User manual RHEEM 90 PLUS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual RHEEM 90 PLUS. We hope that this RHEEM 90 PLUS user guide will be useful to you.


RHEEM 90 PLUS : Download the complete user guide (344 Ko)

Manual abstract: user guide RHEEM 90 PLUS

Detailed instructions for use are in the User's Guide.

[. . . ] 10 GAS FURNACES 90 PLUS® MODULATING UPFLOW GAS FURNACES WITH CONTOUR COMFORT CONTROL® The Rheem Prestige Series® 90 Plus High Efficiency line of upflow gas furnaces are designed for utility rooms, closets, or alcoves. Because of the low-profile 34 inch height, the RGFD- model can be used vertically to satisfy most applications that traditionally call for a horizontal furnace. The design is certified by CSA. RGFD- SERIES Models with Input Rates from 60, 000 to 120, 000 BTU/HR [17. 58 to 35. 16 kW] (All Models 92% A. F. U. E. [. . . ] NOTE: Furnace is not listed for use with fuels other than natural or L. P. All models can be converted by a qualified distributor or local service dealer to use L. P. (propane) gas and may be ordered as optional accessories from a parts distributor. Fossil Fuel Kits for use with Heat Pumps. 2 Rheem Manufacturing Company THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES WARNING BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER. PHYSICAL DATA AND SPECIFICATIONS--UPFLOW MODELS U. S. and Canadian Models MODEL NUMBERS INPUT­MAXIMUM (BTU/HR) [kW] HEATING CAPACITY­MAXIMUM [kW] INPUT­MINIMUM (BTU/HR) [kW] HEATING CAPACITY­MINIMUM [kW] HEATING EXT. STATIC PRESSURE [kPa] BLOWER (D X W IN. ) [mm] ECM MOTOR HP [W] UNIT AMPS MAXIMUM OVERCURRENT PROTECTION HEATING CFM­MAXIMUM [L/s] HEATING CFM­MINIMUM [L/s] COOLING CFM­RANGE [L/s] MAXIMUM EXT. STATIC PRESSURE [kPa] TEMPERATURE RISE RANGE °F [°C] MAX OUTLET AIR TEMPERATURE °F [°C] RETURN AIR CABINETS­RXGRFILTER SIZE (IN. ) [mm] BOTTOM FILTER SIZE (IN. ) [mm] SIDE APPROX. SHIPPING WEIGHT (LBS. ) [kg] AFUE RGFD-06EMCK 60, 000 [17. 58] 55, 800 [16. 35] 24, 000 [7. 03] 22, 560 [6. 61] 0. 12 [. 029] 11 x 7 [279 x 178] 1/2 [373] 8. 7 15 795 [375] 320 [151] 600-1200 [283-566] 0. 80 [0. 20] 40-70 [22. 2-38. 9] 170 [76. 7] C17B 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 127 [57. 6] 93. 4% RGFD-07EMCK 75, 000 [21. 98] 72, 000 [21. 10] 30, 000 [8. 79] 28, 200 [8. 26] 0. 12 [. 029] 11 x 7 [279 x 178] 1/2 [373] 8. 7 15 995 [470] 430 [203] 600-1200 [283-566] 0. 80 [0. 20] 40-70 [22. 2-38. 9] 180 [82. 2] C17B 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 133 [60. 3] 92. 8% RGFD-09EZCM 90, 000 [26. 38] 86, 000 [25. 20] 36, 000 [10. 55] 33, 840 [9. 92] 0. 15 [. 037] 12 x 11 [305 x 279] 1 [746] 12. 0 15 1195 [564] 515 [243] 1200-2000 [566-944] 0. 80 [0. 20] 40-70 [22. 2-38. 9] 180 [82. 2] C21B 191/4 x 25 [489 x 635] 153/4 x 25 [400 x 635] 158 [71. 7] 94. 1% RGFD-10EZCM 105, 000 [30. 77] 100, 000 [29. 31] 42, 000 [12. 31] 39, 000 [11. 57] 0. 20 [. 049] 12 x 11 [305 x 279] 1 [746] 12. 0 15 1395 [658] 600 [283] 1200-2000 [566-944] 0. 80 [0. 20] 40-70 [22. 2-38. 9] 180 [82. 2] C21B 191/4 x 25 [489 x 635] 153/4 x 25 [400 x 635] 162 [73. 5] 92. 4% RGFD-12ERCM 120, 000 [35. 17] 115, 000 [33. 70] 48, 000 [14. 07] 45, 120 [13. 22] 0. 20 [. 049] 11 x 10 [279 x 254] 1 [746] 12. 0 15 1595 [753] 685 [323] 1200-2000 [566-944] 0. 80 [0. 20] 40-70 [22. 2-38. 9] 180 [82. 2] C24B 223/4 x 25 [578 x 635] 153/4 x 25 [400 x 635] 170 [77. 1] 93. 2% MODEL IDENTIFICATION R Rheem G Gas Furnace F D -- 07E Heating Input Designation M C K S Modulating Design Series Prestige Series ® 90 Plus Gas Furnace Blower Size Variations Heat/Cool Fuel Code M = 11 x 7 C = Single/ Designation S = U. S. and [279 x 178 mm] Multi Zone K = 600-1200 CFM Canadian Electric R = 11 x 10 [283-566 L/s] Natural Gas Electric Ignition-- Input [279 x 254 mm] M = 1200-2000 CFM Ignition Nox Models BTU/HR Z = 12 x 11 [566-944 L/s] 06N 06E 60, 000 [17. 6 kW] [305 x 279 mm] 07N 07E 75, 000 [20. 5 kW] 09N 09E 90, 000 [26. 4 kW] 10N 10E 105, 000 [30. 7 kW] -- 12E 120, 000 [35. 2 kW] [ ] Designates Metric Conversions Rheem Manufacturing Company 3 UPFLOW MODELS MODEL RGFD06 07 09 10 12 A [445] 171/2 [445] 21 [533] 21 [533] 241/2 [622] 171/2 B 163/8 [416] 163/8 [416] 197/8 [505] 197/8 [505] 233/8 [594] C [397] 155/8 [397] 191/8 [487] 191/8 [487] 225/8 [575] 155/8 D 2 [51] 2 [51] 2 [51] 2 [51] 2 [51] E 15 [422] 15 [422] 181/2 [511] 181/2 [511] 22 [600] F [351] 1313/16 [351] 175/16 [440] 175/16 [440] 2013/16 [529] 1313/16 LEFT SIDE 0 0 0 0 0 MINIMUM CLEARANCE (IN. ) [mm] RIGHT SIDE 0 0 0 0 0 BACK 0 0 0 0 0 TOP 1 [25] 1 [25] 1 [25] 1 [25] 1 [25] FRONT 2 [51] 2 [51] 2 [51] 2 [51] 2 [51] VENT 0 0 0 0 0 [ ] Designates Metric Conversions 4 Rheem Manufacturing Company BLOWER PERFORMANCE DATA--RGFD MODELS MODEL RGFDBLOWER SIZE (D x W) IN. [W] 1/2 [373] BLOWER SPEED HIGH MED-HI MED LOW HIGH MED-HI MED LOW HIGH MED-HI MED LOW HIGH MED-HI MED LOW HIGH MED-HI MED LOW CFM [L/s] AIR DELIVERY EXTERNAL STATIC PRESSURE INCHES WATER COLUMN [kPa] 0. 1 [. 02]-0. 8 [. 20] 1200 [566] 1000 [472] 800 [378] 600 [283] 1200 [566] 1000 [472] 800 [378] 600 [283] 2000 [944] 1600 [755] 1400 [661] 1200 [566] 2000 [944] 1600 [755] 1400 [661] 1200 [566] 2000 [944] 1600 [755] 1400 [661] 1200 [566] 06 07 11 x 7 [279 x 178] 1/2 [373] 09 12 x 11 [305 x 279] 1 [746] 10 12 x 11 [305 x 279] 1 [746] 12 11 x 10 [279 x 254] 1 [746] [ ] Designates Metric Conversions GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. Primary and Secondary Heat Exchanger . . . . . . Limited Lifetime Rheem will provide a replacement RGFD Gas Furnace to the original purchaser if the Heat Exchanger fails AND if the following additional conditions are satisfied: a) Unit is still owned by the original purchaser; in the original installation location; AND b) Warranty is registered with Rheem Manufacturing Company, Air Conditioning Division within 60 Days of original installation or closing of your home. Product registration is available online at www. RheemAC. com/ register or by filling out the Warranty Registration card and returning it to the address listed on the reverse side of the card. All Other Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Five (5) Years *For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Manufacturer for a Copy. Rheem Manufacturing Company 5 ACCESSORIES--UPFLOW VENT TERMINATION KITS CONCENTRIC: Vertical/Horizontal = RXGY-E03 HORIZONTAL TWO PIPE: RXGY-D02, RXGY-D03, RXGY-D04, RXGY-G02 CONDENSATE PUMP KIT: RXGY-B01 NEUTRALIZER KIT: RXGY-A01 RETURN AIR PLENUM: RXGR-C17B RXGR-C21B RXGR-C24B EXTERNAL BOTTOM FILTER RACK: RXGF-CB EXTERNAL SIDE FILTER RACK: RXGF-CA MODEL RGFD06 07 09 10 12 FILTER RACK FILTER SIZES* INCHES [mm] RXGF-CB RXGF-CA (BOTTOM) (SIDE) 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 191/4 x 25 [489 x 635] 191/4 x 25 [489 x 635] 223/4 x 25 [578 x 635] 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] THERMOSTATS RECOMMENDED MODULATING FURNACE THERMOSTAT RHC-TST401MDMS · 7 Day 5/1/1 Programmable Modulating/Two Cool Hardwired · Works in Modulating Furnace and Modulating Furnace Dual Fuel applications (requires optional external sensor) · Bright, 12 sq. inch touchscreen display · Keypad lockout option · Hardwired · Easy, menu-driven programming · Audio prompting to ensure program change confirmation · Intuitive red/blue temperature keys · Large, easy-to-see characters · Available only through professional contractors FOSSIL FUEL KIT RXPF-F02 *PROGRAMMABLE THERMOSTAT ACCESSORIES: Adapter Plate = F61-2600 Remote F1451328 and F1451378 Sensor *Available through PROSTOCK®. [ ] Designates Metric Conversions *Filter racks are shipped without filters. Filters shipped with furnace may be used or a suitable 1" [25. 4 mm] filter. PLENUM DATA FOR "A" COILS Plenum adapters are required in some instances for use on upflow applications when plenum and furnace size do not match. FURNACE WIDTH IN. [mm] 171/2 [445] 171/2 [445] 171/2 [445] 171/2 [445] 21 21 21 [533] [533] [533] PLENUM WIDTH IN. [. . . ] (including all option ­ 278 models), the burner orifice size needs to be recalculated and verified at elevations above 2000 ft. Manifold gas pressure reduction methods to adjust for altitude may NOT be used on these models. The only method permitted on modulating furnace models is to recalculate the burner orifice size. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE RHEEM 90 PLUS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual RHEEM 90 PLUS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.