User manual SCHOLTES TT 6134

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SCHOLTES TT 6134. We hope that this SCHOLTES TT 6134 user guide will be useful to you.


SCHOLTES TT 6134 : Download the complete user guide (1508 Ko)

Manual abstract: user guide SCHOLTES TT 6134

Detailed instructions for use are in the User's Guide.

[. . . ] As a result LPG cylinders, whether partially or completely full, must not be installed or stored in rooms or storage areas which are below ground level (cellars, etc. It is advisable to keep only the cylinder currently being used in the room, positioned so that it is not subject to heat produced by external sources (ovens, fireplaces, stoves, etc. ) which could raise the temperature of the cylinder above 50°C. The appliance must be installed by a qualified professional in compliance with the instructions provided. [. . . ] Either a rigid metal pipe with fittings in compliance with the standards in force must be used for connecting to the nipple union (threaded ½"G male fitting) situated at the rear of the appliance to the right (Fig. 6), or flexible steel pipe in compliance with the standards in force, which must not exceed 2000 mm in length. Should it be necessary to turn the fitting, the gasket (supplied with the appliance) must be replaced. Upon completion of installation, check the gas circuit, the internal connections and the taps for leaks using a soapy solution (never a flame). Also check that the connecting pipe cannot come into contact with moving parts which could damage or crush it. Make sure that the natural gas pipe is adequate for a sufficient supply to the appliance when all the burners are lit Important: A pressure regulator, in compliance with the standards in force, must be inserted when connecting to a liquid gas supply (in a cylinder). Adapting to different types of gas To adapt the hob to a different type of gas other than the default type (indicated by the label placed on the upper part of the hob or on the packaging), the burner nozzles should be replaced as follows: 7) using a 7 mm socket spanner, and replace them with nozzles for the new type of gas (see table 1 "Burner and nozzle characteristics"). After replacing the nozzles, change the hob setting using the control panel as follows: While the hob is switched off, press the power button T1. Press the buttons T2, T7 and T11 simultaneously, holding them down until a numerical value appears on the display D2. At this point, with the hob set to methane G20 20 mbar, the display shows 01; to convert the hob to operation with G30 29 mbar, press the T4 button once, so that the value 02 appears on the display D2. The hob will allow 2 adjustments to be made: 01 and 02, which correspond to G20 20 mbar and G30 29 mbar respectively. If the ­ button is pressed, the burner is ignited in its safety mode and after approximately 3 seconds begins operating at its maximum power level (power level 9) and remains there; at this point, if you continue pressing the ­ button, it is possible to decrease the power level until it reaches level 1 or the burner is switched off (level 0). SWITCHING OFF A BURNER Press the + and ­ buttons corresponding to the burner you wish to switch off simultaneously. alternatively: Press the ­ button until level 0 is reached. Alternatively: Press button T1 (all burners switch off, even if the lock function has been activated; window D1 is activated). When the hob is ON and the burners switched off, if no activity is detected on the keypad after 1 minute, a buzzer sounds and the keypad is locked (the display D1 is activated); after a further minute a buzzer sounds again and the hob switches off once and for all, with the keypad remaining locked. Nevertheless, in every operating status (off, hob on and burners off, or hob and burners on), after 1 minute of inactivity on the keypad it will become locked. After an hour of operation with no adjustments made to a particular burner, the burner will switch off. To achieve the maximum burner performance level, we recommend that only cookware with a suitable diameter for the relevant burner is used, thereby preventing the flame from leaking out from under the base of the pan (see table below). Furthermore, when a liquid begins to boil, we recommend that the flame is reduced to the lowest level possible to keep the pan contents boiling. To ensure the burners operate efficiently: All types of deep casserole dish may be used on the burners, as long as the edges of the cookware do not overlap the perimeter of the hob. The most important thing is that the base of the cookware is perfectly flat. [. . . ] ⷠThe openings used for the ventilation and dispersion of heat must never be covered. ⷠAlways make sure the knobs are in the "0" position when the appliance is not in use. ⷠWhen unplugging the appliance, always pull the plug from the mains socket; do not pull on the cable. ⷠNever perform any cleaning or maintenance work without having disconnected the appliance from the electricity mains. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SCHOLTES TT 6134




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SCHOLTES TT 6134 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.