User manual SANYO MCO-19AIC BROCHURE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SANYO MCO-19AIC. We hope that this SANYO MCO-19AIC user guide will be useful to you.


SANYO MCO-19AIC BROCHURE: Download the complete user guide (947 Ko)

You may also download the following manuals related to this product:

   SANYO MCO-19AIC APPLICATION GUIDE (164 ko)
   SANYO MCO-19AIC ANNEXE 729 BROCHURE (1179 ko)

Manual abstract: user guide SANYO MCO-19AICBROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] An optional PC interface permits remote transmission for GMP/GLP protocols as required. · Precise PID logic controls and adjusts to all temperature and CO2 setpoints and alarm parameters. Cabinet Design · High volume, low profile cabinets are stackable with field-reversible doors. · Interior components and adjustable shelves are configured for easy access. Interior components and adjustable shelves are configured for easy access, in situ sterilization and flexible arrangement for a variety of applications. Model MCO-19AIC(UVH) is designed for use with a variety of standard cell culture vessels and protocols. Four adjustable shelves are included, standard; maximum shelf capacity is 15 shelves. 2 H2O2 Sterilization Hydrogen Peroxide Vapor Sterilization The use of H2O2 sterilization in biological safety cabinets and barrier isolators is a popular alternative to ethylene oxide (EtO) as a safer, more efficient decontamination method. [. . . ] Cycle Complete: When the cycle is complete the door lock releases automatically. The H2O2 atomizer and cable can be disconnected and removed and all interior components restored to their normal position. 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Finish. Incubator must cool from high heat temperatures to near ambient. 5 Design & Technology Dual Wavelength Infrared CO2 Control System The SANYO single beam, dual detector infrared CO2 system offers unprecedented control accuracy and stability by simultaneously measuring two wavelengths. The chamber sample and a reference is configured around a ceramic-based sensor linked to the microprocessor controller with a sophisticated P . I. D. /RTM (proportional, integral and derivative) algorithm. Benefits include ultra-fast recovery without overshoot and accurate CO2 averages during periods of frequent incubator access with multiple door openings. · The ceramic-based technique is impervious to changes in temperature and relative humidity, highly stable during door openings, and sensitive to restoration of setpoint equilibrium when the door is closed. · The sensor maintains a continuous auto-zero function for accuracy. · A CO2 sample port mounted on the incubator front permits convenient confirmation of chamber CO2 density. · An optional automatic CO2 switchover system is available; see Accessories. A two-stage regulator from the supply cylinder to the incubator is required; see Accessories. SafeCellTM UV System Sterisonic GxP Models ­UVH and ­UV include SafeCellTM UV contamination control technology based on an integrated combination of narrow bandwidth, ozone-free ultraviolet light, ceramic infrared CO2 control, InCu SaFeTM copper-enriched stainless steel alloy interiors and Direct Heat and Air JacketTM heating managed by a microprocessor controller. · Trace contaminants that attach to interior surfaces are destroyed by the passive germicidal properties of the InCu SaFeTM surfaces. H2O2 Sterilization The unique SterisonicTM GxP H2O2 sterilization system limits downtime to less than three hours when total chamber sterilization is desired. · All interior components and CO2 sampling loop are sterilized in situ; no need for removal and autoclaving. · Available as standard on the MCO-19AIC(UVH); optional on the MCO-19AIC(UV). · Following sterilization, SANYO Active Background Contamination ControlTM fights contamination while cell culture protocols are in process. · When components are removed, all interior surfaces are exposed for conventional wipe down. · Large curve corners and electropolished surfaces are easy to clean. · Pass thru ports accommodate probes or instrumentation leads as required for specialized cell culture protocols. Each chamber includes a port positioned in the interior, rear wall, upper left, with dual, non-VOC silicone stoppers inside and outside the cabinet for added protection. Mycoplasma Survival Results Chart summarizes test results with four strains of mycoplasma. Results demonstrate how SANYO InCu SaFeTM copper enriched stainless steel alloy offers germicidal properties of conventional C1100 copper while maintaining both corrosion-proof and discoloration-resistant properties of conventional Type 304 stainless steel. Detailed test results are available from SANYO. InCu SaFeTM Construction for Germicidal Protection SANYO offers exclusive use of InCu SaFeTM copper-enriched stainless steel alloy interior surfaces within a technical design created to eliminate contamination sources and to mitigate the effect of airborne contaminates introduced through normal use. · Selected to provide natural germicidal protection without rust or corrosion, InCu SaFeTM expresses a natural germicidal attribute to inhibit the growth of molds, fungi, mycoplasma and bacteria. · All interior components, including the air management plenum, shelf supports, humidity pan and blower wheel assembly are easily removable without tools if required. · During the H2O2 sterilization cycle interior components can be repositioned within the chamber for in situ sterilization. SANYO InCu SaFeTM Conventional Type 304 Stainless Steel Positive Control Mycoplasma Strain Mycoplasma fermentans PG18 Mycoplasma orale CH19299 YES Mycoplasma arginini G230 Mycoplasma hominis PG21 NO YES SafeCellTM UV Mode After H2O2 Vaporization Function The UV lamp automatically cycles ON for up to 90 minutes following the seven-minute H2O2 vapor cycle, reducing the H2O2 to water droplets. These droplets automatically condense onto a naturally cooler section of the interior floor for easy wipe-up. [. . . ] (170 liters) Maximum 15/chamber, 4 supplied standard; 17" x 17" (450mm), 15. 4 lbs/7kg capacity 205 lbs (93kg) nominal 24. 4" (620 mm) 4. 5" (115 mm) 4. 9" (125 mm) 19. 3" (490 mm) 24. 8" (630 mm) 20. 6" (523 mm) 3. 1" (80 mm) 1. 9" (49 mm) 1. 3" (34 mm) 0. 8" (20 mm) 34. 6" (880 mm) 26. 2" (665 mm) 22. 8" (580 mm) 18. 4" (469 mm) 1. 7" (44 mm) Stacking Doubles Capacity in Same Footprint The SterisonicTM GxP cabinet is designed for stacking, allowing one unit to be positioned on top of another, doubling interior volume without additional floor space. · The combination of stacking and reversible doors offers the most installation options possible. · An optional roller base is recommended for stacked installations to permit mobility if required; see Accessories. 11 Specifications & Accessories Accessories (SANYO SterisonicTM GxP Series) Single Chamber Model Number Dual Chamber Model Number MCO-19AIC(UVH) MCO-38AIC(UVH) MCO-19AIC(UV) MCO-38AIC(UV) Catalog Number MCO-19AIC MCO-38AIC Optional Accessories H2O2 Sterilization Kit H2O2 Vapor Atomizer H2O2 Reagent (Formulated for SANYO SterisonicTM GxP) Automatic CO2 Cylinder Switchover System Gas Calibration System, semi-automatic one point calibration function. Built-in MCO-HP MCO-H2O2 MCO-21GC MCO-SG MCO-100L MCO-18RB MCO-47ST MCO-25ST MTR-480 MCO-420 Built-In MCO-HL MCO-HP MCO-H2O2 MCO-21GC MCO-SG MCO-100L MCO-18RB MCO-47ST MCO-25ST MTR-480 MCO-420 Built-In N/A N/A N/A MCO-21GC MCO-SG MCO-100L MCO-18RB MCO-47ST MCO-25ST MTR-480 MCO-420 MCO-19UVS SANYO Biomedical products include a broad range of accessories to meet specific applications requirements. For accessory requirements or options not listed herein, contact SANYO or your authorized SANYO sales representative. H2O2 Reagent MCO-H2O2 SANYO H2O2 solution is specially formulated for optimal use with the MCO-HP atomizer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SANYO MCO-19AIC




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SANYO MCO-19AIC will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.