User manual ROLAND CDX-1 V1.01 MIDI IMPLEMENTATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ROLAND CDX-1. We hope that this ROLAND CDX-1 user guide will be useful to you.


ROLAND CDX-1 V1.01 MIDI IMPLEMENTATION: Download the complete user guide (73 Ko)

You may also download the following manuals related to this product:

   ROLAND CDX-1 (4954 ko)
   ROLAND CDX-1 (2974 ko)
   ROLAND CDX-1 (5075 ko)
   ROLAND CDX-1 annexe 3 (80 ko)
   ROLAND CDX-1 annexe 1 (687 ko)
   ROLAND CDX-1 annexe 2 (54 ko)
   ROLAND CDX-1 VERSION 1.5 (575 ko)
   ROLAND CDX-1 V1.5 ADDED FUNCTIONS (726 ko)
   ROLAND CDX-1 ANNEXE 935 (6780 ko)
   ROLAND CDX-1 V1.5 ADDED FUNCTIONS (726 ko)

Manual abstract: user guide ROLAND CDX-1V1.01 MIDI IMPLEMENTATION

Detailed instructions for use are in the User's Guide.

[. . . ] 16 2001 MIDI Machine Control Commands Status F0H Byte F0H 7FH Dev 06H aaH | bbH F7H * Data Bytes 7FH, Dev, 06H, aaH, . . . , bb Status F7H 1. [. . . ] Start Playing back, and Start Recording the track that status are record standby mode. s System Common Messages q MIDI Time Code Quarter Frame Messages MIDI Time Code Quarter Frame Messages can be transmitted while the CDX-1 is running (Playing or Recording) if the SONG parameter "Sync Out" is "MTC. " Status F1H nnn = Message type: Second mmH (= 0nnndddd) 0 = Frame count LS nibble 1 = Frame count MS nibble 2 = Seconds count LS nibble 3 = Seconds count MS nibble 4 = Minutes count LS nibble 5 = Minutes count MS nibble 6 = Hours count LS nibble 7 = Hours count MS nibble 0H­FH (0­15) q RECORD EXIT Status F0H Byte F0H 7FH Dev 06H 07H F7H Data Bytes Status 7FH, Dev, 06H, 07H F7H Description Status of System Exclusive Message Universal System Exclusive Message Realtime Header Device ID (10H or 7FH) MMC Command Message RECORD EXIT EOX (End of System Exclusive Message) dddd = 4 bit nibble data: If the upper and lower 4 bits of the count are combined, these bit fields are assigned as follows. Frame Count xxx yyyyy Seconds Count Status F7H xx yyyyyy Minutes Count xx yyyyyy Hours Count x yy xxxyyyyy Reserved (000) Frame No. (0­29) xxyyyyyy Reserved (00) Seconds Count (0­59) xxyyyyyy Reserved (00) Minutes Count (0­59) xyyzzzzz Reserved (0) Time Code type 0 = 24 Frames/Sec 1 = 25 Frames/Sec 2 = 30 Frames/Sec (Drop Frame) 3 = 30 Frames/Sec (Non Drop Frame Hours Count (0­23) If the device ID on the message was as same as that of the receiving 10H or 7FH, the CDX-1 exits from the record condition. q LOCATE (MCP) Format 2-LOCATE [TARGET] Status F0H Data Bytes 7FH, Dev, 06H, 44H, 06H, 01H, hrH, mnH, scH, frH, ffH Byte F0H 7FH Dev 06H 44H 06H 01H hrH, mnH, scH, frH, ffH F7H Description Status of System Exclusive Message Universal System Exclusive Message Realtime Header Device ID (10H or 7FH) MMC Command Message LOCATE (MCP) Number of Bytes "TARGET" sub command Standard Time with Sub Frame EOX (End of System Exclusive Message) zzzzz If the device ID on the message was as same as that of the receiving 10H or 7FH, the CDX-1 locates the specified time location received from the command. 2 MIDI Implementation s System Exclusive Message Status F0H Byte F0H iiH Data Bytes iiH, ddH, . . . , eeH Status F7H 4. MIDI Machine Control s MIDI Machine Control Details q STOP (MCS) Status F0H Byte F0H 7FH Dev 06H 01H F7H Data Bytes Status 7FH, Dev, 06H, 01H F7H Description Status of System Exclusive Message Universal System Exclusive Message Realtime Header Device ID MMC Command Message STOP (MCS) EOX (End of System Exclusive Message) ddH | eeH F7H Description Status of System Exclusive Message Manufacturer ID 41H RolandsManufacturerID' 7EH Universal Non Realtime Message 7FH Universal Realtime Message Data: 00H­7FH (0­127) | Data EOX (End of System Exclusive Message) q Universal System Exclusive Message INQUIRY MESSAGE Identity Reply Status F0H Data Bytes 7EH, Dev, 06H, 02H, 41H, 3BH, 01H, 00H, 00H, ssH, ssH, ssH, ssH, ssH Description Status of System Exclusive Message Universal System Exclusive Message Non Realtime Header Device ID General Information (sub-ID #1) Identify Reply (sub-ID #2) Manufacturer ID (Roland) Device Family Code (CDX-1) Device Family No. Software Revision Level EOX (End of System Exclusive Message) Status F7H If the transport switch [STOP] was pressed, the CDX-1 transmits as the device ID 7FH. q DEFERRED PLAY (MCS) Status F0H Byte F0H 7FH Dev 06H 03H F7H Data Bytes 7FH, Dev, 06H, 03H Status F7H Byte F0H 7EH Dev 06H 02H 41H 3BH, 01H 00H, 00H ssH, ssH, ssH, ssH F7H Description Status of System Exclusive Message Universal System Exclusive Message Realtime Header Device ID MMC Command Message DEFERRED PLAY (MCS) EOX (End of System Exclusive Message) If the transport switch [PLAY] was pressed, the CDX-1 transmits as the device ID 7FH. q RECORD STROBE Status F0H Byte F0H 7FH Dev 06H 06H F7H Data Bytes Status 7FH, Dev, 06H, 06H F7H Description Status of System Exclusive Message Universal System Exclusive Message Realtime Header Device ID MMC Command Message RECORD STROBE EOX (End of System Exclusive Message) The CDX-1 transmits as the device ID 10H. MIDI Time Code Status F0H Byte F0H 7FH Dev 01H 01H hr Data Bytes 7FH, Dev, 01H, 01H, hr, mn, sc, fr Status F7H mn sc fr F7H Description Status of System Exclusive Message Universal System Exclusive Message Realtime Header Device ID MIDI Time Code (sub-ID #1) Full Message (sub-ID #2) type/hours (0yyzzzzz) yy Time code type 0 = 24 frame/sec 1 = 25 frame/sec 2 = 30 frame/sec (Drop frame) 3 = 30 frame/sec (Non-drop frame) zzzzz Hours (0-23) Minutes (0-59) Seconds (0-59) Frames (0-29) EOX (End of Exclusive) If the transport switch [REC] was pressed out of the recording condition, the CDX-1 transmits as the device ID 7FH. q RECORD EXIT Status F0H Byte F0H 7FH Dev 06H 07H F7H Data Bytes Status 7FH, Dev, 06H, 07H F7H Description Status of System Exclusive Message Universal System Exclusive Message Realtime Header Device ID MMC Command Message RECORD EXIT EOX (End of System Exclusive Message) If the transport switch [REC] was pressed while recording, the CDX-1 transmits as the device ID 7FH. If the time locate is operated effectively, the CDX-1 transmits as the device ID 7FH. MIDI Machine Control Commands Status F0H Byte F0H 7FH Dev 06H aaH | bbH F7H * Data Bytes 7FH, Dev, 06H, aaH, . . . , bb Status F7H q LOCATE (MCP) Format 2-LOCATE [TARGET] Status F0H Data Bytes 7FH, Dev, 06H, 44H, 06H, 01H, hrH, mnH, scH, frH, ffH Status F7H Description Status of System Exclusive Message Universal System Exclusive Message Realtime Header Device ID MMC Command Message Command | Command EOX (End of System Exclusive Message) Byte F0H 7FH Dev 06H 44H 06H 01H hrH, mnH, scH, frH, ffH F7H Description Status of System Exclusive Message Universal System Exclusive Message Realtime Header Device ID MMC Command Message LOCATE (MCP) Number of Bytes "TARGET" sub command Standard Time with Sub Frame EOX (End of System Exclusive Message) See "4. If the time locate is operated effectively, the CDX-1 transmits as the device ID 7FH. 3 MIDI Implementation 5. [. . . ] 16, 2001 Version : 1. 01 Remarks MIDI Implementation Chart Transmitted 1­16 1­16 1­16 1­16 Recognized Basic Channel Mode Default Changed Default Messages Altered Mode 3 X ************** Mode 3 X X O 0­127 0­127 X X X X X Note Number: Velocity After Touch Pitch Bend Control Change O 0­127 True Voice Note On Note Off Key's Channel's ************** O 1­127 X9n, v = 0 X X X X X Program Change O :True Number ************** O 0­63 Pad Bank1­64 System Exclusive O O : Quarter Frame System : Song Position Common : Song Select : Tune Request System Real Time : Clock : Commands : All Sound Off : Reset All Controllers : Active Sensing : System Reset O X X X X X X X X X X X *1 X X X X X X O X X O X X Aux : Local On/Off Messages : All Notes Off Notes * 1 SyncOut=MTC Only Mode 1 : OMNI ON, POLY Mode 3 : OMNI OFF, POLY Mode 2 : OMNI ON, MONO Mode 4 : OMNI OFF, MONO O : Yes X : No 40452856 '01-4-REC 1st Edition 5 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROLAND CDX-1




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ROLAND CDX-1 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.