User manual RYOBI W5502 SCHEMA ELECTRIC

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual RYOBI W5502. We hope that this RYOBI W5502 user guide will be useful to you.


RYOBI W5502 SCHEMA ELECTRIC: Download the complete user guide (26 Ko)

Manual abstract: user guide RYOBI W5502SCHEMA ELECTRIC

Detailed instructions for use are in the User's Guide.

[. . . ] Do not restore power until the installation is complete. This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an equipment grounding conductor and a grounding plug. Only place the plug in an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. [. . . ] ~ Do not install the machine in rooms where temperatures below freezing may occur. ~ Product failure due to improper installation is not covered under the Warranty. ~ If there is any doubt concerning installation, contact Miele's Technical Service Department. U V 1-800-999-1360 techserv@mieleusa. com 1-800-565-6435 service@miele. ca SAVE THESE INSTRUCTIONS 6 Installation Front view a Exhaust connection b Power cord with plug c Control panel d Door e Four height adjustable screw feet Stand A dryer stand, with drawer, can be purchased as an optional accessory. 7 Installation Rear a Handle for transportation (arrows) b Power cord with plug c Slot for module d Air intake e Gas connection f Exhaust connection with restriction insert 8 , WARNING : Do not remove the restriction insert in the vent opening. It may result in poor drying results, damage to the laundry and higher Carbon monoxide emissions. Exception: The restriction insert must be removed if the exhaust connection if moved to the left or right side of the dryer. Installation site , WARNING: Do not install the dryer: - outdoors - in an environment with dripping water or weather - near flammable materials - in rooms which may contain gas or other fuels - in closets with solid doors - with other fuel-burning appliances in the same closet - in a location where its door could conflict with room doors. - next to a refrigerator - under a countertop - on top of a washer. , The National Fuel Gas Code restricts installations of gas appliances in garages. They must be 18 inches off the ground and protected by a barrier from vehicles. 9 Installation site Confined space installation ^ When installed in any space with less than 122 square feet, minimum clearances around the dryer must be adhered to for proper ventilation and vents for make up air must be installed. ^ Do not install any other fuel-burning appliance in the same space as the dryer. Confined door openings Any doors limiting circulation must be louvered or otherwise ventilated. It must be equally divided within 12" (30. 5 cm) from the top and bottom of the door. Minimum installation clearance Sides: 0 " (0 cm) Top: 12" (30. 5 cm) Rear: 0" (0 cm) (as close to wall as gas connection and venting allows) Front to door: 2" (5 cm) Make sure the dryer door can open completely once installed. Minimum gas supply pressure to obtain the required gas input is: 0. 15 psi (4" WC) for natural gas 0. 29 psi (8" WC) for LP gas. Maximum gas supply pressure before the gas pressure regulator 0. 37 psi (10" WC) for natural gas 0. 46 psi (13" WC) for LP gas. or - Natural Gas and Propane Installation Code, CSA B149. 1 for Canada. 14 Gas connection Gas supply Installation material (hoses and adapters) must be provided by the installer. Gas connection distances a Flare union adapter b 1/8" NPT pressure tapping plug c Gas shut-off valve For convenience (if allowed by code), an AGA or CGA approved flexible stainless steel gas hose (accordion type) may be used between the gas shut-off valve and the dryer. This will allow the appliance to be moved from the installation site for cleaning or servicing. If there is any doubt concerning installation, contact the Miele Technical Service Department at the phone number listed on the back of this manual. This appliance must be installed with its own shut off valve on the gas supply line. An 1/8" NPT pressure tapping plug must be installed immediately upstream of the gas supply connection. This allows the gas inlet pressure to be checked. 15 Gas connection , To secure all connections use appropriate Teflon tape or a thread compound, suitable for gas connections. ^ Install a 3/8" flare union adapter, a, to the female elbow, b. Hold the elbow with a wrench. ^ At the end of the dryer's gas connection hand screw on the 3 /8" NPT elbow. Using a wrench tighten the elbow with a half turn. , DO NOT OVERTIGHTEN. ^ Secure the flexible metal gas line connector to the adapter. 16 Gas connection ^ Using two wrenches tighten the flexible gas line connection. ^ Using two wrenches tighten all connections. , DO NOT OVERTIGHTEN. ^ Connect the flare union adapter, a, to the pressure tapping plug, b, originally installed on the gas shut off valve, c. ^ Open the gas shut-off valve. ^ After connecting the appliance check all fittings for gas leaks e. g. with soapy water or an equivalent. , WARNING NEVER USE AN OPEN FLAME TO TEST FOR GAS LEAKS. 17 Ducting Exhaust ducting and connections A gap of 3/8" (10 mm) must be provided between the machine and the floor. [. . . ] This factor expresses the resistance of the bend in terms of a straight length of duct. The additional length factor is then added to the existing duct to give the effective duct length. Therefore duct diameter should be increased if longer duct lengths are required. 20 Ducting Additional duct lengths (4" (100 mm) rigid pipe only) Type of bend Radius inches Flexible metal duct ­ 3' 3" (1 m) straight ­ 45° angle ­ 90° angle Smooth metal duct ­ 3' 3" (1 m) straight ­ 45° angle ­ 90° angle Elbow 90° sharp 7' 6" 230 cm Additional duct length ft 5' 11" 4' 11" 8' 2" cm 180 150 250 10" 10" 25 25 10" 10" 25 25 3' 3" 1' 11" 2' 7" 100 60 80 Concertina bend ­ 90° angle 8" 20 2' 4" 70 Wall vent or window vent ­ with louvers ­ with flap ­ with weather hood 12' 5" 4' 11" 19' 8" 380 150 600 21 Ducting Example Rigid pipe A B C D E Total duct length Wall duct with louvered wall vent 90° bend 20" (0. 5 m) rigid pipe 90° bend left / right vent opening Duct length ft 12' 5" 2' 4" 1' 7" 2' 4" 3' 3" 18' 8" Duct length m 3. 8 m 0. 7 m 0. 5 m 0. 7 m 1. 0 m 5. 7 m The total duct length is less than 33 feet (10 m), so a duct diameter of 4" (100 mm) with adapter is sufficient. 22 Ducting Exhaust connection with a flexible exhaust hose or rigid pipe Using the adapter supplied, an exhaust hose (4" [100 mm] diameter) can be installed. Necessary materials: ­ a wall or window duct (available from Miele) ­ an exhaust hose made of approved non-flammable material , WARNING Do not remove the restriction insert in the vent opening. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE RYOBI W5502




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual RYOBI W5502 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.