User manual SANYO PLC-XE50 BASIC SERIAL COMMAND SPECIFICATIONS V1.00

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SANYO PLC-XE50. We hope that this SANYO PLC-XE50 user guide will be useful to you.


SANYO PLC-XE50 BASIC SERIAL COMMAND SPECIFICATIONS V1.00: Download the complete user guide (316 Ko)

Manual abstract: user guide SANYO PLC-XE50BASIC SERIAL COMMAND SPECIFICATIONS V1.00

Detailed instructions for use are in the User's Guide.

[. . . ] Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2. Serial Interface Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2. 1. Transfer Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2. 2. Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3. [. . . ] Acceptable Unacceptable [ACK] [CR] ""[CR] 6. 12. VOLUME ­ Command Command Detail Response "C0A" [CR] Volume Down This command operates the same as VOLUME - button of remote control. Acceptable Unacceptable [ACK] [CR] ""[CR] 6. 13. AUDIO MUTE ON Command Command Detail "C0B" [CR] Sound Mute ON This command works the same as "MUTE" button of the remote control for Mute ON, but does not work for Mute OFF. Acceptable Unacceptable [ACK] [CR] ""[CR] Response 6. 14. AUDIO MUTE OFF Command Command Detail "C0C" [CR] Sound Mute OFF. This command works the same as "MUTE" button of the remote control for Mute OFF, but does not work for Mute ON. Acceptable Unacceptable [ACK] [CR] ""[CR] Response 6. 15. VIDEO MUTE ON Command Command Detail "C0D"[CR] Video Mute ON. This command works the same as "NO SHOW" button of the remote control for No Show ON, but does not work for No Show OFF. Acceptable Unacceptable [ACK] [CR] ""[CR] Response 11/23 PLC-XE50 Basic Serial Command Specifications 6. 16. VIDEO MUTE OFF Command Command Detail "C0E" [CR] Video Mute OFF. This command works the same as "NO SHOW" button of remote control for No Show OFF, but does not work for No Show ON. Acceptable Unacceptable [ACK] [CR] ""[CR] Response 6. 17. Screen Normal size Command Command Detail Response "C0F" [CR] Set screen size to Regular(4:3). Acceptable Unacceptable [ACK] [CR] ""[CR] 6. 18. Screen Wide size Command Command Detail Response "C10" [CR] Set screen size to Wide (16:9). Acceptable Unacceptable [ACK] [CR] ""[CR] 6. 19. Image Standard Command Command Detail Response "C11" [CR] Set Image to Standard mode. Acceptable Unacceptable [ACK] [CR] ""[CR] 6. 20. Image Real Command Command Detail Response "C12" [CR] Set Image to Real mode. Image Cinema Command Command Detail Response "C13" [CR] Set Image to Cinema mode. Acceptable Unacceptable [ACK] [CR] ""[CR] 12/23 PLC-XE50 Basic Serial Command Specifications 6. 22. Image 1 Command Command Detail Response "C14" [CR] Set image to Image 1 mode. Acceptable Unacceptable [ACK] [CR] ""[CR] 6. 23. Image 2 Command Command Detail Response "C15" [CR] Set image to Image 2 mode. Acceptable Unacceptable [ACK] [CR] ""[CR] 6. 24. Image 3 Command Command Detail Response "C16" [CR] Set image to Image 3 mode. Acceptable Unacceptable [ACK] [CR] ""[CR] 6. 25. Image 4 Command Command Detail Response "C17" [CR] Set image to Image 4 mode. Acceptable Unacceptable [ACK] [CR] ""[CR] 6. 26. Image Blackboard(Green) Command Command Detail Response "C18" [CR] Set image to Blackboard (Green) mode. Image Dynamic Command Command Detail Response "C19" [CR] Set image to Dynamic mode. [. . . ] "88"[CR] Status : Coming back after temperature anomaly When the status moves to Standby after Cooling Down due to temperature anomaly, it returns "88" [CR]. This shows that the status turns to Standby because of abnormal temperature. When Power On is executed, the information of temperature anomaly is canceled and normal operation is executed. 21/23 PLC-XE50 Basic Serial Command Specifications 7. 3. 8. "24"[CR] Status : Processing Power Save / Cooling Down Power management function in the Setting menu works and the status goes to Power Save / Cooling Down. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SANYO PLC-XE50




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SANYO PLC-XE50 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.