User manual SANYO VCC-5984

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SANYO VCC-5984. We hope that this SANYO VCC-5984 user guide will be useful to you.


SANYO VCC-5984 : Download the complete user guide (322 Ko)

Manual abstract: user guide SANYO VCC-5984

Detailed instructions for use are in the User's Guide.

[. . . ] However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ­ Reorient or relocate the receiving antenna. ­ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ­ Consult the dealer or an experienced radio/TV technician for help. [. . . ] 2 Install the auto-iris lens. CS mount type lens Carefully align the lens mount with the camera opening, then turn the lens slowly to install it. C mount type lens To allow for flange-back adjustment, install the C-mount adaptor (option) on the lens mount, then carefully align the lens mount with the camera opening and turn the lens slowly to install it. Connect the lens plug to the lens iris output connector (LENS) on the side of the camera. When using lenses from other makers, the plug shape may not correspond to the terminal on the camera. In such a case, remove the original plug and using a soldering iron, connect the supplied lens iris plug according to the diagram. (Refer to page 9. ) 3 2 CS mount type lens 3 8 English MOUNTING THE LENS Rewiring the lens cable in the lens iris plug 1 1 Prepare the lens cable. Cut the cable at the plug, then remove approx. 8 mm of the cable sheath and strip about 2 mm from each wire. 2 Install the lens iris plug. 2 Solder the cable to the pins following the correct pin layout (refer to the table and illustrations), then close the plug cover. Pin layout 2 4 1 3 2 4 1 3 1 2 3 4 DC type lenses Brake coil (­) Brake coil (+) Drive coil (+) Drive coil (­) VIDEO type lenses +12 V DC (50 mA max. ) Not used Video output (1. 0 Vp-p, high impedance) Ground (for video signal and DC power) Flange-back adjustment 2, 3 If the pick-up surface is not correctly positioned with relation to the lens focal point, the picture will be out of focus (in particular when using auto-iris power zoom lenses, sold separately). If that is the case, adjust the flange-back position as described below. 3 ADJ. 1 LOCK 4 1 2 3 4 Using a + screwdriver, loosen the FLANGE BACK LOCK screw (M2:+). Set the zoom lens to the maximum telephoto position, set the focus using the focus ring on the lens. Set the zoom lens to the maximum wide angle position, set the focus using the FLANGE BACK ADJ. Repeat steps 2 and 3, until the image stays in focus when changing from a telephoto shot to a wide angle shot. When the setting is complete, tighten the FLANGE BACK LOCK screw. English 9 CONNECTIONS 1 (A) AC 24 V connection Push to insert the cable 3 AC 24 V 2 (Video signal connections) : VIDEO IN : VIDEO OUT ~ ~ GND Basic connection for monitoring or recording The peripheral devices (VCR, monitor, lens, etc. ), AC adaptor and cables are sold separately. 1 Make the video signal connection between the camera and the monitor or time lapse VCR. Coaxial cable type and maximum length · Cable type RG-59U (3C-2V), 250 m maximum. · Cable type RG-11U (7C-2V), 600 m maximum. CAUTION: · The RG-59U type cable should not be run through electrical conduits or through the air. · Using CCTV/Video-grade coaxial cable. 2 Use a commercially available 24 V AC adaptor. In such a case, add some lights to make sure the lighting is sufficient. If the lighting is very bright, pay attention to the light angle in order to avoid or minimize the smear phenomenon effect. · Use a manual or fixed iris lens and set the lens aperture to the shortest F stop. When the switch (1 ­ 3) is set to the up position, do not use an auto-iris lens. In such a case, change to incandescent lighting or set the switch (1 ­ 3) to the down position and use an auto-iris lens. · If conditions are outside the electronic iris operation range or more than the maximum illumination, it will cause saturation of the CCD. In that case, use a manual iris lens. Gain up setting 2 Switch 4 should normally be set to "NORM". [. . . ] This warranty shall not apply to the cabinet or cosmetic parts, batteries or routine maintenance. This warranty does not apply to uncrating, setup, installation, removal of the product for repair or reinstallation of the product after repair. This warranty does not apply to repairs or replacements necessitated by any cause beyond the control of SFC including, but not limited to, any malfunction, defect or failure caused by or resulting from unauthorized service or parts, improper maintenance, operation contrary to furnished instructions, shipping or transit accidents, modification or repair by the user, abuse, misuse, neglect, accident, incorrect power line voltage, fire, flood or other Acts of God, or normal wear and tear. The foregoing is in lieu of all other expressed warranties and SFC does not assume or authorize any party to assume for it any other obligation or liability. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SANYO VCC-5984




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SANYO VCC-5984 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.