User manual ROYAL SOVEREIGN RSH-1050

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ROYAL SOVEREIGN RSH-1050. We hope that this ROYAL SOVEREIGN RSH-1050 user guide will be useful to you.


ROYAL SOVEREIGN RSH-1050 : Download the complete user guide (12271 Ko)

Manual abstract: user guide ROYAL SOVEREIGN RSH-1050

Detailed instructions for use are in the User's Guide.

[. . . ] Do not attempt to laminate items that exceed total recommended material thickness. Unplug machine before moving it or when it is not in use for an extended period of time. The socket-outlet shall be installed near the equipment and shall be easily accessible. EDNord - Istedgade 37A - 9000 Aalborg - Telefon 9633 3500 -3- CHARACTERISTIC RS Roll Laminator Line is advanced laminators with time transcendental design, utilizing the latest in laminating technology. It is designed for you to set temperature and speed as necessary and have the machine remember your settings. [. . . ] For setting, pull the pressure lever out and turn the lever to following the indication 2. Open/15mm : for laminating 15mm(0. 6") thick board (RSH-1050/1650) 3. 10~13mm : for laminating 10~13mm0. 4" to 0. 5") thick board 4. LAMINATING : for laminating 32~250micron thick film INSTRUCTIONS FOR CONTROL PANEL We designed this machine standing by user's convenience. You can manipulate EDNord - Istedgade 37A - 9000 Aalborg - Telefon 9633 3500 - 12 - speed and temperature of rollers each by each by the LCD controller. And with memory function, you don't need to set machine every time you laminate. ***Terms*** LCD DISPLY BUTTON 1. LCD WINDOW 1. Initial display status. EDNord - Istedgade 37A - 9000 Aalborg - Telefon 9633 3500 - 13 - It displays you the last working condition when turned on. 2. Current temperature is higher or lower than the preset temperature. 4. Temperature 1) Shows the preset temperature 2) You can check the current temperature on the heat shoe by pressing T-Check 6. Press SPEED button then speed display mode is blinking 6 times Before blinking finish, the operator can change the speed with or 3. Each time you press the button, buzzer will ring. SPEED ***Memorizing Working condition and Using the memorized working condition*** 1) Memorize working condition EDNord - Istedgade 37A - 9000 Aalborg - Telefon 9633 3500 - 16 - 1. Operator can memorize 9 working conditions. 2. Choose working condition by pressing button after pressing and speed, press MEMOR MEMORY and button. button. 3. It is memorized if buzzer is ringing with blinking. * If you change the temperature or speed when LCD UPPER LOWER SPEED MEMORY screen is still blinking, you have to press button after changing. MEMORY 4. When you memorize another working condition, you can do above 2 and 3 operation over. 2) Use the memorized working condition. 1. Operator can choose one of 9 memorized working conditions. 3. After the blinking stops, it is set the working condition MEMORY you selected and shows the working condition on the display. ***Check current temperature on the hot rollers. *** 1. When you press T-CHECK button, the present temperature will be shown on the screen and will EDNord - Istedgade 37A - 9000 Aalborg - Telefon 9633 3500 - 17 - blink five times. 2. After this, it automatically returns to the previous state. T-CHECK ***Cold mode*** 1. You can do cold lamination with this function. 6. Everytime you press the button, buzzer is ringing 7. ST/BY mode is not working at COLD mode. SPEED MEMORY C/HOT ST/BY ***STND-BY (Saving Electricity while you are not operating for a while)*** 1. When press ST/BY button will display mode, machine on the screen and STND-BY mode is set at 80C. When machine is in EDNord - Istedgade 37A - 9000 Aalborg - Telefon 9633 3500 - 18 - condition wouldn't work. Press the it will revert to the previous working. ST/BY button and 3. In this case, press the ST/BY STOP button and turn the mode. machine to the ***Check the laminating length & How many laminated papers*** 1. When you want to return to working mode Press MEAS button again. MEAS button the present numbers of length and papers laminated will be shown on 3. Also, you can reset measure mode by pressing RESET button. (for 2 second) RESET FAN MEAS LAMINATING STEPS 1. (Emergency Switch must be turned off) EDNord - Istedgade 37A - 9000 Aalborg - Telefon 9633 3500 - 19 - 2. [. . . ] 4. After work, you should clean the resin from the rollers before beginning the next operation. 5. Please check the lubricant after long operation or you do not use for a long time. The limit tension allowed is 3mm. It's not out of order Symptom *Rollers do not operate after press RUN button in. Release STND-BY switch by EDNord - Istedgade 37A - 9000 Aalborg - Telefon 9633 3500 - 24 - 4. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROYAL SOVEREIGN RSH-1050




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ROYAL SOVEREIGN RSH-1050 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.