User manual SANYO MCO-19AIC UV BROCHURE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SANYO MCO-19AIC UV. We hope that this SANYO MCO-19AIC UV user guide will be useful to you.


SANYO MCO-19AIC UV BROCHURE: Download the complete user guide (1179 Ko)

Manual abstract: user guide SANYO MCO-19AIC UVBROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] SterisonicTM GxP Series Cell Culture Incubators CO2 Incubators MCO-19AIC(UVH) MCO-19AIC(UV) MCO-19AIC CO2 /O2 Incubators MCO-19M(UVH) MCO-19M(UV) MCO-19M Features: · The industry's most complete cell culture solution for highly regulated applications or conventional incubation. · Safe, effective and documented two-hour in situ H2O2 decontamination for the fastest turn-around. www. sanyobiomedical. com My Life. My Choice. MCO-19AIC MCO-19AIC(UV) MCO-19AIC(UVH) MCO-19M MCO-19M(UV) MCO-19M(UVH) SterisonicTMGxP Series Cell Culture CO2 and CO2 / O2 Incubators The industry's most complete cell culture solution for highly regulated applications or conventional incubation. Now with safe, effective and documented two-hour in situ H2O2 decontamination for the fastest turn-around and maximum availability. [. . . ] A physical interlock and neutralization sequence assures total decontamination and operator safety. Sterilize: 7 min. SANYO H2O2 atomizer creates vapor which is circulated throughout chamber by interior blower. PREP: 15 min. Reposition shelves, humidity pan and plenum inside SANYO chamber. UV lamp glows for 90 minutes, reducing H2O2 to harmless water droplets. Finish. Shelves, humidity pan and plenum are returned to operating position. SterisonicTM GxP H202 Decontamination Cycle (3 Hours, total) Elapsed Time: 15 min. 30 min. 45 min. 1 2 3 4 5 6 Conventional High Heat Decontamination (24 Hours, total) PREP: 15 min. Remove interior components sensitive to high heat. Start Cycle: 90 min. Interior chamber elevates to high heat. Sterilize: 14 hours Interior chamber remains at high heat. 6 SterisonicTM GxP Series Cell Culture Incubators www. sanyobiomedical. com SterisonicTM GxP Control System · Digital alphanumeric LCD display. · Message display · Pop-up menu 1 · Visual alarm indicator · H2O2 decontamination sequence start key 2 · Menu call button · Display contrast adjustment · Positive feedback tactile input buttons · Positive feedback tactile entry and function keys 4 3 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Finish. Incubator must cool from high heat temperatures to near ambient. 7 SterisonicTM GxP Design and Technology All SANYO CO2 incubators feature patented Direct Heat and Air JacketTM temperature control for accurate, uniform temperature control and inCu saFeTM for continuous contamination control. SANYO laboratory CO2 incubators feature selected SafeCellTM UV with exclusive, patented Active Background Contamination ControlTM. Direct Heat and Air JacketTM Heating System Zone Main (Red) Base (Yellow) Front (Green) Air Jacket (White) Insulation (Gray) Location Side, top and rear walls Dominant heat source Base heater elevates the humidity reservoir to achieve 95% RH at 37°C Warms the inner glass in response to ambient conditions; eliminates condensation on glass and around the opening and promotes temperature uniformity Sealed, surrounds interior chamber with natural air convection and promotes chamber wall uniformity Promotes energy efficiency, mitigates effect of ambient temperature fluctuations on air jacket Function Energy Variable Energizes any, all or in combination of heating elements as required. Microprocessor Controller Floor Variable Outer door Variable Side, top and rear walls ­­ Side, top and rear walls, door ­­ Direct Heat and Air JacketTM Heating System The patented Direct Heat and Air JacketTM surrounds the inner walls with a natural convection airflow that converts to radiant wall heat through thermal conduction to achieve accurate, uniform and highly responsive temperature control within the chamber. · The microprocessor controller directs proportional distribution of power to independent heating sources surrounding the chamber. · Arranged in three zones, these sources include the side, top and rear walls, the chamber base and the outer door. · Each zone is controlled by the microprocessor which manages continuous feedback from the incubator chamber sensors. The patented Direct Heat and Air JacketTM heating system distributes proportional energy to the interior chamber through a natural convection air jacket surrounded by a high density insulation to protect against ambient temperature fluctuations H2O2 Decontamination The unique SterisonicTM GxP H2O2 decontamination system limits downtime to less than three hours when total chamber decontamination is desired. · All interior components and CO2 sampling loop are sterilized in situ; no need for removal and autoclaving. · Available as standard on the MCO-19AIC(UVH) and MCO-19M(UVH); optional on the MCO-19AIC(UV) and MCO-19M(UV). · Following decontamination, SANYO Active Background Contamination ControlTM fights contamination while cell culture protocols are in process. SafeCellTM UV System Sterisonic GxP Models ­UVH and ­UV include SafeCellTM UV contamination control technology based on an integrated combination of narrow bandwidth, ozone-free ultraviolet light, ceramic infrared CO2 control, inCu saFeTM copperenriched stainless steel alloy interiors and Direct Heat and Air JacketTM heating managed by a microprocessor controller. 8 SterisonicTM GxP Series Cell Culture Incubators www. sanyobiomedical. com SterisonicTM GxP Design and Technology These incubators offer the industry's most stable cell culture environment and are useful for the most critical applications where continuous contamination control is essential to cell viability. SANYO SafeCellTM UV Series CO2 incubators offer significant economic benefits by minimizing interruptions for decontamination, by improving cell culture growth and expression under stable, repeatable conditions, and by minimizing the potential for product loss. · SafeCellTM UV includes a programmable ultraviolet lamp, isolated from cell cultures, that sterilizes conditioned air and humidity reservoir water to prevent contamination without affecting cell cultures in vitro. · SafeCellTM UV inhibits the growth of mycoplasma, bacteria, molds, spores, yeasts and fungi without costly HEPA filter air scrubbers which accumulate contaminants in the chamber air. · High temperature decontamination systems, which can actually encourage in vitro growth of heat resistant thermophilic and hyperthermophilic microorganisms, are avoided. · inCu saFeTM interior surfaces provide natural resistance to contamination. · The SafeCellTM UV lamp reduces H2O2 to trace sterile water condensate following the seven-minute vapor decontamination process. · The ceramic-based technique is impervious to changes in temperature and relative humidity, highly stable during door openings, and sensitive to restoration of setpoint equilibrium when the door is closed. · The sensor maintains a continuous auto-zero function for accuracy. · A CO2 sample port mounted on the incubator front permits convenient confirmation of chamber CO2 density. · An optional automatic CO2 switchover system is available; see Accessories. A two-stage regulator from the supply cylinder to the incubator is required; see Accessories. [. . . ] MTR-480 with RS232/RS485 data ports available Cabinet Design and Construction Interior, Shelves Inner Door Insulation Outer Door Access Port Leveling Feet 3, Copper-enriched stainless steel. 4 separate, gasketed inner doors, tempered glass Rigid foam polyurethane. Single opening with interior and exterior 1. 18" (30 mm) non-VOC silicone stoppers. 4, adjustable. 13 SterisonicTM GxP CO2 Series Accessories SANYO Biomedical products include a broad range of accessories to meet specific application requirements. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SANYO MCO-19AIC UV




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SANYO MCO-19AIC UV will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.