User manual RANE PEQ 55

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual RANE PEQ 55. We hope that this RANE PEQ 55 user guide will be useful to you.


RANE PEQ 55 : Download the complete user guide (2435 Ko)

You may also download the following manuals related to this product:

   RANE PEQ 55 DATASHEET (446 ko)
   RANE PEQ 55 SETTING TEMPLATES (79 ko)
   RANE PEQ 55 SETTINGS TEMPLATES (79 ko)

Manual abstract: user guide RANE PEQ 55

Detailed instructions for use are in the User's Guide.

[. . . ] You may use any combination of Outputs simultaneously if desired, but don't try to save a few bucks by plugging multiple sources into the Inputs and expecting them to mix -- they won't. Polarity convention on the XLR jacks is pin 2 positive, pin 3 negative and pin 1 shield (chassis ground). With the wiring out of the way it's time to polish your golden ears and start making adjustments. Fire up some music and adjust the input and output LEVELs for good headroom and optimum signal-to-noise. [. . . ] Each Hz multiplier covers a 4 octave range: x0. 1 operates from 12. 5 Hz to 200 Hz x1 operates from 125 Hz to 2 kHz x10 operates from 1. 25 kHz to 20 kHz Individual switches BYPASS each filter without affecting the others. Individual OL (overload) warning indicators light at 0 dBFS (digital clipping). Low Shelf Filters A1 and B1 include a LOW SHELF mode. When the LOW SHELF switch is in, the yellow indicator is lit and the filter is in LOW SHELF mode. Settings below 25 Hz default to 25 Hz. +14 +12 +10 +8 +6 +4 +2 d0 B u -2 -4 -6 -8 -10 -12 -14 -16 -18 -20 -22 -24 20 50 100 200 500 Hz 1k 2k 5k 10k 20k High Shelf Filters A5 and B5 include a HIGH SHELF mode. When the HIGH SHELF switch is in, the yellow indicator is lit and the filter is in HIGH SHELF mode. The BW control has no effect in HIGH SHELF mode. +14 +12 +10 +8 +6 +4 +2 d B u 0 -2 -4 -6 -8 -10 -12 -14 -16 -18 -20 -22 -24 20 50 100 200 500 Hz 1k 2k 5k 10k 20k Tone controls Independent, 3-band TONE controls are provided for each channel. Cut Filters 2nd-order Butterworth LOW- and HIGHCUT FILTERS are provided for each channel. Only the A-channel controls are active in 10-BAND mode. +10 +5 Low +6, Mid `0', Hi +6 Low `0', Mid +6, Hi `0' d b u 0 -5 -10 -15 -20 -25 -30 -35 -40 Low Off, Mid `0', Hi Off 20 50 100 200 500 Low `0', Mid Off, Hi `0' Hz 1k 2k 5k 10k 20k +10 +5 d b u 0 -5 -10 -15 -20 -25 -30 -35 -40 20 50 100 200 500 Hz 1k 2k 5k 10k 20k Manual- In and Out Level controls LEVEL controls serve three purposes, with the assistance of the In and Out Meters: 1. Adjust the OUT signal level to compensate for changes in signal level due to filter boost/cut settings. To easily adjust sensitivity without affecting the output signal level, grasp the IN and OUT controls and move them together. In and Out Meters IN and OUT Meters are peak responding and indicate signal level in dBu. If the rear panel switch is set to BYPASS ALL, all filters and level controls are bypassed. If this switch is set to BYPASS FILTERS, only the filters are bypassed. An automatic relay bypass hardwires the Inputs to the Outputs when the POWER is off. BYPASS ALL FILTERS (rear panel switch) A / B control switches A / B switches determine which set of controls is used by channel A and channel B. There is a 100 ms mute to allow the filters to settle when the A/B control switch is changed. A / B control switches allow: · Independent, dual mono operation · A/B setting comparison · 5-Band linked stereo operation (A or B controls affect both channels) · Two "analog memories" See the Applications section for example uses of the A / B switches. 10-Band mode / 5-Band mode In 5-BAND mode, the PEQ 55 provides two independent 5-band parametric equalizers. A or B controls may be used to control each channel as described above. In 10-BAND mode, both channels are stereo linked and operation is as follows: 1. All 10 filters affect both A and B Outputs, permitting mono or stereo linked operation. [. . . ] Power connector The PEQ 55 uses a universal internal switching power supply that accepts 100 to 240 VAC at 50 to 60 Hz, allowing it to work in most countries. Output B uses the B set of controls. EQ B 5-BAND IN -12 -6 -3 0 +3 +6 +12 OL OUT A If your mixer uses TRS Insert jacks (unbalanced), we recommend using cable wired as shown below. BYPASS A PEQ 55 PARAMETRIC EQUALIZER RED 1-CONDUCTOR SHIELDED CABLE RED SHIELD R T SEND EQ B IN T = SEND R = RETURN S = SHIELD Ring & Sleeve = Both tied to Shield RED SHIELD RED SHIELD Ring = No connection -12 -6 -3 0 +3 +6 +12 OL OUT B T R 1-CONDUCTOR SHIELDED CABLE T RETURN POWER Using the A / B Controls to Switch Between Two Different EQ Settings From Mixing Console Connect INPUT B for Linked Stereo 5-Band Operation BW 1 6 12 . 5 1 INPUT A GAIN 0 -6 -24 LOW SHELF OL FREQUENCY 500 250 125 1k 2k GAIN 0 1. 5 2 -6 -24 6 12 BW 1 GAIN 0 1. 5 2 -6 -24 6 12 BW 1 GAIN 0 1. 5 2 -6 -24 6 12 BW 1 GAIN 0 1. 5 2 -6 -24 6 12 HIGH SHELF OL FREQUENCY 500 250 125 1k 2k . 5 1 BW 1 1. 5 2 TONE + 6 CUT FILTERS + 6 240 120 5k 7k 10k 14k 20k LOW HIGH + 6 240 120 5k 7k 10k 14k 20k 12 0 + 12 12 0 + 12 LEVEL 12 BYPASS A 10-BAND OL FREQUENCY 500 . 5 1 OL FREQUENCY 500 . 5 1 OL FREQUENCY 500 . 5 1 EQ 0 B 5-BAND IN dB /12 oct dB /12 oct dB /12 oct dB /12 oct dB /12 oct A1 BYPASS A2 Hz x0. 1 x1 x10 BW 1 BYPASS 250 125 1k 2k A3 Hz x0. 1 x1 x10 BW 1 BYPASS 250 125 1k 2k A4 Hz x0. 1 x1 x10 BW 1 BYPASS 250 125 1k 2k A5 Hz x0. 1 x1 x10 BW 1 0 0 60 30 -12 -6 -3 0 +3 +6 +12 OL OUT A BYPASS Hz x0. 1 x1 x10 BW 1 LOW + 6 MID HIGH 15 12 + IN OUT 12 EQ 0 B IN -12 -6 -3 0 +3 +6 +12 OL OUT 12 + LEVEL POWER BYPASS A GAIN 0 -6 -24 6 12 LOW SHELF OL FREQUENCY 500 250 125 1k 2k . 5 1 GAIN 0 1. 5 2 -6 -24 6 12 GAIN 0 1. 5 2 -6 -24 6 12 GAIN 0 1. 5 2 -6 -24 6 12 GAIN 0 1. 5 2 -6 -24 6 12 HIGH SHELF OL FREQUENCY 500 250 125 1k 2k . 5 1 PEQ 55 PARAMETRIC EQUALIZER OL FREQUENCY 500 . 5 1 OL FREQUENCY 500 . 5 1 OL FREQUENCY 500 . 5 1 1. 5 2 dB /12 oct dB /12 oct dB /12 oct dB /12 oct dB /12 oct 0 0 60 30 B1 BYPASS B2 Hz x0. 1 x1 x10 BYPASS 250 125 1k 2k B3 Hz x0. 1 x1 x10 BYPASS 250 125 1k 2k B4 Hz x0. 1 x1 x10 BYPASS 250 125 1k 2k B5 Hz x0. 1 x1 x10 BYPASS B Hz x0. 1 x1 x10 TONE 15 CUT FILTERS OUTPUT A OUTPUT B BYPASS A 10-BAND BYPASS A 10-BAND To crossovers, amplifiers, speakers EQ B 5-BAND IN -12 -6 -3 0 +3 +6 +12 OL OUT 5-BAND mode is selected. EQ B 5-BAND IN A . . . then switch to the B set of controls for a second EQ setting. -12 -6 -3 0 +3 +6 +12 OL OUT A Use the A set of controls for one EQ setting. . . BYPASS A PEQ 55 PARAMETRIC EQUALIZER BYPASS A PEQ 55 PARAMETRIC EQUALIZER EQ B IN EQ B IN -12 -6 -3 0 +3 +6 +12 OL OUT B -12 -6 -3 0 +3 +6 +12 OL OUT B POWER POWER Manual- PEQ 55 Settings Templates GAIN 1 . 5 1. 5 -6 6 0 1 0 1. 5 -6 6 1 0 1. 5 -6 6 1 LOW SHELF OL 1 BW . 5 GAIN OL 1 BW . 5 GAIN OL 1 BW . 5 /12 oct 2 1. 5 GAIN + 6 5k 7k 10k 14k 20k LOW HIGH + 6 240 120 1 BW + 6 240 120 0 60 30 0 0 + 12 12 GAIN HIGH SHELF BW TONE CUT FILTERS LEVEL BYPASS A 10-BAND 0 1 0 -6 1 6 /12 oct dB 2 /12 oct dB /12 oct dB -24 12 2 -24 12 2 -24 12 OL FREQUENCY 500 250 1k . 5 1. 5 -6 6 OL FREQUENCY 500 250 1k -24 500 dB 12 1 /12 FREQUENCY 1k oct 2 -24 dB 12 EQ 0 B 5-BAND IN -12 -6 -3 0 +3 +6 +12 OL OUT A1 Hz x0. 1 x1 x10 BW 1 . 5 1. 5 -6 6 0 1 0 1. 5 -6 6 1 0 1. 5 -6 6 1 125 2k 500 FREQUENCY FREQUENCY 500 250 1k BYPASS 2k 250 1k A2 BYPASS x1 x10 BW OL 1 Hz x0. 1 125 2k BYPASS x1 x10 BW OL 1 250 A3 Hz x0. 1 125 2k A4 BYPASS x1 x10 BW . 5 /12 oct 2 1. 5 A5 Hz x0. 1 BYPASS Hz x0. 1 A 12 IN OUT 12 + BYPASS A 125 2k x1 LOW + 6 MID HIGH x10 GAIN . 5 . 5 125 15 GAIN OL FREQUENCY 500 250 1k LOW SHELF BW GAIN GAIN GAIN HIGH SHELF PEQ 55 5k 7k + 12 12 EQ B 0 1 0 PARAMETRIC EQUALIZER -6 1 6 /12 oct dB 2 /12 oct dB /12 oct dB -24 12 2 -24 12 2 -24 12 OL FREQUENCY 500 250 1k . 5 1. 5 -6 6 OL FREQUENCY 500 250 1k -24 dB 500 1k 12 1 /12 FREQUENCY oct 2 -24 dB 12 B1 Hz x0. 1 x1 x10 125 2k 500 FREQUENCY 0 0 60 30 10k 14k 0 0 IN -12 -6 -3 0 +3 +6 +12 OL OUT BYPASS 2k 250 1k B2 BYPASS x1 x10 125 2k Hz x0. 1 x1 x10 125 2k BYPASS x1 x10 250 B3 Hz x0. 1 BYPASS Hz x0. 1 BYPASS Hz x0. 1 B4 TONE B5 B 15 20k CUT FILTERS 12 LEVEL 12 + POWER 125 2k x1 x10 125 GAIN 1 . 5 1. 5 -6 6 0 1 0 1. 5 -6 6 1 0 1. 5 2 -6 -24 LOW SHELF OL 1 BW . 5 GAIN OL 1 BW . 5 /12 oct GAIN BW GAIN BW GAIN 6 12 dB HIGH SHELF OL FREQUENCY . 5 1 BW 1 1. 5 /12 2 oct TONE + 6 CUT FILTERS + 6 240 120 5k 7k + 12 LEVEL 12 BYPASS A 10-BAND 0 1 0 -6 1 6 /12 oct dB 2 /12 oct dB -24 12 2 -24 12 OL FREQUENCY 500 250 1k . 5 1. 5 -6 6 OL FREQUENCY 500 250 125 2k 1k -24 500 dB 1k 12 1 /12 FREQUENCY oct 2 -24 dB 12 EQ 500 B 0 0 60 10k 0 0 5-BAND IN A1 Hz x0. 1 x1 x10 BW 1 . 5 1. 5 -6 6 0 1 0 1. 5 2 -24 -6 6 12 dB 125 2k 500 FREQUENCY BYPASS 2k 250 1k A2 BYPASS x1 x10 BW OL 1 Hz x0. 1 BYPASS 250 A3 Hz x0. 1 BYPASS A4 A5 Hz x0. 1 x1 x10 BW 1 BYPASS 250 125 1k 2k Hz x0. 1 x1 x10 GAIN 0 30 14k -12 -6 -3 0 +3 +6 +12 OL OUT A HIGH SHELF BW 1 125 2k x1 x10 GAIN . 5 /12 oct 125 15 LOW + 6 MID HIGH + 6 240 LOW HIGH 20k 12 IN 5k + 12 OUT 12 + BYPASS . 5 1. 5 -6 6 . 5 1. 5 GAIN OL LOW SHELF BW GAIN GAIN A 12 OL 1 PEQ 55 120 /12 0 1 0 PARAMETRIC EQUALIZER 7k FREQUENCY oct 2 -24 dB 12 1 -6 1 6 /12 oct dB 2 -24 12 OL FREQUENCY 500 250 1k . 5 1. 5 -6 6 OL EQ /12 B FREQUENCY oct 2 -24 500 dB 1k 12 1 /12 FREQUENCY oct 2 -24 dB 12 B1 Hz x0. 1 x1 x10 125 2k 500 FREQUENCY 0 0 60 10k 0 0 IN BYPASS 2k 250 1k B2 BYPASS x1 x10 Hz x0. 1 Hz x0. 1 BYPASS 250 B3 B4 BYPASS 500 250 125 1k 2k B5 Hz x0. 1 x1 x10 BYPASS 500 250 125 1k 2k 30 Hz x0. 1 x1 x10 14k -12 -6 -3 0 +3 +6 +12 OL OUT B TONE 125 2k x1 15 20k CUT FILTERS 12 LEVEL x10 125 12 + POWER Manual- Get out your crayons!Additional templates may be downloaded at www. rane. com/peq. html. Additional Resources Unless you truly have golden ears, most people have a hard time knowing exactly where to set each control. Goldline The TEF20 performs Time, Energy and Frequency measurements using the science of Time Delay Spectrometry (TDS) www. gold-line. com/tef/tef. htm Sia Software Company SmaartLive and SIA Acoustic Tools sound system measurement, acoustic analysis and real-time control software. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE RANE PEQ 55




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual RANE PEQ 55 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.