User manual SAMSUNG MIM-D00

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SAMSUNG MIM-D00. We hope that this SAMSUNG MIM-D00 user guide will be useful to you.


SAMSUNG MIM-D00 : Download the complete user guide (3527 Ko)

Manual abstract: user guide SAMSUNG MIM-D00

Detailed instructions for use are in the User's Guide.

[. . . ] USER'S MANUAL MIM-D00 ENGLISH (Data Management Server) DMS K E C DB98-29777A(4) CHINESE Safety Precautions · Before using the DMS, read carefully these instructions. · After reading the instructions, keep this user's manual in a handy and safe place. · Never attempt to install the air conditioning system or to move the DMS by yourself. WARNING o not attempt to install or repair this DMS by yourself. T Always consult authorized service personnel for repairs. hen moving, consult authorized service personnel for W disconnection and installation of the DMS. [. . . ] (Set the ERV mode only when the ERV is connected. ) When setting the remote control, operated as below. (Can use the wired/wireless remote control and the indoor unit button in each room) - OFF: Disallow the Remote Control Use. (Cannot use the wired/wireless remote control and the indoor unit button in each room) - LEVEL1: a. When turning ON by the centralized controller or DMS - Allow the remote control use. When turning OFF by the centralized controller or DMS - Disallow the remote control use. When pressing the `Set exception date' button from the , users can set up the schedule exception day. 2 E-22 3 4 Users can set one of schedule repetition or not, which are every week, every day, and one day from the drop down menu . If setting to one day, assign the same date of starting date and ending date. When pressing the `Add Event' button from the , a new event is added. When pressing the `Delete Event' button from the after selecting a check box from the , the selected event is deleted. When pressing the `Save' button from the after setting all schedule information, the schedule information is saved to the DMS. When pressing the `Cancel' button from the , turn back to the schedule list screen. If you do not set the end date, the schedule does not have period limit and the end date will not appear on the screen. Temperature unit of the DMS will be set on either Fahrenheit or Celsius depending on the temperature unit used by the indoor unit. To edit existing schedule, click `Edit' from the Schedule screen. You may edit the existing schedule in the same way as adding a new schedule. 5 6 7 Note E-23 ENGLISH When pressing the `Select indoor unit' button from the , users can select the schedule indoor unit. Using the DMS through the Web (Continued) Setting and Viewing the Power Distribution Function Function Explanation Users can set, inquire, and edit the information of power distribution section. Using the power Distribution Function 1 If clicking the `Edit' button from the , area is activated and users can set the desired section. Select one of possible settings which are 1 section, 2 sections, and 3 sections. 2 As shown in the above picture, only Section A is existed. It is from 00:00 to 24:00. E-24 3 Section A and Section B are existed in 2 Sections. When pressing the `Save' button from the after editing the border time from the area , set time is adopted. If the border time between Section A and Section B is 08:00, Section A is 00:00~08:00 and Section B starts from 08:01. 4 3 Sections are classified into Section A, Section B, and Section C. The setting method is same as 2 sections' setting method. E-25 ENGLISH Using the DMS through the Web (Continued) Setting and Viewing the Power Distribution Environment Function Explanation Users can view or edit the connection between the indoor units and assigned watt-hour meter. DMS will distribute power based on the information which has been set up from this menu. 1 Check the address and the channel on the SIM transmitter that is connected to the watt-hour meter. SIM Transmitter with the address 0~7 will be displayed as 16~23 on DMS when tracking. [. . . ] - When the actual information does not match the Tracking information on DMS, power distribution result error may occur, and abnormal Peak power management may lead to Peak occurrence. - If you do not know whether information matches or not, do not run Tracking. Run Tracking when there are no communication errors between each devices and the DMS. - Device with communication error will not be recognized on DMS therefore, monitoring, controlling and power distribution cannot be done. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SAMSUNG MIM-D00




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SAMSUNG MIM-D00 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.