User manual RANE MA 6S

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual RANE MA 6S. We hope that this RANE MA 6S user guide will be useful to you.


RANE MA 6S : Download the complete user guide (364 Ko)

You may also download the following manuals related to this product:

   RANE MA 6S SCHEMA (257 ko)
   RANE MA 6S BROCHURE (11242 ko)
   RANE MA 6S DATASHEET (234 ko)

Manual abstract: user guide RANE MA 6S

Detailed instructions for use are in the User's Guide.

[. . . ] With Input and Output connections completed, be sure all front panel LEVEL controls are all the way counterclockwise. Now flip the POWER switch and after hearing the relays click in after a second, notice that the READY lights come on. Slowly turn up each channel's LEVEL control to the desired gain and if all is well you should hear something pleasant. If not, re-check connections, put on a better CD, and read more of the manual. WEAR PARTS: This product contains no wear parts. Manual-1 FRONT PANEL DESCRIPTION 1 CLIP LIMIT SOA LIMIT READY BRIDGED POWER THERMAL POWER LEVEL +4 +10 4 6 +20 2 0 8 10 dBu 0 2 CLIP LIMIT SOA LIMIT READY (INACTIVE) LEVEL +4 +10 4 6 +20 2 0 8 10 dBu 0 3 CLIP LIMIT SOA LIMIT READY BRIDGED LEVEL +4 +10 4 6 +20 2 0 8 10 dBu 0 4 CLIP LIMIT SOA LIMIT READY (INACTIVE) LEVEL +4 +10 4 6 +20 2 0 8 10 dBu 0 5 CLIP LIMIT SOA LIMIT READY BRIDGED LEVEL +4 +10 4 6 +20 2 0 8 10 dBu 0 6 CLIP LIMIT MA 6S SOA LIMIT READY (INACTIVE) LEVEL +4 +10 4 6 +20 2 0 8 10 dBu 0 MULTI CHANNEL AMPLIFIER 1 2 3 4 5 6 7 POWER switch: Obediently turns the MA 6S on and off every time you poke it with your finger (or other suitable object). [. . . ] For unbalanced sources consult the included RaneNote, "Sound System Interconnection. " OUTPUTS: Connect the speaker(s) to each of the six channels by means of the Euroblock connectors with 18 to 12 AWG wire (See for Bridged operation). NORMAL/BRIDGED switch: With the switch in the out position and the red BRIDGED indicator on, the MA 6S is operating in BRIDGED mode. The MA 6S utilizes the BRIDGE switch to make internal connections between each pair of channels: 1&2, 3&4, and 5&6. Whenever a signal is connected to an odd numbered channel (say channel 1), the next even-numbered channel is driven inverted when the BRIDGE switch is activated. Connect Inputs to odd amplifier channels only (1, 3, 5), and connect speakers to the "+" terminals of each channel pair as shown in gray on the chassis silk-screen. When the BRIDGE switch is inactive, the internal connection is defeated and both channels operate independently. AC line cord: Plug this into a grounded l20 VAC AC outlet (or 230 VAC if the MA 6S is internally wired for 230 V operation). Line FUSE: For 120 volt operation, use only a 15 amp 250 volt Fast-blow (or Normal blow--not Slow blow) fuse, 1. 25" long, such as Buss ABC-15 or equivalent. Fan filter: This washable filter may easily be removed for periodic cleaning by gently pulling on the black plastic housing and then lifting it away­perform this feat with the fan off, of course. Once the filter is removed, rinse it under hot tap water; use dish soap to cut through particularly stubborn "tav sludge. " The MA 6S draws a tremendous amount of air to ensure proper cooling and resultant long term reliability. Check and clean the filter as often as necessary, especially if the THERMAL overload indicator ever comes on. IMPORTANT: Keep this filter clean to ensure proper cooling and reliability. Never remove the filter with the unit plugged in. E F 6 Manual-3 MA 6S CONNECTIONS Direct, Biamp, and Bridged Wiring 4 OHM MINIMUM 4 OHM MINIMUM 4 OHM MINIMUM 4 OHM MINIMUM 8 OHM MINIMUM DIRECT BIAMPED BRIDGED TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. RANE CORP. MA 6S TO REDUCE THE RISK OF FIRE REPLACE ONLY WITH THE SAME TYPE FUSE. DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE. CAUTION RISQUE DE CHOC ELECTRIQUE -- NE PAS OUVRIR AVIS UTILISER UN FUSIBLE DE RECHNAGE DE MÊME. DÉBRANCHER AVANT DE REMPLACER LE FUSIBLE. ACN 001 345 482 ATTENTION TO PREVENT POSSIBLE INJURY TURN UNIT OFF AND UNPLUG AC LINE CORD BEFORE REMOVING FAN FILTER GUARD FOR CLEANING. 120 V 50/60 Hz 1400 WATTS TYPICAL CAUTION 120VAC UNIT: FUSE TYPE 3AB 15A/250VAC FB 230VAC UNIT: FUSE TYPE 3AB 8A/250VAC FB FUSE FUS E US BRIDGED SPEAKER BLACK RED + 6 + ­ CHASSIS GROUND 5 + ­ ­ + + ­ 4 + ­ ­ + 3 + ­ 2 + ­ ­ + 1 SIGNAL GROUND FOR CONTINUED GROUNDING PROTECTION DO NOT REMOVE SCREW IN ­ + IN ­ + IN ­ + IN ­ + IN ­ + (NOT USED) IN ­ + INPUT OUTPUT POWER PER CHANNEL 100 WATTS / 8 150 WATTS / 4 300 WATTS / 8 CLASS 2 OUTPUT POWER PER CHANNEL 100 WATTS / 8 150 WATTS / 4 300 WATTS / 8 CLASS 2 OUTPUT POWER PER CHANNEL 100 WATTS / 8 150 WATTS / 4 300 WATTS / 8 CLASS 2 NORMAL NORMAL BRIDGED LEFT INPUT RIGHT INPUT BRIDGED INPUT AC 22B POWER MADE IN U. S. A. RANE CORP. HIGH OUT LOW OUT CHANNEL 2 IN STEREO 2-WAY SUBWOOFER SWITCH MUST BE SET TO 2-CHANNEL FOR MONO 3-WAY 160mA CLASS 2 EQUIPMENT OMIT FOR MONO SUB SYSTEM MODE STEREO MONO 2-WAY 3-WAY SUBWOOFER 2MONO SUB CHANNEL Manual-4 E F HIGH OUT LOW OUT CHANNEL 1 IN PIN 2=POSITIVE PIN 3=NEGATIVE PIN 1=CHASSIS GND MONO SUB OUT Stereo Biamped Wiring TWEETER TWEETER 8 OHM WOOFER 8 OHM WOOFER TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. RANE CORP. MA 6S TO REDUCE THE RISK OF FIRE REPLACE ONLY WITH THE SAME TYPE FUSE. DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE. CAUTION RISQUE DE CHOC ELECTRIQUE -- NE PAS OUVRIR AVIS UTILISER UN FUSIBLE DE RECHNAGE DE MÊME. DÉBRANCHER AVANT DE REMPLACER LE FUSIBLE. ACN 001 345 482 ATTENTION TO PREVENT POSSIBLE INJURY TURN UNIT OFF AND UNPLUG AC LINE CORD BEFORE REMOVING FAN FILTER GUARD FOR CLEANING. 120 V 50/60 Hz 1400 WATTS TYPICAL CAUTION 120VAC UNIT: FUSE TYPE 3AB 15A/250VAC FB 230VAC UNIT: FUSE TYPE 3AB 8A/250VAC FB FUSE FUS E US BRIDGED SPEAKER BLACK RED + BRIDGED SPEAKER BLACK RED + 6 + ­ CHASSIS GROUND 5 + ­ ­ + + ­ 4 + ­ ­ + 3 + ­ 2 + ­ ­ + 1 SIGNAL GROUND FOR CONTINUED GROUNDING PROTECTION DO NOT REMOVE SCREW IN ­ + IN ­ + IN ­ + (NOT USED) IN ­ + INPUT IN ­ + (NOT USED) IN ­ + INPUT OUTPUT POWER PER CHANNEL 100 WATTS / 8 150 WATTS / 4 300 WATTS / 8 CLASS 2 OUTPUT POWER PER CHANNEL 100 WATTS / 8 150 WATTS / 4 300 WATTS / 8 CLASS 2 OUTPUT POWER PER CHANNEL 100 WATTS / 8 150 WATTS / 4 300 WATTS / 8 CLASS 2 NORMAL BRIDGED BRIDGED AC 22B POWER MADE IN U. S. A. [. . . ] This is required in 70 or 100 volt systems when excessive bass can saturate the transformers, reduce the output, and possibly blow a fuse at high output levels. The MA 6S is shipped with these jumpers in the out position (filters defeated). CAUTION: WAIT ABOUT 15 MINUTES AFTER THE AMPLIFIER HAS BEEN POWERED DOWN BEFORE BEGINNING DISASSEMBLY, TO ALLOW THE POWER SUPPLY CAPACITORS TO DISCHARGE. Remove the bottom cover: 4 each #6 x 3/8" phillips screws on the bottom of the side rails and 12 each #6 x 1/4" phillips screws on the bottom cover. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE RANE MA 6S




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual RANE MA 6S will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.