User manual SEGA WAVERUNNER GP DELUXE TYPE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SEGA WAVERUNNER GP. We hope that this SEGA WAVERUNNER GP user guide will be useful to you.


SEGA WAVERUNNER GP DELUXE TYPE: Download the complete user guide (2868 Ko)

You may also download the following manuals related to this product:

   SEGA WAVERUNNER GP STANDARD TYPE (1831 ko)

Manual abstract: user guide SEGA WAVERUNNER GPDELUXE TYPE

Detailed instructions for use are in the User's Guide.

[. . . ] www. seuservice. com 1st PRINTING NOV 01 OWNER'S MANUAL SEGA ENTERPRISES, INC. 999-1375 VISIT OUR WEBSITE! BEFORE USING THE PRODUCT, BE SURE TO READ THE FOLLOWING: To maintain the safety: To ensure the safe usage of the product, be sure to read the following before using the product. The following instructions are intended for the users, operators and the personnel in charge of the operation of the product. After carefully reading and sufficiently understanding the warning displays and cautions, handle the product appropriately. [. . . ] Use the Start button instead of Test button, and the View button instead of Service button. When V. adjustment or replacement has been made, be sure to perform the setting in that particular V. value setting item. VOLUME SETTING > HANDLE BAR ROLL THROTTLE LEVER EXIT SELECT WITH SERVICE BUTTON AND PRESS TEST BUTTON FIG. 3 e a VOLUME SETTING Screen www. seuservice. com 44 (1) HANDLE BAR VOLUME SETTING HANDLE BAR VOLUME SETTING MAX MIN NEUTRAL 00 00 00 (FF) (01) (80) > EXIT WITHOUT SAVE EXIT WITH SAVE SELECT WITH SERVICE BUTTON AND PRESS TEST BUTTON FIG. 3 e b HANDLE BAR VOLUME SETTING Screen SETTING PROCEDURE 1 In the V. setting menu screen, press the SERVICE Button to bring the arrow to HANDLE BAR. 2 Press the TEST Button to cause the HANDLE BAR VOLUME setting screen to appear. 3 Turn the Handlebars fully to the left/right and then release. 4 Press the SERVICE Button to bring the arrow to EXIT WITH SAVE. 5 Press the TEST Button to have the Volume Setting Menu screen return to the screen. 6 When setting other Volume values also, select the applicable select item. 7 Press the SERVICE Button to move the arrow to EXIT and press the TEST Button to return to the Game Test Menu screen. 45 www. seuservice. com (2) ROLL VOLUME SETTING ROLL VOLUME SETTING MAX MIN NEUTRAL 00 00 00 (FF) (01) (80) > EXIT WITHOUT SAVE EXIT WITH SAVE SELECT WITH SERVICE BUTTON AND PRESS TEST BUTTON FIG. 3 e c ROLL VOLUME SETTING Screen SETTING PROCEDURE 1 In the Volume Setting Menu mode, press the SERVICE Button to bring the arrow to ROLL. 2 Press the TEST Button to have the ROLL VOLUME setting screen appear on the screen. 3 Incline the Ride fully to the left/right and then cause it to be in the level position. 4 Press the SERVICE Button to bring the arrow to EXIT WITH SAVE. 5 Press the TEST Button to have the Volume Setting Menu return to the screen. 6 When setting other Volume values also, choose the applicable setting item. 7 Press the SERVICE Button to move the arrow to EXIT and press the TEST Button to return to the Game Test Menu screen. www. seuservice. com 46 (3) THROTTLE LEVER VOLUME SETTING THROTTLE LEVER VOLUME SETTING MAX MIN FF FF (3B) (00) > EXIT WITHOUT SAVE EXIT WITH SAVE SELECT WITH SERVICE BUTTON AND PRESS TEST BUTTON FIG. 3 e d THROTTLE LEVER VOLUME SETTING Screen SETTING PROCEDURE 1 In the Volume Setting Menu, press the SERVICE Button and bring the arrow to THROTTLE LEVER. 2 Press the TEST Button to have the THROTTLE VOLUME SETTING screen appear. 3 Fully grip the Throttle Lever and then release. 4 By pressing the SERVICE Button, bring the arrow to EXIT WITH SAVE. 5 Press the TEST Button to have the Volume Setting Menu return on the screen. 6 When setting other Volume values also, choose the applicable setting item. 7 Press the SERVICE Button to move the arrow to EXIT and press the TEST Button to return to the Game Test Menu screen. 47 www. seuservice. com VALVE TEST This test allows the functioning of each Air Valve, Limit SW and Volume to be checked. Performing settings while riding on the Ride is dangerous as the Ride moves. Use the Start button instead of Test button, and the View button instead of Service button. VALVE TEST > PITCH VALVE & ETR CHECK ROLL VALVE & ETR CHECK EXIT PRESS TEST BUTTON TO EXIT FIG. 3 f c LIMIT SW Arrangement www. seuservice. com 48 (1) PITCH VALVE & ETR CHECK PITCH VALVE & ETR CHECK PITCH VALVE UP VALVE ETR UP VALVE DOWN VALVE ETR DOWN VALVE PITCH ETR UP LIMIT SW DOWN LIMIT SW PITCH VOLUME DOWN ON ON ON ON F0H ON ON 46H PRESS TEST BUTTON TO EXIT FIG. 3 f b PITCH VALVE & ETR CHECK Screen TEST PROCEDURE 1 In the VALVE TEST MENU, press the SERVICE Button and bring the arrow to PITCH VALVE & ETR CHECK. 2 Press the TEST Button to have the PITCH VALVE TEST screen appear. 3 Turn the Handlebars to the right to raise the Ride. 5 Position the Handlebars in the center to stop the Ride. 6 Gripping the Throttle Lever during 3 ~ 5 above increases the air pressure and releasing the Throttle Lever decreases the air pressure. 7 During 3 ~ 6 , check the functioning of each Air Valve and Limit SW. 8 Press the TEST Button to return to the VALVE TEST Menu. 9 Choose EXIT and press the TEST Button to return to the Game Test Menu screen. 49 www. seuservice. com (2) ROLL VALVE & ETR CHECK ROLL VALVE & ETR CHECK ROLL VALVE RIGHT VALVE LEFT VALVE ROLL ETR ROLL VOLUME ON ON ON F9H 80H PRESS TEST BUTTON TO EXIT FIG. 3 f c ROLL VALVE & ETR CHECK Screen TEST PROCEDURE 1 In the VALVE TEST MENU, press the SERVICE Button and bring the arrow to ROLL VALVE & ETR CHECK. 2 Press the TEST Button to have the PITCH VALVE TEST screen appear. 3 Turn the Handlebars to the right, and the Ride is subject to the centering force from the right only. 4 Turn the Handlebars to the left, and the Ride is subject to the centering force from the left only. 5 Position the Handlebars in the center to stop the centering movement. 6 Gripping the Throttle Lever during áBÅ`áD above increases the air pressure and releasing the Throttle Lever decreases the air pressure. 7 During áBÅ`áE, check the functioning of each Air Valve. 8 Press the TEST Button to return to the VALVE TEST Menu. 9 Choose EXIT and press the TEST Button to return to the Game Test Menu screen. www. seuservice. com 50 WIRING TEST Selecting WIRING TEST allows the communication between GAME BD and DRIVE BD to be checked automatically. If the communication is satisfactorily conducted, "OK" is displayed and if any irregularity is found, "ERROR" will be displayed. WIRING TEST ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : ( f 0 ----> ( f 1 ----> ( f 2 ----> ( f 3 ----> ( f 4 ----> ( f 5 ----> ( f 6 ----> ( f 7 ----> ( f 8 ----> ( f 9 ----> ( f a ----> ( f b ----> ( f c ----> ( f d ----> ( f e ----> ( f f ----> ( 0 f ----> ( 1 f ----> ( 2 f ----> ( 3 f ----> ( 4 f ----> ( 5 f ----> ( 6 f ----> ( 7 f ----> ( 8 f ----> ( 9 f ----> ( a f ----> ( b f ----> ( c f ----> ( d f ----> ( e f ----> ( f f ----> 11111110) 11111101) 11111011) 11110111) 11101111) 11011111) 10111111) 01111111) 10111111) 11011111) 11101111) 11110111) 11111011) 11111101) 11111110) 11111111) 01111111) 10111111) 11011111) 11101111) 11110111) 11111011) 11111101) 11111110) 11111101) 11111011) 11110111) 11101111) 11011111) 10111111) 01111111) 11111111) PRESS TEST BUTTON TO EXIT FIG. [. . . ] WRG-3361 MJT-3342 MJT-3343X MJT-3344X 370-5071 000-P00316-WB 000-T00408-0B 050-H00300 DESCRIPTION STEP BASE L SIDE MAT SENSOR BRKT L SENSOR PLATE L BEAM SENSO M SCR PH W/FS BLK M3 X 16 M SCR TH BLK M4 X 8 HEX NUT M3 NOTE (D-1/2) www. seuservice. com 160 30 ASSY COINCHUTE TOWER (WRG-3500) (D-1/2) 161 www. seuservice. com 30 ASSY COINCHUTE TOWER (WRG-3500) ITEM NO. 1 2 3 4 5 6 7 8 9 101 102 103 104 105 106 107 108 201 301 302 303 304 PART NO. WRG-3550 WRG-3501 BSS-1471 BSS-1472 DP-1167 105-5171 253-5366 421-6591-01 421-7501-02 220-5237-92- ~ 220-5643-01 220-5575 220-5574 280-5009-01 280-5275-SR10 310-5029-F20 601-0460 000-P00408-W 600-6455-02 600-6972-0150 WRG-60046 WRG-60047 DESCRIPTION SW UNIT COIN CHUTE TOWER METER BRKT METER HOLE LID TNG LKG CHUTE PLATE SINGLE CASH BOX STICKER COIN METER STICKER 6. 3V 0. 15A ASSY C. C 2DR ~ MAG CNTR DC5V 6P WH MZ-674-D04 CAM LOCK MASTER W/O KEY CAM LOCK W/KEYS CORD CLAMP 21 CORD CLAMP SR10 SUMITUBE F F 20MM PLASTIC TIE BELT 100 MM M SCR PH W/FS M4 X 8 WIRE HARN C. C DOOR SINGLE WIRE HARN EARTH ID5 0150MM WH EXT SOUND VR C WH EXT COINCHUTE C NOTE (D-2/2) www. seuservice. com 162 31 SW UNIT (WRG-3550) ITEM NO. WRG-3551 421-11430 220-5179 509-5028 601-0042 310-5029-D20 601-0460 WRG-60055 WRG-60056 DESCRIPTION SW BRKT STICKER SW UNIT VOL CONT B-5K OHM SW PB 1M KNOB 22 MM SUMITUBE F D 20 MM PLASTIC TIE BELT 100 MM WH SOUND VR WH TEST & SERVICE NOTE 163 www. seuservice. com 32 ASSY HANDLE MECHA (WRG-3600) (D-1/2) www. seuservice. com 164 SCREW FASTENING TORQUE TO BE M6: 9. 8 N·m (100kgf·cm) 32 ASSY HANDLE MECHA (WRG-3600) ITEM NO. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SEGA WAVERUNNER GP




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SEGA WAVERUNNER GP will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.