User manual REX DFM9NE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual REX DFM9NE. We hope that this REX DFM9NE user guide will be useful to you.


REX DFM9NE : Download the complete user guide (263 Ko)

You may also download the following manuals related to this product:

   REX DFM9NE (485 ko)

Manual abstract: user guide REX DFM9NE

Detailed instructions for use are in the User's Guide.

[. . . ] Gas Hob INSTRUCTION BOOKLET Models EHG 679 B - EHG 679 W 35670-3001 GB 2 Important Safety Information You MUST read these warnings carefully before installing or using the appliance. If you need assistance, contact our Customer Care Department on 01635 522799 Installation q This appliance must be installed by qualified personnel, according to the manufacturer 's instructions and to the relevant British Standards. Any gas installation must be carried out by a registered CORGI installer. Ensure that the gas and electrical supply complies with the type stated on the rating plate, located near the gas supply pipe. [. . . ] France Senlis +33 (0)3 44 62 22 22 Germany Nürnberg +49 (0)911 323 2600 Italy Pordenone +39 (0)1678 47053 Sweden Stockholm +46 (0)20 78 77 50 UK Newbury +44 (0)1635 522 799 11 Instructions for the Installer Engineer technical data OVERALL Width: Depth: Height: Weight: DIMENSIONS 580 mm. SUPPLY CONNECTIONS Gas: RC 1/2 inch (1/2 inch male) Rear right hand corner Electric: 230-240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse. This appliance complies with the EEC Directive No 89/336, concerning suppression of radio electrical interference. CUT OUT DIMENSIONS Width: 550 mm. Thickness: 40 mm. Ignition HT Spark Spark Generator Spark Gap Ispra Control's BF 50046 - 240V 0. 6 YA T 120 Fixed Rear Left Burner (semi rapid) Heat Input 1. 9 kW (6483 BTU/HR) Front Left Burner (rapid) Heat Input 2. 9 kW Natural Gas (9895 BTU/HR) 2. 7 kW L. P. G. (9212 BTU/HR) CHARACTERISTICS TYPE OF GAS BURNER RAPID (large) MAX MIN Rear Right Burner (semi rapid) Heat Input 1. 9 kW (6483 BTU/HR) Front Right Burner (auxiliary) Heat Input 1. 0 kW (3412 BTU/HR) SEMI-RAPID (medium) MAX MIN AUXILIARY (small) MAX MIN POSITION NOMINAL THERMAL POWER kW NOMINAL FLOW RATE m3/h NOZZLE REFERENCE 1/100 mm NOMINAL THERMAL POWER kW NOMINAL FLOW RATE VALUE = 37. 78 MJ/m3 Ws - 50. 7 MJ/ m3 NATURAL GAS 20 mbar 2. 9 0. 65 1. 9 0. 45 1. 0 0. 33 0. 276 119 0. 062 Adjust. 0. 181 96 0. 043 Adjust. 0. 095 70 0. 031 Adjust. VALUE = 49. 92 MJ/Kg LPG GAS 28-30/37 mbar 2. 7 0. 65 1. 9 0. 45 1. 0 0. 33 g/h 195 86 46. 8 40 137 71 32. 4 32 72 50 23. 8 28 NOZZLE REFERENCE 1/100 mm Burner Dia. Tap By-pass 1/100 mm 28 32 40 Tap colour CLASS APPLIANCE: 3 APPLIANCE CATEGORY: II2H3+ APPLIANCE GAS SUPPLY: Natural gas G20 / 20mbar Auxiliary Semi-rapid Rapid Red/Red Blue/Blue Black/Black Aeration adjustment none 12 Important safety requirements This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). Detailed recommendations are contained in the following British Standards Codes Of Practice: B. S. The hob should not be installed in a bed sitting room with a volume of less than 20 m3. If it is installed in a room of volume less than 5 m3 an air vent of effective area of 110 cm2 is required. If it is installed in a room of volume between 5 m3 and 10 m3 an air vent of effective area of 50 cm2 is required, while if the volume exceeds 11 m3 no air is required. However, if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3. 5440 Part 2 Current Edition, should be consulted to determine the requisite air vent requirements. Location The hob may be located in a kitchen, a kitchen/diner or bed sitting room, but not in a bathroom or shower room. Before making the cut out in the worktop ensure that there is a minimum distance of 55 mm. must be left between the side edges of the hob and any adjacent cabinets or walls. The minimum distance combustible material can be fitted above the hob in line with the edges of the hob is 420 mm. The minimum distance combustible material can be fitted directly above the hob is 700 mm. INSTALLATION GUIDANCE INSTRUCTIONS CLEARANCES REQUIRED WHEN FITTING THE GAS HOB WITHOUT A COOKER HOOD ABOVE INSTALLATION GUIDANCE INSTRUCTIONS CLEARANCES REQUIRED WHEN FITTING THE GAS HOB WITH A COOKER HOOD ABOVE 600 mm 700 mm 650 mm 700 420 mm 50 m 55 m mm 420 mm 100 420 mm 50 m 55 m mm 420 mm 100 mm 50 m m mm 50 m m FO 0812 FO 0813 13 Installation IMPORTANT This appliance must be installed by qualified personnel to the relevant British Standards. Any gas installation must be carried out by a registered CORGI installer. The manufacturer will not accept liability, should the above instructions or any of the other safety instructions incorporated in this book be ignored. On the end of the shaft, which includes the GJ 1/2" threaded elbow, adjustment is fixed so that the washer is fitted between the components as shown in the diagram. Screw the parts together without using excessive force. FO 0814 Gas Connection Connection to the gas supply should be with either rigid or semi-rigid pipe, i. e. The connection should be suitable for connecting to RC 1/2 (1/2 BSP male thread). When the final connection has been made, it is essential that a thorough leak test is carried out on the hob and installation. [. . . ] However a detailed visual inspection should reveal evidence of burning around the fault. Inlet wiring faulty. Rectify any fault. Isolate appliance and carry out: B: Insulation check. Rectify any fault including replacing fuses as necessary. 18 Ignition System / Gas Ignition Ignitor does not spark YES Check gas supply at burner NO Check plug top fuse and replace if necessary Light burner manually Check polarity and earth continuity of supply point Check by pass simmer adjusted Check earth continuity of appliance Check position of the electrode Check continuity from 'N' on the mains connector block and "O" on the ignitor unit Check continuity from the tip of each electrode to the terminals 1 to 4 on the ignitor unit Check fitting of burners Check continuity from 'L' on the mains connector block and the taps ignition switches Check for breaks in the insulation of the HT leads Check continuity from ignition switches connector to ignitor unit Change the taps ignition switches Change the ignitor unit 19 Commissioning When the hob has been fully installed it will be necessary to check the minimum flame setting. - Set the gas tap to the MIN flame position then turn the control knob from MIN to MAX several times. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE REX DFM9NE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual REX DFM9NE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.