User manual REVOX RECONNECT M200 DOMOTIC INTERFACE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual REVOX RECONNECT M200. We hope that this REVOX RECONNECT M200 user guide will be useful to you.


REVOX RECONNECT M200 DOMOTIC INTERFACE: Download the complete user guide (242 Ko)

You may also download the following manuals related to this product:

   REVOX RECONNECT M200 DOMOTIC INTERFACE (1054 ko)

Manual abstract: user guide REVOX RECONNECT M200DOMOTIC INTERFACE

Detailed instructions for use are in the User's Guide.

[. . . ] If you want flexibility of installation, REVOX recommends the use of the slotted holes on the sides. You should cut out the drilling template found on page 16, hold it at the required position and mark the holes for the screws. Now you can screw the Domotic interface on the wall or your selected installation location, with the screws provided. Slotted hole 2 M200 Interface M Series Connection plan Connection to the M 5 1 Connection to further external M 5 1 m o d u l e s RS 232 serial interface M51 connection activity display Serial interface activity display Setup key IR-/ wall-mounted remote control Variable voltage output Input B Input A Relay B Relay A 3 M200 Interface M Series Connection: M200 with M 5 1 Socket: M51 LINK IN The M200 Domotic interface is connected to the M51 LINK socket on the back of the M51 with the telephone cable supplied. [. . . ] If a source is disabled through the Remote menu, it will not be activated, even when it is selected in the input option. Further information on this topic can be found in the M51 Operating Manual in the Introduction chapter, in the description of the remote function. Control example The switching diagram below, shows you how can activate the Inputs A and B with two keys. Key control: INPUT A/B 6 M200 Interface M Series Connection: M200 Relay output Socket: Relay A B The two relays each offer 5 options that can be selected with the Input and Input softkeys. The Options menu is called by pressing the Setup key on the Domotic interface. Using the softkeys you can access page #2, which gives the following display on the M 5 1 : Function Remote The relays are controlled through the remote control. This function can be used to roll out a projector screen or to close window blinds. 2 The required option can be selected from an option loop: Remote Open Close Power On/Off Video On/Off Please note The switching voltage may not exceed 42 volts. Further information can be found in the Technical data chapter. 7 M200 Interface M Series Connection: M200 Voltage ramp Socket CONTROL: OUTPUT Using the OUTPUT, you can control the output voltage with the remote control, giving a variable voltage between 0 and 10 volts. This voltage ramp could be used, for example, to set the dimmer control of a lighting system to a desired level. Please ensure that you use the correct polarity when setting up as otherwise you might damage your equipment. Connection: M200 with IR controller Socket CONTROL: IR- LINK The connection to an IR receiver or a wall-mounted remote control is done through the 3-pin, screw-fixable Phoenix plug connection. REVOX recommends the use of a 2-core screened cable (microphone cable), where the screening is used as ground. This cable may be a maximum of 30 metres in length. Please ensure that you use the correct polarity when setting up as otherwise you might damage your equipment. 20V (DC) IN IR Signal Ground The maximum number of IR receivers that can be switched in parallel per M200 is 5 The voltage (+ , - ) on the IP LINK can be used to control the CONTROL: INPUT A B inputs. 8 M200 Interface M Series Setup key Using the Setup key, you can call the Domotic menu, which appears in the M51 display. Setup #1 ­ Input A/B Menu: Voltage input Display: Control Input A/B Please refer to page 5, Control Input A/B chapter for a description. Using the Softkeys you can get to pages #1 - #4 Setup #2 ­ Relays A/B Menu: Voltage input Display: Func. Relays A/B Please refer to page 7, Relay A B chapter for a description. 9 M200 Interface M Series Setup #3 - Address Setup #3- Source Menu: Address Display: Remote Address Selection of the addresses that the M200 interface accepts for communication. Address Light (30) Local (19) Both (30+19) Menu: Source Display: Remote Source Selection of the (IR) sources that the M200 interface accepts as data suppliers. This M-200 only Accepts only sources that are directly connected to the M200's IR Link, e. g. . also a M51 or an additional M200 interface. Sender SRC 2000 remote control Wall-mounted remote control Combination 10 M200 Interface M Series Setup #4 - Slot Setup #4 - Port Menu: Slot address Display: Slot Address If an additional M200 or an other external M series interface is connected, different addresses should be given through the slot selection. Slot address : #11 or #12 Menu: RS232 selection Display: Serial Port Mode The function of the M200 serial interface can be configured for different applications. the following functions are available: RS-232 Link PC control for the M 5 1 RS-232 Filtered REVOX-specific RS232 interface protocol REVOX Plasma In this configuration, an additional menu page, Setup #5 is accessible, which enables a selectable switch-on of the REVOX Plasma, dependant on the selected M51 source. 11 M200 Interface M Series Setup #5 - REVOX Plasma-TV As well as the selection of the video input on the Plasma TV for DVD and TV, the control can, for example, be used for a SAT received. The picture signal for this receiver is connected to the SVideo input on the Plasma TV and the sound is reproduced through the optical digital input Optical on the M51. [. . . ] Auto Standby: OFF After the Plasma TV has been switched on, it remains on permanently until the M51 is switched off, irrespective of which audio source is selected at the M51. 14 M200 Interface M Series Technical data Relay: A - B Switching voltage Max. switching current with - Alternating current (AC): - Direct current (DC): max. 42 Volt 8 Ampere (ohmic or inductive load) 8 Ampere (ohmic load) 4 Ampere (inductive load) INPUT: A - B Max. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE REVOX RECONNECT M200




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual REVOX RECONNECT M200 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.