User manual RANE RCP 3

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual RANE RCP 3. We hope that this RANE RCP 3 user guide will be useful to you.


RANE RCP 3 : Download the complete user guide (218 Ko)

Manual abstract: user guide RANE RCP 3

Detailed instructions for use are in the User's Guide.

[. . . ] DATA SHEET / MANUAL RCP 3 and RCP 4 ROOM COMBINING PANELS RCP 3 RCP 4 General Description Rane has preprogrammed into the SRM 66 a room combining mode which makes setting up a 3 or 4 room combining system a quick task. The RCP 3 (three-room combining panel) and RCP 4 (four-room combining panel) are user friendly control accessories for the SRM 66 Splitter Router Mixer and SR1L Smart Digital Remotes. To create a room combining system, the installer only has to connect the RCP 3 (or RCP 4) and 3 (or 4) SR 1L's to an SRM 66. [. . . ] Connect the RCP 3 (or RCP 4) and the SR 1L Remotes to the SRM 66 as shown on the back page of this data sheet. On the front panel of the SRM 66, use the Page (upper) Buttons to scroll to the Memory Edit Page: Mem[n]* Memory [n] Stored!In approximately 10 seconds, the SRM 66 will be in the RCP Room Combining Mode. The RCP mode of the SRM 66 uses the first 8 Memories for the room combining presets. There are 8 MRP (Memory Recall Ports) for recalling various Memories through contact closures. MRP contacts 1, 2, & 3 have been reserved for room combining presets (Memories 1-8). MRP contacts 4-8 are programmed to recall Memories 20-24 when in RCP mode. The RCP 3 uses MRP contacts 1 & 2, and the RCP 4 uses MRP contacts 1, 2 & 3. See Table 1 for details. Memories are recalled by connecting MRP terminals and binary combinations of terminals to COM. Wiring Connections When wiring to Euroblocks, a minimum wire gauge of 22 is preferred for reliability. If the ground or shield wire is left shorter, it acts as a strain relief for the other wires. Cable with a flexible jacket is easier to use and less likely to damage the connections. Fully insert each wire in the appropriate socket and tighten the screw. WIRE TYPES Variations in wire type do not greatly affect the performance of the remote controls. You may use 3- or 4- conductor unshielded remote control signal cable for shorter runs (less than 200 ft. ) or 4-conductor (2 pair) shielded remote control signal cable (use the shield as the GND return) for longer runs (200 to 1000 ft. ). [. . . ] Note that the last SR 1L in each chain must have its TERMINATE switch ON. Set preceding switches to OFF. ©Rane Corporation 10802 47th Ave. W. , Mukilteo WA 98275-5098 TEL (425)355-6000 FAX (425)347-7757 WEB http://www. rane. com Data Sheet-4 All features & specifications subject to change without notice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE RANE RCP 3




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual RANE RCP 3 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.