User manual RAYMARINE ST60 MAXIVIEW

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual RAYMARINE ST60 MAXIVIEW. We hope that this RAYMARINE ST60 MAXIVIEW user guide will be useful to you.


RAYMARINE ST60 MAXIVIEW : Download the complete user guide (530 Ko)

Manual abstract: user guide RAYMARINE ST60 MAXIVIEW

Detailed instructions for use are in the User's Guide.

[. . . ] 3 Chapter 2: Remote Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2. 1 SeaTalk Socket Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2. 2 Mounting/Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The MaxiView repeater can be mast or cockpit mounted on sailing yachts using one of our custom Autohelm 2-unit (D186) or 4-unit (D184) mounting pods. When used in a full SeaTalk system the ST60 MaxiView can display: · Water Depth · Deep Alarm Warning · Shallow Alarm Warning · Sea Temperature · Current Boat Speed · Average Speed · Timer · Maximum Speed · Trip Log · Total Log · Current/Locked Magnetic Heading · VMG · True and Apparent Wind Direction · True and Apparent Wind Speed · Wind Beaufort Strength · Heading on Next Tack iv ST60 MaxiView Instrument Owner's Handbook If the boat's system contains a radio navigation receiver (with SeaTalk output or an NMEA 0183 interface), the following information is also available: · Speed Over Ground · Course Over Ground · Bearing to Waypoint · Cross Track Error · Latitude (current position) · Longitude (current position) · Time and date (if available from navigation receiver) · Estimated Time of Arrival at Waypoint · Tidal Vector · Velocity Made Good Over Ground · Velocity Made Good to Waypoint D1048-3 Introduction v Package contents The ST60 MaxiView contains the following items: · Item 1 ST60 MaxiView instrument. · Item 7 Dealer list. 7000/INSTRUMENT MOUNTING TEMPLATE 1 4 2-HOLES DRILL 5mm (. 197") DIA 1-HOLE DRILL 50. 8mm (2") DIA 2 5 3 SeaTalk ST60 MaxiView Owner's Handbook Worldwide Distributors 6 7 D1049-4 vi ST60 MaxiView Instrument Owner's Handbook Chapter 1: Installation 1 Chapter 1: Installation 177. 8 mm (7 in) 38. 75 mm (1. 5 in) 24 mm (0. 95 in) 110 mm (4. 33 in) D1050-3 1. 1 Siting The ST60 MaxiView can be mast, helm or cockpit/bulkhead mounted. When mast or helm mounting the MaxiView requires a custom Autohelm mast or stormrail mounting pod: 2 unit Mastpod ­ D186 4 unit Mastpod ­ D184 Single unit ST60 Helmpod ­ D171 Note: Installation procedures for helm and mast mounting are covered in the Instrument Pod handbook. Site the MaxiView where it is: · easily readable by the helmsman. · accessible from behind for ease of installation and cable running. Note: To prevent the accumulation of moisture, the ST60 MaxiView breathes through a small vent in the connector boss. The rear of the MaxiView must, therefore, be sited where it is protected from possible contact with water. The ST60 MaxiView is fitted with a foam gasket that forms a watertight seal between the rear case and the installation face. 2 ST60 MaxiView Instrument Owner's Handbook 1. 2 Mounting procedure (cockpit/bulkhead) 3 2 1 2 4 D1051-3 1 Connector boss gasket 2 Fixing studs 3 Thumb nuts 4 Sealing 1. Make sure the surface to which the MaxiView is to be mounted is smooth, flat and clean. Use the template (supplied) to mark the centres for the fixing studs (2) and the connector boss (1). Note: To allow protective covers to be fitted, adjacent MaxiView instruments should have at least 6 mm (1/4 in) gap between them. Using a 60 mm (2 3/8 in) diameter cutter, drill a hole for the connector boss (1). Install the MaxiView in the chosen location and secure with the thumb nuts (3). Also, do not use silicone grease/sealants as an additional method of sealing - these expand and may, if applied to the seal attached to the rear case, distort the MaxiView casing. 1. 3 Bracket Mounting As an alternative to bulkhead mounting, the ST60 MaxiView can, be bracket mounted using the Raymarine mounting kit (Catalogue No. D130). Chapter 1: Installation 3 D1327-2 1. 4 Flush Mounting A flush mounting kit is available for situations where a low-profile installation is required or more desirable. E25017). ST 60 D1326-3 1. 5 Power supply Power for the ST60 MaxiView is taken from the SeaTalk bus. 4 ST60 MaxiView Instrument Owner's Handbook Cable Mast Deck Junction box Keel D671-3 The SeaTalk cable from the MaxiView pod should be connected to the cable tail of the last instrument in the existing SeaTalk system. Chapter 2: Remote Installation 5 Chapter 2: Remote Installation 2. 1 SeaTalk Socket Installation The MaxiView remote controller (A25006) is SeaTalk compatible and controls the MaxiView instruments via the SeaTalk bus. The plug comes ready assembled to the remote cable and the socket can be mounted in the cockpit area or anywhere a remote control is required. When correctly installed the SeaTalk socket is fully waterproof and can be situated in an exposed location. Cabling The bulkhead socket is wired to the bus using a SeaTalk extension cable (Cat. This can either be connected to a cable that links instruments in the nav area to those in the cockpit, or connected directly to the spare SeaTalk tail on the last instrument or autopilot control unit (also using D131). D1094-2 D1095-2 6 ST60 MaxiView Instrument Owner's Handbook 2. 2 Mounting/Cabling The socket is assembled as follows: 1. Apply the self adhesive template to the bulkhead at the selected location. Carefully drill an 18 mm (23/32 in) clearance hole and two 2. 4 mm (3/32 in) pilot holes. [. . . ] Move the pointer back to SCREEN and select the next screen number by holding down DEPTH for 1 second. Note: The selected screen can be viewed at any time by pressing DEPTH momentarily to move the arrow to VIEW and then pressing DEPTH for 1 second. As well as being able to view the selected screen, it may also be cleared by pressing DEPTH momentarily to move the arrow to CLEAR and then pressing DEPTH for 1 second. 5. 2 Intermediate Calibration NAV 5 seconds WIND SOFTWARE VERSION SECURITY* * The security system is not supported by other ST60 instruments, and therefore should NOT be switched on at the ST60 MaxiView. D1325-3 Chapter 5: Calibration 27 5. 3 Extended Calibration Extended calibration contains a calibration on/off feature, damping menus and a boat show program. Calibration On/Off This feature is designed to protect your customised basic calibration settings. Once it is switched on, access is restrained to the extended calibration menu only. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE RAYMARINE ST60 MAXIVIEW




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual RAYMARINE ST60 MAXIVIEW will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.