User manual SANYO KMS0772

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SANYO KMS0772. We hope that this SANYO KMS0772 user guide will be useful to you.


SANYO KMS0772 : Download the complete user guide (1356 Ko)

Manual abstract: user guide SANYO KMS0772

Detailed instructions for use are in the User's Guide.

[. . . ] · INSTRUCTION MANUAL · MODE D'EMPLOI Inverter-Controlled Split System Air Conditioner Climatiseur de type séparé contrôlé par inverseur KMS0772 KMS0972 KMS1272 This air conditioner uses the new refrigerant R410A. COOL/DRY Model Save These Instructions!OI-85264180806000 © SANYO 2006 Features This air conditioner is an inverter type unit that automatically adjusts capacity as appropriate. Details on these functions are provided below; refer to these descriptions when using the air conditioner. · Microprocessor Controlled Operation The interior compartment of the remote control unit contains several features to facilitate automatic operation, easy logically displayed for easy use. [. . . ] The indoor unit should make a beeping sound to indicate that it has received the signal. Rear side Remote control unit mount Press Mounting screws 5/32 x 5/8" (4 x 16 mm) (included) · To prevent loss of the remote control unit, you can connect the remote control unit to the mount by passing a string through the remote control unit and attachment hole. When Holding the Remote Control Unit · When using the remote control unit and during air conditioner operation, the transmitter on the remote control unit should be pointed toward the receiver on the indoor unit. Make sure that there are no objects between the remote control unit and receiver which could block the signal. Set in place Hole · OI-806-11-EG 11 Operation with the Remote Control Unit 1. Operation STEP 2 STEP 3 STEP 1 STEP 4 STEP 5 NOTE Check that the circuit breaker on the power panel is turned on. Press the setting buttons as described below and change the settings as desired. For dehumidifying operation For cooling operation For fan only operation To start the air conditioner, press the ON/OFF operation button. setting buttons to change the temperature setting to the desired temperature. 60 °F min. STEP 2 STEP 3 Set the FAN SPEED selector button to the setting you want. (Refer to "Adjusting the Airflow Direction" on page 20. ) To stop the air conditioner, press the ON/OFF operation button again. 12 OI-806-12-EG Operation with the Remote Control Unit (continued) NOTE · Choose the best position in the room for the remote control unit, which also acts as the sensor for room comfort and transmits the operating instructions. Once you've found this best position, always keep the remote control unit there. This appliance has a built-in 5-minute time delay circuit to ensure reliable operation. When the operation button is pressed, the compressor will start running within three minutes. Manual fan speed Simply set the FAN SPEED selector button to the position. If you want to adjust fan speed manually during operation, just set the FAN SPEED selector button as desired. Fan Only STEP 2 STEP 1 STEP 3 If you want to circulate air without any temperature control, follow these steps: STEP 1 STEP 2 STEP 3 Press the MODE selector button to switch to the fan mode Press the ON/OFF operation button. Press the FAN SPEED selector button to select the fan speed of your choice ( , or ). . OI-806-13-EG 13 Operation with the Remote Control Unit (continued) 4. To release the night setback function, press the NIGHT SETBACK button again. In Cooling and DRY Mode: ( and ) When the night setback mode is selected, the air conditioner automatically raises the temperature setting 2 °F when 30 minutes have passed after the selection was made, and then another 2 °F after another 30 minutes have passed, regardless of the indoor temperature when night setback was selected. This function is convenient when gentle cooling is needed. 2 °F Setting temperature 2 °F Press the NIGHT SETBACK button 30 min. 30 min. Time 14 OI-806-14-EG Operation with the Remote Control Unit (continued) 5. QUIET Mode QUIET Mode is used to reduce the fan sound of the indoor unit. [. . . ] Allow the edge of the air intake grille to slide into the top of the indoor unit, and then insert it all the way inside. Press in the bottom right and left corners of the air intake grille to attach the indoor unit. Air intake grille NOTE Attach so that the round pins at the top right and left corners of the air intake grille are inserted into the grooves at the top right and left of the indoor unit. 22 OI-806-22-EG Care and Cleaning (continued) Air Clean Filter The air clean filter removes dust and dirt from the air, and reduces odors and smoke from tobacco. This air clean filter cannot remove harmful gases or vapors nor ventilate air in the room. You must open doors or windows frequently when you use gas or oil heating appliances. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SANYO KMS0772




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SANYO KMS0772 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.