User manual SEAGATE DIAMONDMAX 4320

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SEAGATE DIAMONDMAX 4320. We hope that this SEAGATE DIAMONDMAX 4320 user guide will be useful to you.


SEAGATE DIAMONDMAX 4320 : Download the complete user guide (1186 Ko)

Manual abstract: user guide SEAGATE DIAMONDMAX 4320

Detailed instructions for use are in the User's Guide.

[. . . ] HA RD DRIVE P RO D UC T MA N UA L DiamondMaxTM 4320 91728D8, 91512D7, 91303D6 91080D5 90845D4, 90648D3 90432D2 DiamondMaxTM 4320 91728D8, 91512D7, 91303D6, 91080D5 90845D4, 90648D3, 90432D2 Part #1407 All material contained herein Copyright © 1998 Maxtor Corporation. DiamondMaxTM, DiamondMaxTM 1280, DiamondMaxTM 1750, DiamondMaxTM 2160, DiamondMaxTM 2880, DiamondMaxTM 3400, DiamondMaxTM 4320, DiamondMaxTM Plus 2500 and MaxFaxTM are trademarks of Maxtor Corporation. No Quibble® Service is a registered trademark of Maxtor Corporation. Other brands or products are trademarks or registered trademarks of their respective holders. [. . . ] The block count consists of the number of sectors to be transferred as a block. (The block count is programmed by the Set Multiple Mode command, which must be executed prior to the Read Multiple command. ) READ LONG command is limited to single sector requests. When the Read Multiple command is issued, the Sector Count register contains the number of sectors requested -- not the number of blocks or the block count. If the number of sectors is not evenly divisible by the block count, as many full blocks as possible are transferred, followed by a final, partial block transfer. This final, partial block transfer is for N sectors, where N = (sector count) modulo (block count) The Read Multiple operation will be rejected with an Aborted Command error if attempted: 1. The controller reports disk errors encountered during Read Multiple commands at the start of the block or partial block transfer. However, DRQ still sets, and the transfer occurs normally, along with the transfer of any corrupt data. Remaining block data from the following the sector in error is not valid. If the Sector Count register contains 0 when the Set Multiple Mode command is issued, Read Multiple and Write Multiple commands are disabled; no error is returned. Once the appropriate action has been taken, the controller resets BSY and generates an interrupt. At power up, or after a hardware or software reset, Read Multiple and Write Multiple commands are disabled by default. 7­3 INTERFACE COMMANDS Set Multiple Mode Enables the controller to perform Read and Write Multiple operations, and establishes the block count for these commands. Before issuing this command, the Sector Count register should be loaded with the number of sectors per block. When this command is received, the controller sets BSY and examines the Sector Count register contents. If they contain a valid and supported block count value, that value is loaded for all subsequent Read and Write Multiple commands, and execution of those commands is enabled. An invalid and unsupported block count in the register results in an Aborted Command error and disallows Read Multiple and Write Multiple commands. Write Commands Write Sector(s) Writes from 1 to 256 sectors, beginning at a sector specified in the Command Block. (A sector count of 0 requests 256 sectors. ) When the Command register is written, the drive sets the DRQ bit and waits for the host to fill the sector buffer with the data to be written. An interrupt is not generated to start the first buffer fill operation. Once the buffer is full, the drive resets DRQ, sets BSY, and begins command execution. If the drive is not already on the desired track, an implied seek is performed. The data loaded in the buffer is written to the data field of the sector, followed by the ECC bytes. Upon command completion, the Command Block registers contain the cylinder, head and sector number of the last sector written. The next time the buffer is ready to be filled during back-to-back Write Sector commands, DRQ is set and an interrupt is generated. [. . . ] SEEK COMPLETE SIGNAL A digital signal level which indicates that the positioner is not moving and is located over a cylinder or offset position. SEEK TIME The amount of time between when a step pulse or seek command is issued until the head settles onto the desired cylinder. SEQUENTIAL ACCESS The writing or reading of data in a sequential order such as reading data blocks stored one after the other on magnetic tape. SERVO BURST A momentary servo pattern used in embedded servo control systems usually positioned between sectors or at the end of a track. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SEAGATE DIAMONDMAX 4320




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SEAGATE DIAMONDMAX 4320 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.