User manual ROSS VIDEO SYNERGY 1 MAINTENANCE GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ROSS VIDEO SYNERGY 1. We hope that this ROSS VIDEO SYNERGY 1 user guide will be useful to you.


ROSS VIDEO SYNERGY 1 MAINTENANCE GUIDE: Download the complete user guide (7778 Ko)

Manual abstract: user guide ROSS VIDEO SYNERGY 1MAINTENANCE GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] Ross Video Limited Maintenance Guide Synergy 1 / Synergy 100 Edition Synergy 1 / Synergy 100 · Maintenance Guide · · · Ross Part Number: 4216D-001 Document Issue: 1 Printing Date: March 17, 2003. Printed in Canada. The information contained in this Maintenance Guide is subject to change without notice or obligation. Copyright © 2003 Ross Video Limited. Contents of this publication may not be reproduced in any form without the written permission of Ross Video Limited. Reproduction or reverse engineering of copyrighted software is prohibited. Notice The material in this manual is furnished for informational use only. [. . . ] Navigate to Panel Diagnostics Menu 1 by pressing HOME, MORE, Setup, Panel Diagnostics. Press Pots Test to display the Pots Test Menu. Pots Test Menu 3. For the three knobs to the right of the display, select Normal. The display indicates the rate at which you are turning the knob with a numeric display and bar graph. Turning the knob will display the absolute position of the knob both numerically and graphically. The number (displayed in hexadecimal) should range from 0 (full counterclockwise) to FFF (full clockwise). If the number does not reach both limits, perform a calibration as described in the "Switcher Calibration" section. 4. Note Contact Technical Support for details on each display value, or if a problem with a knob is suspected. Fader Test The Fader Test Menu allows you to test the fader on the panel. Navigate to Panel Diagnostics Menu 1 by pressing HOME, MORE, Setup, Panel Diagnostics. Press Fader Test to display the Fader Test Menu. Fader Test Menu 8-8 · Calibration and Diagnostics Synergy 1 Maintenance Guide · Synergy 1/ Synergy 100 Edition (Iss. The position of the fader is shown both numerically (in hexadecimal) and graphically. The number should range from 000 (up) to FFF (down), and the number should be stable and jitter-free. If the number does not reach both limits, perform a calibration as described in the "Switcher Calibration" section. Note Contact Technical Support for details on each display value, or if a problem with the fader is suspected. Joystick Test The Joystick Test Menu allows you to test all three axis of the Joystick. Navigate to Panel Diagnostics Menu 1 by pressing HOME, MORE, Setup, Panel Diagnostics. Press Joystick Test to display the Joystick Test Menu. Joystick Test Menu 3. Select Normal. Move the positioner up, down, left, right, and twist in both directions. The position of the fader is displayed both numerically and graphically. The number should range from 0 (center) to 64, and the number should be stable and jitter-free. If the number does not reach these limits, perform a calibration as described in the "Switcher Calibration" section. Note Contact Technical Support for details on each display value, or if a problem with the joystick is suspected. Button Test The Button Test Menu allows you to test all pushbuttons on the switcher panel. Navigate to Panel Diagnostics Menu 1 by pressing HOME, MORE, Setup, Panel Diagnostics. Synergy 1 Maintenance Guide · Synergy 1/ Synergy 100 Edition (Iss. 1) Calibration and Diagnostics · 8-9 2. Press Button Test to display the Button Test Menu. Button Test Menu 3. To exit the menu, press both Exit buttons beneath the display. Lamp Test The Lamp Test Menu allows you to test large groups of buttons on the panel. Navigate to Panel Diagnostics Menu 1 by pressing HOME, MORE, Setup, Panel Diagnostics. Press Lamp Test to display the Lamp Test Menu. Lamp Test Menu 3. [. . . ] 2-5 timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10 video . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 T Tally connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-9 test menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-13, 8-17 TD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROSS VIDEO SYNERGY 1




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ROSS VIDEO SYNERGY 1 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.