User manual REVOX RECONNECT BROCHURE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual REVOX RECONNECT. We hope that this REVOX RECONNECT user guide will be useful to you.


REVOX RECONNECT BROCHURE: Download the complete user guide (606 Ko)

You may also download the following manuals related to this product:

   REVOX RECONNECT BROCHURE (608 ko)

Manual abstract: user guide REVOX RECONNECTBROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] AC current face gives a return message to the house management system in order to show the Max. Thus, the Revox World can be mirrored on practically every primary control system, whether that is an IT system, an EIB bus INPUT A-B or some other control system. Input voltage The Re:connect M200 can also carry out secondary control duties such as dimming Threshold voltage the lights or lowering the blind when a DVD is being played or muting the M51 Input resistance when the telephone rings. OUTPUT Output voltage Output current This interface fulfils a whole range of tasks. [. . . ] This allows PCs or Palmtops to access and control the Revox system, through a WLAN as well of course. A constituent part of the Re:connect M202 is the Re:control M230 software for Windows 2000/XP or the Re:control M231 for Windows CE for Palmtops. Both softwares show the Re:system M51 display 1:1, guaranteeing you uniform operation. Using the Re:control software, the Revox Multiroom system can also access all additional rooms from one central location. Other house management systems that have their own IP address can also control the Revox system through the M51 Link protocol. 140 x 65 x 40 mm (W x H x D) 250 g 100m (M202-M51) M204 Re:connect M204 ir Technical data Dimensions Revox offers a wide choice of different IR receivers; flange-mounting for integration into furniture, in a small aluminium housing for positioning on a shelf, for example, M204 Aluminium housing (incl. cable) in kit form for assembly into light switch housings or for building into Revox build-in M204 Flange speakers. The Re:connect M204 ir can be used everywhere, where a discrete and unobtrusive installation is called for. Connection options If required, Revox can deliver the Re:sound I inwall speaker with a Re:connect Re:connect M200 M204 IR receiver already integrated. Commands are sent to the Re:system M51 using the Re:control M207 or another Revox remote control unit. This type of IR Re:connect M201 receiver is particularly useful in external applications as it is completely hidden Re:connect M219 behind the metal grille. The Re:connect M204 ir is always used if the Re:system M51 source management is installed concealed and the integrated IR receiver cannot be reached or if control from an additional room in the Revox Multiroom system should only be done using a remote control. 30 x 30 x 55 mm (W x H x D) 30 mm external diameter 20 mm drilling diameter M219 Re:connect M219 Amplifier part Music power Every additional room in the Revox Multiroom system needs a Re:connect M219 Additional room amplifier. This is connected to the Multiroom network with CAT7 Frequency response cable and then when requested, the Re:system M51 source management makes the Suppression factor audio signal available to the corresponding room. Harmonic distortion The Re:connect M219 has two powerful outputs with 2 x 100 watt power in Class D technology. These outputs developed by Revox produce audio data equivalent to that produced by analogue outputs, enabling you to provide sound for larger rooms General M219 data without any problems. Supply voltage The Re:control M217 or M218 jung, feller or gira control units are also connected to Fuse rating the Re:connect M219. They give you an intuitive and uniform operation whilst at Power consumption: the same time giving feedback about the active sources. The tuner station name, the - Operation number of the track currently being played from a CD or, when you are using a Re:source M37 or M57 audio server, even the name of the artist and the track can all be called up. - Standby Up to three local sources can be connected in each room using the Re:connect M219, Operating conditions which are then only available in the corresponding room. [. . . ] Unweighted signal-to-noise ratio Channel separation Distortion factor (THD) Signal amplification Technical data Video data Video bandwidth Distortion factor SN ratio Up to 10 MHz/± 3 dB (HDTV-enabled) < 0. 1 % > 60 dB (typ. 1 Vpp) > 70 dB < 0. 02 % 1 Summary Re:connect M51 interfaces Re:system M51 source management offers a completely new concept in Home Entertainment. It can be integrated with other systems through the Re:connect interfaces, ranging from the connection of video and audio sources right up to integration into complex IT or house management systems. Re:system M51 source management outputs are offered as analogue or digital versions. Dominating Entertainment. Renowned for its unique design and ingeniously constructed products, the Revox brand offers the ultimate in multi-system compatibility, adhering to the simple underlying philosophy that whatever the function, whatever the technology, anything is possible. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE REVOX RECONNECT




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual REVOX RECONNECT will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.