User manual SANYO 12KHS71

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SANYO 12KHS71. We hope that this SANYO 12KHS71 user guide will be useful to you.


SANYO 12KHS71 : Download the complete user guide (1024 Ko)

Manual abstract: user guide SANYO 12KHS71

Detailed instructions for use are in the User's Guide.

[. . . ] 05-423 KHS0971-1271 12/13/05 1:23 PM Page a INSTALLATION INSTRUCTIONS ­ Inverter Split System Air Conditioner ­ COOL / DRY/ HEAT Model This air conditioner uses the new refrigerant R410A. Contents Page IMPORTANT!Additional Materials Required for Installation INSTALLATION SITE SELECTION . . . . . . . . . . . . . . . . . . . Wiring Instructions for the Outdoor Unit REFRIGERANT TUBING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Finishing the Installation AIR PURGING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] 26b 11 05-423 KHS0971-1271 12/13/05 1:23 PM Page 12 WARNING Loose wiring may cause the terminal to overheat or result in unit malfunction. Therefore, be sure all wiring is tightly connected. When connecting each power wire to the corresponding terminal, follow the instructions "How to connect wiring to the terminal" and fasten the wire securely tight with the fixing screw of the terminal plate. How to connect wiring to the terminal a) For Indoor Unit (1) Cut the wire end with a cutting pliers, then strip the insulation to expose the wire about 9/32" (7 mm). (2) Using a screwdriver, loosen the terminal screw on the terminal plate. (3) Insert the wire and tighten the terminal screw completely using a screwdriver. b) For Outdoor Unit s For solid core wiring (or F-cable) Strip 3/8" (10 mm) STRIP SIZE 9/32" (7 mm) (ACTUAL SIZE) Fig. 29 Stranded wire Ring connector (1) Cut the wire end with a cutting pliers, then strip the insulation to expose the solid wire about 15/16" (25 mm). 29) (2) Using a screwdriver, remove the terminal screw(s) on the terminal plate. (3) Using the pliers, bend the solid wire to form a loop suitable for the terminal screw. (4) Shape the loop wire properly, place it on the terminal plate and fix it securely with the removed terminal screw using a screwdriver. s For stranded wiring (1) Cut the wire end with a cutting pliers, then strip the insulation to expose the stranded wiring about 3/8" (10 mm) and tightly twist the wire ends. 30 and 31) (2) Using a screwdriver, remove the terminal screw(s) on the terminal plate. (3) Using a ring connector fastener or pliers, securely clamp each stripped wire end with a ring connector. 30) (4) Place the ring connector wire, and replace and tighten the removed terminal screw using a screwdriver. 31 Screw Screw and special washer Ring connector Ring connector Wire Terminal plate Wire Fig. 32 12 05-423 KHS0971-1271 12/13/05 1:23 PM Page 13 3-9. Mounting (1) To install the indoor unit, mount the indoor unit onto the 2 tabs on the upper part of the rear plate. (2) Hold down the air discharge outlet and press the lower part of the indoor unit until it clicks to securely fasten to the 2 tabs on the lower part of the rear plate. 33) NOTE For tubing, choose either the right or left tubing direction and follow the steps below. This work can be made easier by placing padding material (such as styrofoam) at the rear right side of the indoor unit. 34) s Right-side tubing (1) Shape the refrigerant tubing so that it can easily go into the wall hole. 35) (2) Push the wiring, refrigerant tubing, and drain hose through the hole in the wall. [. . . ] (4) When the low pressure gauge reading falls to 14. 2 to 7. 1 psi (1 to 0. 5 kg/cm2), fully close the wide tube valve stem. (5) Disconnect all gauges and hoses, and replace the valve caps as they were before. 22 Pump down means collecting all refrigerant gas in the system back into the outdoor unit without losing any of the gas. Pump down is used when the unit is to be moved or before servicing the refrigerant circuit. Pump Down Procedure Be sure to carry out pump down with the unit in cooling mode. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SANYO 12KHS71




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SANYO 12KHS71 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.