User manual RANE PEQ 55
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual RANE PEQ 55. We hope that this RANE PEQ 55 user guide will be useful to you.
You may also download the following manuals related to this product:
RANE PEQ 55 DATASHEET (446 ko)
RANE PEQ 55 SETTING TEMPLATES (79 ko)
RANE PEQ 55 SETTINGS TEMPLATES (79 ko)
Manual abstract: user guide RANE PEQ 55
Detailed instructions for use are in the User's Guide.
[. . . ] You may use any combination of Outputs simultaneously if desired, but don't try to save a few bucks by plugging multiple sources into the Inputs and expecting them to mix -- they won't. Polarity convention on the XLR jacks is pin 2 positive, pin 3 negative and pin 1 shield (chassis ground). With the wiring out of the way it's time to polish your golden ears and start making adjustments. Fire up some music and adjust the input and output LEVELs for good headroom and optimum signal-to-noise. [. . . ] Each Hz multiplier covers a 4 octave range: x0. 1 operates from 12. 5 Hz to 200 Hz x1 operates from 125 Hz to 2 kHz x10 operates from 1. 25 kHz to 20 kHz Individual switches BYPASS each filter without affecting the others. Individual OL (overload) warning indicators light at 0 dBFS (digital clipping).
Low Shelf Filters A1 and B1 include a LOW SHELF mode. When the LOW SHELF switch is in, the yellow indicator is lit and the filter is in LOW SHELF mode. Settings below 25 Hz default to 25 Hz.
+14 +12 +10 +8 +6 +4 +2 d0 B u -2 -4 -6 -8 -10 -12 -14 -16 -18 -20 -22 -24 20 50 100 200 500 Hz 1k 2k 5k 10k 20k
High Shelf Filters A5 and B5 include a HIGH SHELF mode. When the HIGH SHELF switch is in, the yellow indicator is lit and the filter is in HIGH SHELF mode. The BW control has no effect in HIGH SHELF mode.
+14 +12 +10 +8 +6 +4 +2 d B u 0 -2 -4 -6 -8 -10 -12 -14 -16 -18 -20 -22 -24 20 50 100 200 500 Hz 1k 2k 5k 10k 20k
Tone controls Independent, 3-band TONE controls are provided for each channel. Cut Filters 2nd-order Butterworth LOW- and HIGHCUT FILTERS are provided for each channel. Only the A-channel controls are active in 10-BAND mode.
+10 +5
Low +6, Mid `0', Hi +6
Low `0', Mid +6, Hi `0'
d b u
0 -5
-10 -15 -20 -25 -30 -35 -40
Low Off, Mid `0', Hi Off
20 50 100 200 500
Low `0', Mid Off, Hi `0'
Hz
1k 2k 5k 10k 20k
+10 +5
d b u
0 -5
-10 -15 -20 -25 -30 -35 -40
20
50
100
200
500
Hz
1k
2k
5k
10k
20k
Manual-
In and Out Level controls LEVEL controls serve three purposes, with the assistance of the In and Out Meters: 1. Adjust the OUT signal level to compensate for changes in signal level due to filter boost/cut settings. To easily adjust sensitivity without affecting the output signal level, grasp the IN and OUT controls and move them together. In and Out Meters IN and OUT Meters are peak responding and indicate signal level in dBu. If the rear panel switch is set to BYPASS ALL, all filters and level controls are bypassed. If this switch is set to BYPASS FILTERS, only the filters are bypassed. An automatic relay bypass hardwires the Inputs to the Outputs when the POWER is off.
BYPASS ALL FILTERS
(rear panel switch)
A / B control switches A / B switches determine which set of controls is used by channel A and channel B. There is a 100 ms mute to allow the filters to settle when the A/B control switch is changed. A / B control switches allow: · Independent, dual mono operation · A/B setting comparison · 5-Band linked stereo operation (A or B controls affect both channels) · Two "analog memories" See the Applications section for example uses of the A / B switches. 10-Band mode / 5-Band mode In 5-BAND mode, the PEQ 55 provides two independent 5-band parametric equalizers. A or B controls may be used to control each channel as described above. In 10-BAND mode, both channels are stereo linked and operation is as follows: 1. All 10 filters affect both A and B Outputs, permitting mono or stereo linked operation. [. . . ] Power connector The PEQ 55 uses a universal internal switching power supply that accepts 100 to 240 VAC at 50 to 60 Hz, allowing it to work in most countries. Output B uses the B set of controls.
EQ
B
5-BAND IN
-12
-6
-3
0
+3
+6 +12 OL OUT
A
If your mixer uses TRS Insert jacks (unbalanced), we recommend using cable wired as shown below.
BYPASS A
PEQ 55
PARAMETRIC EQUALIZER
RED
1-CONDUCTOR SHIELDED CABLE
RED SHIELD R
T
SEND
EQ
B IN
T = SEND R = RETURN S = SHIELD
Ring & Sleeve = Both tied to Shield RED SHIELD RED SHIELD Ring = No connection
-12
-6
-3
0
+3
+6 +12 OL OUT
B
T
R
1-CONDUCTOR SHIELDED CABLE
T
RETURN
POWER
Using the A / B Controls to Switch Between Two Different EQ Settings
From Mixing Console Connect INPUT B for Linked Stereo 5-Band Operation
BW
1 6 12 . 5
1
INPUT A
GAIN
0 -6 -24
LOW SHELF OL FREQUENCY
500 250 125 1k 2k
GAIN
0 1. 5 2 -6 -24 6 12
BW
1
GAIN
0 1. 5 2 -6 -24 6 12
BW
1
GAIN
0 1. 5 2 -6 -24 6 12
BW
1
GAIN
0 1. 5 2 -6 -24 6 12
HIGH SHELF OL FREQUENCY
500 250 125 1k 2k . 5
1
BW
1 1. 5 2
TONE + 6
CUT FILTERS + 6 240 120 5k 7k 10k 14k 20k LOW HIGH + 6 240 120 5k 7k 10k 14k 20k 12 0 + 12 12 0 + 12
LEVEL 12
BYPASS
A
10-BAND
OL FREQUENCY
500
. 5
1
OL FREQUENCY
500
. 5
1
OL FREQUENCY
500
. 5
1
EQ 0
B
5-BAND IN
dB
/12
oct
dB
/12
oct
dB
/12
oct
dB
/12
oct
dB
/12
oct
A1
BYPASS
A2
Hz x0. 1 x1 x10 BW
1
BYPASS
250 125
1k 2k
A3
Hz x0. 1 x1 x10 BW
1
BYPASS
250 125
1k 2k
A4
Hz x0. 1 x1 x10 BW
1
BYPASS
250 125
1k 2k
A5
Hz x0. 1 x1 x10 BW
1
0
0
60 30
-12
-6
-3
0
+3
+6 +12 OL OUT
A
BYPASS
Hz x0. 1 x1 x10 BW
1
LOW + 6 MID HIGH
15
12 + IN OUT 12 EQ 0 B IN -12 -6 -3 0 +3 +6 +12 OL OUT 12 + LEVEL POWER BYPASS A
GAIN
0 -6 -24 6 12
LOW SHELF OL FREQUENCY
500 250 125 1k 2k . 5
1
GAIN
0 1. 5 2 -6 -24 6 12
GAIN
0 1. 5 2 -6 -24 6 12
GAIN
0 1. 5 2 -6 -24 6 12
GAIN
0 1. 5 2 -6 -24 6 12
HIGH SHELF OL FREQUENCY
500 250 125 1k 2k . 5
1
PEQ 55
PARAMETRIC EQUALIZER
OL FREQUENCY
500
. 5
1
OL FREQUENCY
500
. 5
1
OL FREQUENCY
500
. 5
1
1. 5 2
dB
/12
oct
dB
/12
oct
dB
/12
oct
dB
/12
oct
dB
/12
oct
0
0
60 30
B1
BYPASS
B2
Hz x0. 1 x1 x10 BYPASS
250 125
1k 2k
B3
Hz x0. 1 x1 x10 BYPASS
250 125
1k 2k
B4
Hz x0. 1 x1 x10 BYPASS
250 125
1k 2k
B5
Hz x0. 1 x1 x10 BYPASS
B
Hz x0. 1 x1 x10
TONE
15
CUT FILTERS
OUTPUT A
OUTPUT B
BYPASS A 10-BAND BYPASS A 10-BAND
To crossovers, amplifiers, speakers
EQ B 5-BAND IN -12 -6 -3 0 +3 +6 +12 OL OUT
5-BAND mode is selected.
EQ
B
5-BAND IN
A
. . . then switch to the B set of controls for a second EQ setting.
-12
-6
-3
0
+3
+6 +12 OL OUT
A
Use the A set of controls for one EQ setting. . .
BYPASS
A
PEQ 55
PARAMETRIC EQUALIZER
BYPASS
A
PEQ 55
PARAMETRIC EQUALIZER
EQ
B IN
EQ
B IN
-12
-6
-3
0
+3
+6 +12 OL OUT
B
-12
-6
-3
0
+3
+6 +12 OL OUT
B
POWER
POWER
Manual-
PEQ 55 Settings Templates
GAIN
1 . 5 1. 5 -6 6 0 1 0 1. 5 -6 6 1 0 1. 5 -6 6 1
LOW SHELF OL
1
BW
. 5
GAIN OL
1
BW
. 5
GAIN OL
1
BW
. 5 /12 oct 2 1. 5
GAIN + 6 5k 7k 10k 14k 20k LOW HIGH + 6 240 120
1
BW + 6 240 120 0 60 30 0 0 + 12 12
GAIN
HIGH SHELF
BW
TONE
CUT FILTERS
LEVEL
BYPASS
A
10-BAND
0
1
0
-6
1
6 /12 oct dB 2 /12 oct dB /12 oct dB -24 12 2 -24 12 2 -24 12
OL FREQUENCY
500 250 1k
. 5
1. 5
-6
6
OL FREQUENCY
500 250 1k
-24 500
dB
12
1
/12
FREQUENCY
1k
oct
2
-24
dB
12
EQ 0
B
5-BAND IN -12 -6 -3 0 +3 +6 +12 OL OUT
A1
Hz x0. 1 x1 x10 BW
1 . 5 1. 5 -6 6 0 1 0 1. 5 -6 6 1 0 1. 5 -6 6 1 125 2k
500
FREQUENCY
FREQUENCY
500 250 1k
BYPASS
2k
250
1k
A2
BYPASS x1 x10 BW OL
1
Hz x0. 1
125 2k
BYPASS x1 x10 BW OL
1
250
A3
Hz x0. 1
125 2k
A4
BYPASS x1 x10 BW
. 5 /12 oct 2 1. 5
A5
Hz x0. 1 BYPASS Hz x0. 1
A
12 IN OUT 12 + BYPASS A
125
2k
x1 LOW + 6 MID HIGH
x10 GAIN
. 5 . 5
125
15
GAIN OL FREQUENCY
500 250 1k
LOW SHELF
BW
GAIN
GAIN
GAIN
HIGH SHELF
PEQ 55
5k 7k + 12 12 EQ B
0
1
0
PARAMETRIC EQUALIZER
-6
1
6 /12 oct dB 2 /12 oct dB /12 oct dB -24 12 2 -24 12 2 -24 12
OL FREQUENCY
500 250 1k
. 5
1. 5
-6
6
OL FREQUENCY
500 250 1k
-24
dB 500 1k
12
1
/12
FREQUENCY
oct
2
-24
dB
12
B1
Hz x0. 1 x1 x10
125 2k
500
FREQUENCY
0
0
60 30
10k 14k
0
0
IN -12 -6 -3 0 +3 +6 +12 OL OUT
BYPASS
2k
250
1k
B2
BYPASS x1 x10
125 2k
Hz x0. 1 x1 x10
125 2k
BYPASS x1 x10
250
B3
Hz x0. 1 BYPASS Hz x0. 1 BYPASS Hz x0. 1
B4
TONE
B5
B
15
20k CUT FILTERS 12 LEVEL 12 + POWER
125
2k
x1
x10
125
GAIN
1 . 5 1. 5 -6 6 0 1 0 1. 5 -6 6 1 0 1. 5 2 -6 -24
LOW SHELF OL
1
BW
. 5
GAIN OL
1
BW
. 5 /12 oct
GAIN
BW
GAIN
BW
GAIN
6 12 dB
HIGH SHELF OL FREQUENCY
. 5
1
BW
1 1. 5 /12 2 oct
TONE + 6
CUT FILTERS + 6 240 120 5k 7k + 12
LEVEL 12
BYPASS
A
10-BAND
0
1
0
-6
1
6 /12 oct dB 2 /12 oct dB -24 12 2 -24 12
OL FREQUENCY
500 250 1k
. 5
1. 5
-6
6
OL FREQUENCY
500 250 125 2k 1k
-24 500
dB 1k
12
1
/12
FREQUENCY
oct
2
-24
dB
12
EQ
500
B 0 0 60 10k 0 0
5-BAND IN
A1
Hz x0. 1 x1 x10 BW
1 . 5 1. 5 -6 6 0 1 0 1. 5 2 -24 -6 6 12 dB 125 2k
500
FREQUENCY
BYPASS
2k
250
1k
A2
BYPASS x1 x10 BW OL
1
Hz x0. 1
BYPASS
250
A3
Hz x0. 1 BYPASS
A4
A5
Hz x0. 1 x1 x10 BW
1
BYPASS
250 125
1k 2k
Hz x0. 1 x1 x10 GAIN
0
30
14k
-12 -6
-3
0
+3
+6 +12 OL OUT
A
HIGH SHELF BW
1
125
2k
x1
x10 GAIN
. 5 /12 oct
125
15
LOW + 6 MID HIGH + 6 240 LOW HIGH
20k
12 IN 5k + 12 OUT
12 + BYPASS
. 5 1. 5 -6 6 . 5 1. 5
GAIN OL
LOW SHELF
BW
GAIN
GAIN
A 12 OL
1
PEQ 55
120
/12
0
1
0
PARAMETRIC EQUALIZER 7k FREQUENCY
oct 2 -24 dB 12
1
-6
1
6 /12 oct dB 2 -24 12
OL FREQUENCY
500 250 1k
. 5
1. 5
-6
6
OL
EQ
/12
B FREQUENCY
oct 2
-24 500
dB 1k
12
1
/12
FREQUENCY
oct
2
-24
dB
12
B1
Hz x0. 1 x1 x10
125 2k
500
FREQUENCY
0
0
60
10k
0
0
IN
BYPASS
2k
250
1k
B2
BYPASS x1 x10 Hz x0. 1
Hz x0. 1
BYPASS
250
B3
B4
BYPASS
500
250 125
1k 2k
B5
Hz x0. 1 x1 x10 BYPASS
500
250 125
1k 2k
30 Hz x0. 1 x1 x10
14k
-12 -6
-3
0
+3
+6 +12 OL OUT
B
TONE
125
2k
x1
15
20k CUT FILTERS
12 LEVEL
x10
125
12 +
POWER
Manual-
Get out your crayons!Additional templates may be downloaded at www. rane. com/peq. html.
Additional Resources
Unless you truly have golden ears, most people have a hard time knowing exactly where to set each control. Goldline The TEF20 performs Time, Energy and Frequency measurements using the science of Time Delay Spectrometry (TDS) www. gold-line. com/tef/tef. htm Sia Software Company SmaartLive and SIA Acoustic Tools sound system measurement, acoustic analysis and real-time control software. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE RANE PEQ 55
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual RANE PEQ 55 will begin.