User manual SCHOLTES PP 93 G SF

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SCHOLTES PP 93 G SF. We hope that this SCHOLTES PP 93 G SF user guide will be useful to you.


SCHOLTES PP 93 G SF : Download the complete user guide (2044 Ko)

Manual abstract: user guide SCHOLTES PP 93 G SF

Detailed instructions for use are in the User's Guide.

[. . . ] Air must be taken directly from the outside and far from sources of pollution. 2A): · It must have a total clear passage cross-section of at least 6 cm² for every kW of the appliance's rated heating capacity, with a minimum of 100 cm² (the heating capacity is indicated on the rating plate). The air inflow may also come from an adjacent room, provided the latter is not a bedroom or a room where there is a risk of fire, such as warehouses, garages, inflammable materials' warehouses, etc. Air from adjacent rooms must pass freely to the room to be ventilated through permanent air vents with cross-section at least equal to that indicated above. [. . . ] Once connection has been carried out, make sure that the flexible metal pipe does not touch any moving parts and is not compressed. Only use pipes and seals that comply with current national regulations. When the installation process is complete, check the pipe fittings for leaks using a soapy solution. Hobs equipped with a three-pole power supply cable are designed to operate with alternating current at the voltage and frequency indicated on the data plate (this is located on the lower part of the appliance). If the appliance is to be installed above a built-in electric oven, the electrical connection of the hob and the oven must be carried out separately, both for electrical safety purposes and to make extracting the oven easier. connecting the supply cable to the mains Install a standardised plug corresponding to the load indicated on the data plate. The appliance must be directly connected to the mains using an omnipolar circuit-breaker with a minimum contact opening of 3 mm installed between the appliance and the mains. The circuit-breaker must be suitable for the charge indicated and must comply with current electrical regulations (the earthing wire must not be interrupted by the circuitbreaker). The supply cable must not come into contact with surfaces with temperatures higher than 50°C. The installer must ensure that the correct electrical connection has been made and that it is compliant with safety regulations. Before connecting to the power supply, make sure that: · The socket can withstand the maximum power of the appliance, which is indicated on the data plate. If the socket is incompatible with the plug, ask an authorised technician to replace it. Once the appliance has been installed, the power supply cable and the electrical socket must be easily accessible. Adapting to different types of gas To adapt the hob to a different type of gas other than default type (indicated on the rating plate at the base of the hob or on the packaging), the burner nozzles should be replaced as follows: 1. Unscrew the nozzles using a 7 mm socket spanner, and replace them with nozzles for the new type of gas (see table 1 "Burner and nozzle characteristics"). Reassemble the parts following the above procedure in the reverse order. Once this procedure is finished, replace the old rating sticker with one indicating the new type of gas used. Remove the knob and adjust the adjustment screw, which is positioned in or next to the tap pin, until the flame is small but steady (Fig. Having adjusted the flame to the required low setting, while the burner is alight, quickly change the position of the knob from minimum to maximum and vice versa several times, checking that the flame does not go out. If the device fails to work when the burners are set to the low flame setting, increase this low flame setting using the adjusting screw. Once the adjustment has been made, replace the seals on the by-passes using sealing wax or a similar substance. Once this procedure is finished, replace the old rating sticker with one indicating the new type of gas used. [. . . ] This procedure must be performed by a qualified technician authorised by the manufacturer. It may happen that the appliance does not function properly or at all. Before calling the service centre for assistance, check if anything can be done. First, check to see that there are no interruptions in the gas and electrical supplies, and, in particular, that the gas valves for the mains are open. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SCHOLTES PP 93 G SF




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SCHOLTES PP 93 G SF will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.