User manual ROLAND KF-90 V1.00 MIDI IMPLEMENTATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ROLAND KF-90. We hope that this ROLAND KF-90 user guide will be useful to you.


ROLAND KF-90 V1.00 MIDI IMPLEMENTATION: Download the complete user guide (425 Ko)

You may also download the following manuals related to this product:

   ROLAND KF-90 (3941 ko)
   ROLAND KF-90 (3521 ko)
   ROLAND KF-90 (29482 ko)
   ROLAND KF-90 annexe 1 (452 ko)

Manual abstract: user guide ROLAND KF-90V1.00 MIDI IMPLEMENTATION

Detailed instructions for use are in the User's Guide.

[. . . ] DIGITAL PIANO Model: KF-90 MIDI Implementation Modulation (Controller number 1) Status BnH 2nd bytes 01H 3rd byte vvH Date: July. Receive data sChannel Voice Messages qNote off Status 8nH 9nH 2nd byte kkH kkH 3rd byte vvH 00H n = MIDI channel number: 0H-FH (ch. 1-ch. 16) vv = Modulation depth: 00H-7FH (0-127) * * Not received when Rx. MODULATION = OFF. (Initial value is ON) The resulting effect is determined by System Exclusive messages. 2nd bytes 05H 3rd byte vvH n = MIDI channel number: 0H-FH (ch. 1-ch. 16) kk = note number: 00H-7FH (0-127) vv = note off velocity: 00H-7FH (0-127) * * For Drum Parts, these messages are received when Rx. NOTE OFF = ON for each Instrument. [. . . ] 00 00 01 00-07 REVERB MACRO 00: Room 1 01: Room 2 02: Room 3 03: Hall 1 04: Hall 2 05: Plate 06: Delay 07: Panning Delay 0-7 0-7 0-127 0-127 0-127 04 Hall 2 40 01 30 40 01 31 40 01 32 40 01 33 40 01 34 40 01 35 * * 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00-07 00-07 00-7F 00-7F 00-7F REVERB CHARACTER REVERB PRE-LPF REVERB LEVEL REVERB TIME REVERB DELAY FEEDBACK 04 00 40 40 00 4 0 64 64 0 REVERB MACRO is a macro parameter that allows global setting of reverb parameters. When you select the reverb type with REVERB MACRO, each reverb parameter will be set to the most suitable value. The value of REVERB CHARACTER corresponds to the REVERB MACRO of the same number. 9 40 01 38 00 00 01 00-07 CHORUS MACRO 40 01 39 40 01 3A 40 01 3B 40 01 3C 40 01 3D 40 01 3E 40 01 3F * 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00-07 00-7F 00-7F 00-7F 00-7F 00-7F 00-7F CHORUS PRE-LPF CHORUS LEVEL CHORUS FEEDBACK CHORUS DELAY CHORUS RATE CHORUS DEPTH CHORUS SEND LEVEL TO REVERB 00: Chorus 1 01: Chorus 2 02: Chorus 3 03: Chorus 4 04: Feedback Chorus 05: Flanger 06: Short Delay 07: Short Delay (FB) 0-7 0-127 0-127 0-127 0-127 0-127 0-127 02 Chorus 3 00 40 08 50 03 13 00 0 64 8 80 3 19 0 CHORUS MACRO is a macro parameter that allows global setting of chorus parameters. When you use CHORUS MACRO to select the chorus type, each chorus parameter will be set to the most suitable value. 00 00 02 00 - 7F EFX TYPE (MSB, LSB) 00 00 - 7F 7F 00 00 Thru 40 03 00 * * Refer to "EFX Type Table" (p. When part EFX type is same to this EFX type, that part connect to EFX. 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 - 7F 00 - 7F 00 - 7F 00 - 7F 00 - 7F 00 - 7F 00 - 7F 00 - 7F 00 - 7F 00 - 7F 00 - 7F 00 - 7F 00 - 7F 00 - 7F 00 - 7F 00 - 7F 00 - 7F 00 - 7F 00 - 7F 00 - 7F EFX Parameter 1 EFX Parameter 2 EFX Parameter 3 EFX Parameter 4 EFX Parameter 5 EFX Parameter 6 EFX Parameter 7 EFX Parameter 8 EFX Parameter 9 EFX Parameter 10 EFX Parameter 11 EFX Parameter 12 EFX Parameter 13 EFX Parameter 14 EFX Parameter 15 EFX Parameter 16 EFX Parameter 17 EFX Parameter 18 EFX Parameter 19 EFX Parameter 20 40 03 03 40 03 04 40 03 05 40 03 06 40 03 07 40 03 08 40 03 09 40 03 0A 40 03 0B 40 03 0C 40 03 0D 40 03 0E 40 03 0F 40 03 10 40 03 11 40 03 12 40 03 13 40 03 14 40 03 15 40 03 16 * Each parameter will be changed by EFX type. 00 00 01 00 - 7F EFX Send Level to Reverb 40 03 17 * Set to 0 when EFX type is changed. 00 00 01 00 - 7F EFX Send Level to Chorus 40 03 18 * Set to 0 when EFX type is changed. 00 00 01 00 00 01 00 - 7F 00 - 7F EFX Depth EFX Control Source 1 Dry 100% - EFX 100% 00: OFF 01 - 5F: Control Change No. 71: CAf 72: Bender 7F 00 40 03 1A 40 03 1B 40 03 1C 40 03 1D 40 03 1E * 00 00 01 00 00 01 00 00 01 00 - 7F 00 - 7F 00 - 7F EFX Control Depth 1 EFX Control Source 2 EFX Control Depth 2 7F *Refer to EFX Control Source 1 00 7F -100% - +100% -100% - +100% Marked #1 or #2 can be controlled by EFX CONTROL SOURCE 1 or 2. qPart Parameters This instrument has 16 parts. Parameters that can be set individually for each Part are called Part parameters. If you use exclusive messages to set Part parameters, specify the address by Block number rather than Part Number (normally the same number as the MIDI channel). The Block number can be specified as one of 16 blocks, from 0 (H) to F (H). x. . . BLOCK NUMBER (0-F), Part 1 (MIDI ch = 1) x = 1 Part 2 (MIDI ch = 2) x = 2 : : : Part 9 (MIDI ch = 9) x = 9 Part10 (MIDI ch = 10) x = 0 Part11 (MIDI ch = 11) x = A Part12 (MIDI ch = 12) x = B : : : Part16 (MIDI ch = 16) x = F 10 Address (H) 40 1x 00 40 1x 01# 40 1x 02 40 1x 03 40 1x 04 40 1x 05 40 1x 06 40 1x 07 40 1x 08 40 1x 09 40 1x 0A * Size (H) 00 00 02 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 Data (H) 00-7F 00-7F 00-10 00-01 00-01 00-01 00-01 00-01 00-01 00-01 00-01 Parameter TONE NUMBER Rx. VALUE 1-128 1-16, OFF OFF/ON OFF/ON OFF/ON OFF/ON OFF/ON OFF/ON OFF/ON OFF/ON Default Value (H) Description 00 0 00 1 Same as the Part Number 01 ON 01 ON 01 ON 01 ON 01 ON 01 ON 01 ON 00 (01*) OFF (ON*) When "GM1 System On" and "GM2 System On" are received, Rx. 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00 00 01 00-01 00-01 00-01 00-01 00-01 00-01 00-01 00-01 00-01 00-02 Rx. SOFT MONO/POLY MODE (= CC# 126 01 / CC# 127 00) ASSIGN MODE OFF/ON OFF/ON OFF/ON OFF/ON OFF/ON OFF/ON OFF/ON OFF/ON Mono/Poly 0 = SINGLE 1 = LIMITED-MULTI 2 = FULL-MULTI 01 01 01 01 01 01 01 01 01 00 at x = 0 01 at x 0 ON ON ON ON ON ON ON ON Poly SINGLE at x = 0 LIMITED-MULTI at x 0 40 1x 0B 40 1x 0C 40 1x 0D 40 1x 0E 40 1x 0F 40 1x 10 40 1x 11 40 1x 12 40 1x 13 40 1x 14 * ASSIGN MODE is the parameter that determines how voice assignment will be handled when sounds overlap on identical note numbers in the same channel (i. e. , repeatedly struck notes). This is initialized to a mode suitable for each Part, so for general purposes there is no need to change this. 00 00 01 00-02 USE FOR RHYTHM PART 0 = OFF 1 = MAP1 2 = MAP2 00 at x 0 01 at x = 0 OFF at x 0 MAP1 at x 0 40 1x 15 * This parameter sets the Drum Map of the Part used as the Drum Part. This instrument can simultaneously (in different Parts) use up to two Drum Maps (MAP1, MAP2). With the initial settings, Part10 (MIDI CH = 10, x = 0) is set to MAP1 (1), and other Parts are set to normal instrumental Parts (OFF (0)). [. . . ] The values of RPN #1 (Master Fine Tuning) and System Exclusive MASTER TUNE are added together to determine the actual pitch sounded by each Part. Frequently used tuning values are given in the following table for your reference. +----------------+----------------+----------------------------+--------------------------------------+ |Hz in A4| cent | RPN #1 | Sys. Ex. 40 00 00 | +----------------+----------------+----------------------------+--------------------------------------+ | 445. 0 | +19. 56 | 4C 43 (+1603)| 00 04 0C 04 (+196)| | 444. 0 | +15. 67 | 4A 03 (+1283)| 00 04 09 0D (+157)| | 443. 0 | +11. 76 | 47 44 (+ 964)| 00 04 07 06 (+118)| | 442. 0 | + 7. 85 | 45 03 (+ 643)| 00 04 04 0F (+ 79)| | 441. 0 | + 3. 93 | 42 42 (+ 322)| 00 04 02 07 (+ 39)| | 440. 0 | 0. 00 | 40 00 ( 0)| 00 04 00 00 ( 0)| | 439. 0 | - 3. 94 | 3D 3D (- 323)| 00 03 0D 09 (- 39)| | 438. 0 | - 7. 89 | 3A 7A (- 646)| 00 03 0B 01 (- 79)| +----------------+----------------+----------------------------+--------------------------------------+ <Example> Set the tuning of MIDI channel 3 to A4 = 442. 0 Hz Send RPN#1 to MIDI channel 3. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROLAND KF-90




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ROLAND KF-90 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.