Detailed instructions for use are in the User's Guide.
[. . . ] 420-6941-01 1ST PRINTING
THE HOUSE OF THE DEAD 4 SPECIAL OWNER'S MANUAL 420-6941-01
OWNER'S MANUAL
(Note: Photos show items with optional accessories attached. )
Nissay Aroma Building, 5-37-1, Kamata, Ohta-ku, Tokyo 144-8721, Japan Phone: +81-3-5480-6582 Facsimile: +81-3-5480-6584 © SEGA
IMPORTANT
· Before using this product, read this manual carefully to understand the contents herein stated. · After reading this manual, be sure to keep it near the product or in a convenient place for easy reference when necessary.
In order to manage this product, there must be fire-fighting facilities and evacuation space as prescribed by related laws and by local government ordinances in the district where the product has been installed, so that countermeasures can be taken if there is an accident, fire or earthquake. There are cases, depending on the environment or district where a structure has been installed, in which inspection by a fire station or other public institution is required. Consult with your local fire department before installing the product.
BEFORE USING THE PRODUCT, BE SURE TO READ THE FOLLOWING:
To maintain safety: To ensure the safe operation of this product, be sure to read the following before usage. [. . . ] There is danger that oil from your finger will be burnt, resulting in damage.
PHOTO 6-16a
Attach lamp cover plate. Fasten with 4 truss screws.
ASSEMBLY AND INSTALLATION
PHOTO 6-16b
Remove the DVD lid of the MAIN BD floorboard at the rear base. Remove 4 truss screws.
PHOTO 6-16c
Use the master key to unlock the DVD lid, and then remove it.
100
PHOTO 6-16d
When the DVD lid is removed, you can see DVD wire inside. Pull out this wire and connect it to the DVD DRIVE.
ASSEMBLY AND INSTALLATION
PHOTO 6-16e
PHOTO 6-16f
101
17 POWERSUPPLY, EARTHCONNECTIONANDDRAINTUBEPIPING
ASSEMBLY AND INSTALLATION
· The work must only be carried out by personnel with electrical appliance knowledge. Shocksandotherseriousaccidentsmayresultiftheworkiscarried outbyunqualifiedindividuals. Ifpersonnelarenotavailable, besuretocontact the point-of-purchase for this product or the office listed in this manual, and requestthat · Useapowersupplywithanearthleakagebreaker. Ifapowersupplywithout suchbreakerisused, therecouldbeafirewheneverleakageisproduced. · Prepareasecurelygroundedearthterminalandearthwire, andthenground theproductappropriately. Iftheproductisnotgroundedproperly, therecould beelectricshock, damagetoparts, and/orpooroperation. If left exposed, these wires couldbeeasilydamagedif, forexample, customersshouldstumbleonthem. And if they are damaged, there could be an electric shock or short circuit. Eithercoverthewires orplacethem atlocations where they will not interfere withcustomerpassage. · Forsafety, connectthepowercabletotheproductfirst. Ifcableisconnectedto thepowersupplysidefirst, therecouldbeanelectricshockorshortcircuit. · Be sure to insert the drain tube and maintain conditions for drainage as necessary. Ifadraintubeisnotused, drainagecanflowdownthesideofthe tower, resultinginelectricshock, shortcircuitorwaterleakage. · If a drainage container is used, make sure that the tube does not come out fromthecontainer. Ifthecontainerisleftwithtubecomingout, therecouldbe electricshock, shortcircuitorwaterleakage. · Donotleavethedraintubeexposed. Ifleftexposed, thistubecouldbeeasily damaged if, for example, customers should stumble on it. And if this tube is damaged, therecouldbeelectricshock, shortcircuitorleakage. Eithercover thetubeorplaceitatlocationswhereitwillnotinterferewithcustomerpassage.
Becausethecompressorcompressesaircontinuously, moistureintheaircollects atthesametime, makingitimperativetohavewaterdrainage. Draindrainage fromthecompressordirectlyintothesewagesystem.
Secure power supply cable and earth wire terminal to the breaker inside the control tower, and connect power supply and earth. In the photo shown, the control tower is installed at the left side of the door, but power cable and earth wire can be placed inside the tower from either the right or left side. Also, in the photo, earth wire coaxial cable is used, but the cable does not have to be coaxial if it satisfies the rating specified. There should be a distance of 70 mm between round terminal and outer covering of the power cable.
10
1
Remove the tower lid top from the control tower. Remove 8 screws.
ASSEMBLY AND INSTALLATION
PHOTO 6-17a
Remove breaker cover made of transparent vinyl chloride. Remove 4 screws.
PHOTO 6-17b
Pass power cable from below the corner of the control tower rear panel side to the tower interior.
PHOTO 6-17c
10
In cases where the control tower is installed on the right side of the door, the power cable can be inserted from the corner on the opposite
ASSEMBLY AND INSTALLATION
PHOTO 6-17d
Remove breaker screw and secure the terminal at the cable tip.
Between two breakers there is an earth wire fastening screw. Remove screw, and then fasten the earth wire terminal of the coaxial, single phase power cable.
PHOTO 6-17e
Use cord clamp, which comes as an accessory, to fasten perimeter (sheath) of power cable separately. Be sure to attach to the correct place, or else you may become unable to install the breaker cover.
PHOTO 6-17f
10
Attach breaker cover. Secure with 4 screws.
Turn three breakers to ON.
ASSEMBLY AND INSTALLATION
PHOTO 6-17f
10 11 1
Attach tower lid top. Secure with 8 screws.
Take the opposite side of the connected power cable and connect it to the indoor power supply switchboard. [. . . ] Connect power cord to AC unit inlet, and then insert power cord plug into "power outlet with earth terminal". If there is no "power outlet with earth terminal", be sure to always establish grounding by some means; for example, by connecting the AC unit earth terminal to the earth system with an earth wire set aside for that purpose. When using a conversion adapter sold on the market to provide power, connect the adaptor's earth wire terminal to an "earth terminal that is securely grounded".
FIG. 18-3cc <For Taiwan>
198
c
When using an earth wire set aside separately, connect one end of the earth wire to AC unit earth terminal and the opposite end to indoor earth terminal. [. . . ]