User manual SANYO DSR-3009

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SANYO DSR-3009. We hope that this SANYO DSR-3009 user guide will be useful to you.


SANYO DSR-3009 : Download the complete user guide (2576 Ko)

Manual abstract: user guide SANYO DSR-3009

Detailed instructions for use are in the User's Guide.

[. . . ] INSTRUCTION MANUAL Digital Video Recorder with Multiplexer Function DSR-3016 DSR-3009 DSR-3016 DSR-3009 About this manual Before installing and using this unit, please read this manual carefully. Be sure to keep it handy for later reference. PRECAUTION CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN Declaration of Conformity DSR-3016, DSR-3009 SANYO SANYO FISHER COMPANY 21605 Plummer Street, Chatsworth, California 91311 Telephone No. : (818) 998-7322 · This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. [. . . ] The normal recording area and alarm recording area together can be set to a maximum of 99% of the total space. Accordingly, if the normal recording area and the alarm recording area are set to a total of 85%, the archive area will be automatically set to 15%. For example, if the normal recording area is set to 0% and the alarm recording area is set to 99%, normal recording images will not be saved onto the hard disk. The recording capacity for each recording area should be assigned according to the requirements of the particular recording location. If an additional hard disk is added, the increased capacity will be included in the TOTAL CAPACITY display. Note: · If you change the assignment of space to each recording area of the hard disk while recording is in progress, the images which have been recorded up until that point will be erased. This is because the hard disk itself is initialized during this operation, so be very careful when making this kind of setting. If you need to change the sizes of the recording areas for some reason, make sure that you make a backup copy of the images on some other medium such as a computer. · When the MIRRORING of the HDD SET setting has been set to "ON", the TOTAL CAPACITY display of RECORDING AREA SET shows a smaller value for the hard disk capacity. 3 Use the jog dial to move the cursor to NORMAL RECORDING AREA, and then turn the shuttle dial clockwise. "80%" flashes. 4 Use the jog dial to change the setting, for example from "80%" to "50%", and then turn the shuttle dial clockwise. The cursor moves to ALARM RECORDING AREA. 5 Turn the shuttle dial clockwise. "35%" flashes. 6 Turn the jog dial to change the setting, for example from 34% to 49%, and then turn the shuttle dial clockwise. The cursor moves to AREA FULL RESET. <RECORDING AREA SET> TOTAL CAPACITY NORMAL RECORDING AREA AREA FULL RESET -> ALARM RECORDING AREA AREA FULL RESET -> ARCHIVE AREA AREA FULL RESET -> : : : : 80GB 80 % 19 % 1% 7 Turn the shuttle dial counterclockwise. The screen changes to show a "WARNING" display. This is a message to warn you that the hard disk is about to be reinitialized. 8 To reinitialize the hard disk, turn the jog dial to display "YES", and then turn the shuttle dial clockwise. The RECORDING AREA SET screen appears and the recording capacities for each area are changed. <WARNING> THIS CHANGE WILL INITIALIZE THE DISK. NO Resetting each recording area Example: Set the normal recording area to 50% and the alarm recording area to 49% MENU <RECORDING AREA SET> TOTAL CAPACITY NORMAL RECORDING AREA AREA FULL RESET -> ALARM RECORDING AREA AREA FULL RESET -> ARCHIVE AREA AREA FULL RESET -> : : : : 80GB 80 % 19 % 1% CHANGE WITH JOG. SET WITH SHUTTLE Note: If you turn the shuttle dial clockwise when "NO" is selected, the RECORDING AREA SET screen appears and the recording capacities return to their previous settings. The hard disk is not reinitialized in this case. CAUTION : WHEN THE AREA SETTING IS CHANGED, THE WHOLE AREA WILL BE INITIALIZED ! 1 Press the MENU button to select RECORD SET, and then turn the shuttle dial clockwise. The RECORD SET sub-menu appears, and the cursor moves to RECORDING AREA SET. English 51 RECORDING SETTING AREA FULL RESET setting When the normal recording area and alarm recording area of the hard disk become full, the images in the recording areas will be automatically overwritten, starting from the oldest images that have been recorded. However, you can change this setting to prevent overwriting of images when the recording areas become full, at times such as when you want to check or edit the recorded images. In this case you need to specify each time that you want images to be overwritten in each recording area. The following procedure describes the method of doing this. 5 Press the EXIT/OSD button. The display returns to the normal screen. EXIT/OSD 1 Set the OVERWRITE setting for the NORMAL RECORDING AREA or ALARM RECORDING AREA to " OFF" in the RECORDING CONDITIONS SET menu. (See page 53. ) <RECORDING CONDITIONS SET> DIGITAL SERIES RECORDING : OFF TOTAL NUMBER :1 NORMAL RECORDING AREA OVERWRITE ALARM RECORDING AREA OVERWRITE REMAINING DISK WARNING Note: For overwriting to be carried out automatically, change the OVERWRITE setting for the NORMAL RECORDING AREA or ALARM RECORDING AREA to "ON". B RECORDING CONDITIONS SET menu This describe how to make settings for recording. MENU <RECORDING CONDITIONS SET> DIGITAL SERIES RECORDING : OFF TOTAL NUMBER :1 NORMAL RECORDING AREA OVERWRITE ALARM RECORDING AREA OVERWRITE REMAINING DISK WARNING : OFF : OFF : 1% : OFF : OFF : 1% This setting can be used to display the remaining recording area of the hard disk on the screen. [. . . ] The digital video recorder will continue to receive commands until an OFF (F7) command is sent to stop. The digital video recorder sends an ACK (OA) each time it receives a command. See Table 4 - Command Table on page 71. RS485 TERMINATE ON OFF Digital video recorder RS-485 Data format Mode Character length Data transmit speed Parity Stop bit Asynchronous 8 bits 2400, 4800, 9600, 19200 bps None 1 Communication protocol A proprietary Sanyo protocol (SSP: Security Serial Protocol) is used. Contact the place of purchase for further details on obtaining a special controller. English 91 INTERFACE SPECIFICATIONS Command Table (Table 4) The following table shows all of the commands that can be processed by the digital video recorder. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SANYO DSR-3009




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SANYO DSR-3009 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.