V182 English u Thewatchoperateswhilecharging electricity by converting light receivedonthedialtoelectrical energy. Itcannotproperlyoperate unlesstheremainingenergyis sufficient. Placeorstorethewatch inalocationreceivinglightetc. , to sufficientlychargeelectricity. · When the watch is stopped or the second hand starts moving at2-secondintervals(formodels withasecondhand, )chargethe watchbyexposingittolight. · The time required for charging the watch varies depending on the calibres. · It is recommended that the watchbechargedforaslongas thechargingtime"B"toassure the stable movement of the watch. Lessthan20secondswhenthewatch Lessthan15secondswhenthewatch iswornonyourwristatanormal iswornonyourwristatanormal temperaturerange(5ºCto35ºC) temperaturerange(5ºCto35ºC) -5ºCto50ºC -10ºCto60ºC Lessthan20secondswhenthewatchiswornonyourwristatanormal temperaturerange(5ºCto35ºC) -5ºCto50ºC v Theabovetableprovidesonlyageneralguideline. 10 11 English ENERGY DEPLETION FOREWARNING FUNCTION When the energy stored in the rechargeable battery is reduced to an extremely low level, the second hand starts moving at 2-second intervals instead of the normal 1-second intervals. [. . . ] 32, 768Hz(Hz=Hertz. . . Cyclespersecond) ±20secondsatnormaltemperaturerange (5°Cto35°C/41°Fto95°F) ±15secondsatnormaltemperaturerange (5°Cto35°C/41°Fto95°F) ­5°Cto50°C/23°Fto122°F ­10°Cto60°C/14°Fto140°F Stepmotor Manganesetitanium-lithiumrechargeablebattery English 2. Start Elapsedtime 30minutes haveelapsed. Note:Forsomemodels, therotatingbezelrotatesonlycounterclockwise. Instant-startfunction, energydepletionforewarning functionandoverchargingpreventionfunction ForCal. V111. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Energydepletionforewarningfunctionandovercharging preventionfunction ForCal. V110. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SEIKO V182 SOLAR




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SEIKO V182 SOLAR will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.