User manual SANYO DVPP1EX

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SANYO DVPP1EX. We hope that this SANYO DVPP1EX user guide will be useful to you.


SANYO DVPP1EX : Download the complete user guide (3682 Ko)

Manual abstract: user guide SANYO DVPP1EX

Detailed instructions for use are in the User's Guide.

[. . . ] 189 cm (74. 5 in. ) 510 kg (1125 lbs) 519 kg (1145 lbs) with paper. Site Access: Doorways to the site should be 91centimetres (36 inches) wide, or larger. The front and rear PRINTER FRAME DOORS, SHEET TRANSPORT MODULE DOORS, and the OPERATOR CONTROL PANEL (OCP) must be removed to move the PRINTER through a 36 inch doorway. The enclosures, covers, and subassemblies for the PAPER SUPPLY MODULE, the KNIFE AND SHEET TRANSPORT MODULE, and the TAKE-UP MODULE must be removed to move the PRINTER through a 28 inch doorway. [. . . ] Floor: The system should be installed on a smooth, hard, and level floor surface. Floor pitch should not exceed 1 inch in 5 feet. Operating Environment The unit to be installed is an Insulation Catagory Type II machine and operates in a Pollution Degree 2 environment in accordance with IEC 664 ( Normal Office Environment ). Description Temperature* Specification 15. 5-26. 6°C (60-80° F) for unplumbed systems15. 5-30° C (60-86° F) for plumbed systems 15-76% 0-2000 metres (6562 feet) maximum of 325 lux ** (30. 2 foot-candles) Relative Humidity Altitude Lighting * Room temperature changes of more than 5 degrees during operation will require recalibration of the PRINTER. **Although the PRINTER and PROCESSOR operate in normal room lighting, access to a darkroom is required for loading paper into cassettes. SS2616-1 ­ 23NOV99 3 SITE SPECIFICATIONS Electrical Requirements Power Voltage Range/ Frequency*** Printer: 200-254V, 47-63Hz, 1phase, 15A Processor: 208-254V, 47-63Hz, 1phase or 3 phase**, 30A 200-254V, 47-63Hz, 1phase, 15A Power Consumption Less than 9. 12kVA. Roll-to-processor Roll-to-roll Less than 2. 4kVA. ** Phase selection must be completed by CES personnel. and Canada, amperage for the PRINTER is 16A, and the amperage for the PROCESSOR is 32A. Note To prevent processor failures caused by power fluctuations, purchase a Square-D Buck and Boost Transformer (Model #500SV43F) EK Catalog #869-7799. Within the US and Canada, the PRINTER is supplied with a 2. 4-metre (8-foot) POWER CORD. The power receptacle must be located within 1. 2 metres 30 cm (4 feet 1 foot) of the rear of the PRINTER. This power receptacle should be a dedicated line with a separate CIRCUIT BREAKER. The receptacle must accept a PLUG which conforms to NEMA N6/15 (printer plug specification). Refer to the INSTALL INSTRUCTIONS for detailed information on how to do this. Locate SCSI-2 CABLES away from any source of electrical interference (e. g. transformers, fluorescent light ballast). 6 23NOV99 ­ SS2616-1 Site Specifications Plumbing Requirements Water Supply: Adequate water supply and drainage is the customer's responsibility, and must be installed to specifications by the customer before installation of the PROCESSOR begins. A WATER SUPPLY PANEL for plumbed systems is available from Kreonite (WPS-A), and is recommended. Kodak will install flexible supply line to PROCESSOR and an electrical connection to the SOLENOID. The WATER SUPPLY PANEL should be wall-mounted within 4. 9 metres (16 feet) of the rear of the PROCESSOR. Technical support and warranty of WATER SUPPLY PANEL is the responsibility of Kreonite. Water to a plumbed system must meet the following specifications: Flow rate: 3. 8-20 liters per minute (1-5 gallons per minute) Temperature: Hot- 59 C (120 F) minimum temperature. Practically, the water temperature should be adjusted to 35C (95 F) to minimize the time necessary to bring the PROCESSOR to operating temperature. [. . . ] Waste Water: A floor drain should be located convenient to the PROCESSOR. The drain system should conform to local specifications for silver-laden bleach-fix, and stabilizer or waste water. The customer will be responsible for connection of the flexible drain TUBE to a locally approved drain system. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SANYO DVPP1EX




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SANYO DVPP1EX will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.